• Home
  • Search
  • Optimize non-contrast head CT imaging tasks using multiple virtual monochromatic image sets in dual-energy spectral CT.
  • Cite Icon6
  • https://doi.org/10.3233/xst-190617Copy DOI Icon

Optimize non-contrast head CT imaging tasks using multiple virtual monochromatic image sets in dual-energy spectral CT.

  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

To demonstrate the value of optimizing non-contrast head imaging tasks by using the multiple virtual monochromatic spectral imaging (VMSI) sets in dual-energy spectral computed tomography (CT) and determine the optimal energy levels for various tasks in imaging head. This retrospective study includes 55 patients (29 women and 26 men, average age of 54.5±12.3years) who underwent non-contrast head CT in spectral imaging mode. For each patient, 21 VMSI sets from 40 to 140 keV at 5 keV intervals and 120 kVp-like image were reconstructed. Signal-to-noise ratio (SNR) for gray matter (GM) and white matter (WM), contrast-to-noise ratio (CNR) between GM and WM, subcalvarial artifact index (SAI) and posterior fossa artifact index (PFAI) were measured by placing regions-of-interest (ROIs) in nine areas of the brain. Two radiologists subjectively rated the image quality in terms of GM-WM differentiation, beam hardening artifacts in the subcalvarial space, and posterior fossa. The overall image noise was evaluated using a 5-point Likert scale. Measurement data were then statistically analyzed. The optimal energy level for viewing the supratentorial brain and reducing beam hardening artifacts in the subcalvarial space and posterior fossa was 65 keV and 75 keV, respectively. All corresponding measurements at these energy levels were significantly better than those measured at other energy levels (all P < 0.05). Dual-energy spectral CT imaging provides a set of virtual monochromatic spectral imaging and can be selected on-demand to optimize the imaging tasks in non-contrast head CT. VMSI reconstruction of dual-energy unenhanced head CT scans at 65-75 keV enables to maximize image quality.

Similar Papers
  • Research Article
  • Citations70

Differential diagnosis of osteoblastic metastases from bone islands in patients with lung cancer by single-source dual-energy CT: Advantages of spectral CT imaging

  • Jan 23, 2015
  • European Journal of Radiology
  • Yue Dong +6
  • Research Article
  • Citations58

Abdominal CT: An intra-individual comparison between virtual monochromatic spectral and polychromatic 120-kVp images obtained during the same examination

  • Jun 21, 2014
  • European Journal of Radiology
  • Yoshitake Yamada +5
  • Abstract

118 Single Source, Dual Energy CT for the Assessment of Calcified Coronary Artery Disease

  • Jun 01, 2016
  • Heart
  • Benjamin Clayton +3
  • Research Article
  • Citations6

Technical performance of a dual-energy CT system with a novel deep-learning based reconstruction process: Evaluation using an abdomen protocol.

  • Dec 29, 2022
  • Medical Physics
  • Luuk J Oostveen +6
  • Research Article
  • Citations117

Initial experience with single-source dual-energy CT abdominal angiography and comparison with single-energy CT angiography: image quality, enhancement, diagnosis and radiation dose

  • Aug 25, 2012
  • European Radiology
  • Daniella F Pinho +4
  • Research Article

Diagnostic efficiency of single source dual energy CT in differentiating adrenal adenoma from adrenal metastasis

  • Dec 10, 2023
  • BJKines National Journal of Basic &amp; Applied Sciences
  • Nagarajaiahchandandur Pradeepkumar +5
  • Research Article

Relationship between abdominal fat volume and bone base material pairs from dual-energy spectral computed tomography in young and middle-aged patients with metabolic syndrome.

  • Sep 01, 2024
  • Quantitative imaging in medicine and surgery
  • Ling Li +7
  • Research Article
  • Citations25

Combining non-contrast and dual-energy CT improves diagnosis of early gout.

  • Sep 17, 2018
  • European Radiology
  • Seul Ki Lee +4
  • Research Article

Comparative study of radiation dose and image noise between single-source fast kilo voltage peak switching technique and conventional mode on abdominal CT

  • Feb 10, 2013
  • Chinese journal of radiology
  • Xiaozhu Lin +7
  • Research Article
  • Citations7

Comparison of 270 Versus 320 mg I/mL of Iodixanol in 1 Image Assessment of Both Renal Arteries and Veins With Dual-Energy Spectral CT Imaging in Late Arterial Phase and Their Influence on Renal Function.

  • Sep 01, 2017
  • Journal of Computer Assisted Tomography
  • Kefeng Zhou +7
  • Research Article
  • Citations4

Effect of a saline flush technique for head and neck imaging in dual-energy CT: improvement of image quality and perivenous artefact reduction using virtual monochromatic imaging

  • Jul 15, 2019
  • Clinical Radiology
  • H Washio +7
  • Research Article
  • Citations45

The Value of Nonenhanced Single-Source Dual-Energy CT for Differentiating Metastases From Adenoma in Adrenal Glands

  • May 07, 2015
  • Academic Radiology
  • Ye Ju +7
  • Research Article
  • Citations5

Utility of dual energy CT angiography in the evaluation of acute non-variceal gastrointestinal hemorrhage: comparison with digital subtraction angiography.

  • Mar 20, 2023
  • Abdominal Radiology
  • Ayushi Agarwal +2
  • Research Article
  • Citations3

Artificial intelligence-based image-domain material decomposition in single-energy computed tomography for head and neck cancer.

  • Jan 14, 2024
  • International journal of computer assisted radiology and surgery
  • Yuhei Koike +6
  • Research Article
  • Citations2

Association between the quantitative characteristics of dual-energy spectral CT and cytoreduction surgery outcome in patients with advanced epithelial ovarian cancers: A prospective observational study.

  • Mar 08, 2024
  • Medicine
  • Xiaojuan Xu +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.