- Research Article
7
- 10.1080/10420159708211566
Computer simulation of Plasma Immersion Ion Implantation
- Jun 01, 1997
- Radiation Effects and Defects in Solids
- S.-M Chen + 2 more +2
Computer simulation of Plasma Immersion Ion Implantation
Plasma Immersion Ion Implantation (PIII) is a versatile material processing technique [1] , [2] with many applications in semiconductor doping and micro- and nano- fabrication [3] , as well as the surface modification of metals for improved resistance against wear and corrosion. In PIII a solid target is immersed in plasma, and negative polarity high voltage (typically 1-20 kV) pulses are applied to the target. During a negative-polarity PIII pulse electrons are repelled from the region near the target, resulting in a positive ion sheath surrounding the target; ions traversing the sheath are implanted into the solid target surface. PIII can provide uniform ion implantation with high ion fluences across broad area targets. The targets need not be planar as the plasma is conformal to the immersed target. For precision PIII processing it is important to accurately predict the implanted ion concentrations. To this end, the P2I code was developed by Bradley, Steenkamp, and Risch [4] , [5] to accurately predict PIII sheath dynamics, ion implantation currents, and total delivered ion fluences. The P2I code is an efficient implementation of the numerical solution of Lieberman's dynamic sheath model [2] with assumptions of quasi-static ion motion and sheath position, collision less ion flow, inertia less electrons and an infinite plasma ion reservoir.
Computer simulation of Plasma Immersion Ion Implantation
Computer simulation of Plasma Immersion Ion Implantation
Pulse current behavior in the presence of external magnetic field in radio frequency (RF)-inductively coupled plasma (ICP) quasi-direct current plasma immersion ion implantation
Summary form only given, as follows. In plasma immersion ion implantation (PIII) processes to fabricate silicon-on-insulator (SOI) materials such as separation by plasma implantation of oxygen (SPIMOX) and ion cut/wafer bonding, long-pulse PIII (or quasi-direct current PIII) has been shown to be more superior than conventional pulsed-mode PIII. The new process reduces the amount of the implanted ions in the near surface as well as the processing time. Our former experiments on quasi-DC and DC PIII utilize a grounded conducting grid above the sample holder to avoid plasma extinction as the plasma sheath expands. Recently, we have been successful in achieving stable operation in the long-pulse PIII mode by making the distance between the sample holder and plasma source long and the plasma density relatively high. In order to intensify the plasma discharge and produce one dominant ion species in the plasma, a weak external magnetic field (B) is generated using magnetic coils around the vacuum chamber. It is observed that the discharge is enhanced but the pulse current waveforms are significantly changed with the addition of B as well. Our results further indicate that the pulse current varies with the pressure and pulse voltage. We also observe that the magnitude of the pulse current is reduced as the pulse voltage increases in some pressure ranges. This can probably be attributed to the variation of the plasma generation volume and ion motion in the expanded sheath at different pulse voltages.
Read moreOsteoblast behavior on polytetrafluoroethylene modified by long pulse, high frequency oxygen plasma immersion ion implantation
Osteoblast behavior on polytetrafluoroethylene modified by long pulse, high frequency oxygen plasma immersion ion implantation
Read moreDevelopment and experimental study of large size composite plasma immersion ion implantation device
Plasma immersion ion implantation (PIII) overcomes the direct exposure limit of traditional beam-line ion implantation, and is suitable for the treatment of complex work-piece with large size. PIII technology is often used for surface modification of metal, plastics and ceramics. Based on the requirement of surface modification of large size insulating material, a composite full-directional PIII device based on RF plasma source and metal plasma source is developed in this paper. This device can not only realize gas ion implantation, but also can realize metal ion implantation, and can also realize gas ion mixing with metal ions injection. This device has two metal plasma sources and each metal source contains three cathodes. Under the condition of keeping the vacuum unchanged, the cathode can be switched freely. The volume of the vacuum chamber is about 0.94 m3, and maximum vacuum degree is about 5 × 10−4 Pa. The density of RF plasma in homogeneous region is about 109 cm−3, and plasma density in the ion implantation region is about 1010 cm−3. This device can be used for large-size sample material PIII treatment, the maximum size of the sample diameter up to 400 mm. The experimental results show that the plasma discharge in the device is stable and can run for a long time. It is suitable for surface treatment of insulating materials.
Read moreSurface modification of polyethylene terephthalate by plasma immersion ion implantation
Surface modification of polyethylene terephthalate by plasma immersion ion implantation
Plasma‐immersion ion implantation: A path to lower the annealing temperature of implanted boron emitters and simplify PERT solar cell processing
Ion implantation is a suitable and promising solution for the massive industrialization of boron doping, which is a crucial process step for most next‐generation solar cells based on crystalline silicon (c‐Si). However, the use of ion implantation for boron doping is limited by the high temperature (in the 1050°C range) of the subsequent activation anneal, which is essential to dissolve the boron clusters and reach a high‐emitter quality. In this work, we propose the use of plasma‐immersion ion implantation (PIII) from B2H6 gas precursor instead of the standard beamline ion implantation (BLII) technique to decrease this temperature down to 950°C. PIII and BLII boron emitters were compared with annealing temperatures ranging from 950°C to 1050°C. Contrary to BLII, no degradation of the emitter quality was observed with PIII implants annealed at 950°C along with a full activation of the dopants in the emitter. At 1000°C, emitter saturation current densities (J0e) below 21 fA/cm2 were obtained using the PIII technique regardless of the tested implantation doses for sheet resistances between 110 and 160 Ω/sq. After metallization steps, the metal/emitter contact resistances were assessed, indicating that these emitters were compatible with a conventional metallization by screen‐printing/firing. The PIII boron emitters' performances were further tested with their integration in n‐type passivated emitter rear totally diffused (PERT) solar cells fully doped by PIII. Promising results already show a conversion efficiency of 20.8% using a lower annealing temperature than with BLII and a reduced production cost.
Read moreThe effects of different anode manufacturing methods on deep levels in 4H-SiC p+n diodes
The manufacture of bipolar junctions is necessary in many 4H-SiC electronic devices, e.g., junction termination extensions and p+in diodes for voltage class >10 kV. However, the presence of electrically active levels in the drift layer that act as minority charge carrier lifetime killers, like the carbon vacancy (VC), undermines device performance. In the present study, we compared p+n diodes whose anodes have been manufactured by three different methods: by epitaxial growth, ion implantation, or plasma immersion ion implantation (PIII). The identification of the electrically active defects in the drift layers of these devices revealed that a substantial concentration of VC is present in the diodes with epitaxial grown or ion implanted anode. On the other hand, no presence of VC could be detected when the anode is formed by PIII and this is attributed to the effects of strain in the anode region. Our investigation shows that PIII can be a useful technique for the manufacture of bipolar devices with a reduced concentration of lifetime killer defects.
Read moreBio-functionalisation of polyether ether ketone using plasma immersion ion implantation
Plasma immersion ion implantation (PIII) is used here to improve the surface bioactivity of polyether ether ketone (PEEK) by modifying the chemical and mechanical properties and by introducing radicals. Modifications to the chemical and mechanical properties are characterised as a function of ion fluence (proportional to treatment time) to determine the suitability of the treated surfaces for biological applications. Radical generation increases with treatment time, where treatments greater than 400 seconds result in a high concentration of long-lived radicals. Radical reactions are responsible for oxidation of the surface, resulting in a permanent increase in the polar surface energy. The nano-scale reduced modulus was found to increase with treatment time at the surface from 4.4 to 5.2 GPa. The macromolecular Young’s modulus was also found to increase, but by an amount corresponding to the volume fraction of the ion implanted region. The treated surface layer exhibited cracking under cyclical loads, associated with an increased modulus due to dehydrogenation and crosslinking, however it did not show any sign of delamination, indicating that the modified layer is well integrated with the substrate – a critical factor for bioactive surface coatings to be used in-vivo. Protein immobilisation on the PIII treated surfaces was found to saturate after 240 seconds of treatment, indicating that there is room to tune surface mechanical properties for specific applications without affecting the protein coverage. Our findings indicate that the modification of the chemical and mechanical properties by PIII treatments as well as the introduction of radicals render PEEK well suited for use in orthopaedic implantable devices.
Read morePlasma immersion ion implantation for metallurgical and semiconductor research and development
Plasma immersion ion implantation for metallurgical and semiconductor research and development
Surface modification of metal alloys by plasma immersion ion implantation and subsequent plasma nitriding
Surface modification of metal alloys by plasma immersion ion implantation and subsequent plasma nitriding
Study of the effects of E×B fields as mechanism to carbon–nitrogen plasma immersion ion implantation on stainless steel samples
Study of the effects of E×B fields as mechanism to carbon–nitrogen plasma immersion ion implantation on stainless steel samples
Read moreChapter 4 - Surface Modification of Materials by Plasma Immersion Ion Implantation
Chapter 4 - Surface Modification of Materials by Plasma Immersion Ion Implantation
Particle-in-cell simulation of plasma immersion ion implantation (PIII) of industrial gears
Summary form only given. Plasma immersion ion implantation (PIII) has emulates conventional beam-line ion implantation in that the implantation time is independent of the sample size and large industrial components of an irregular shape can be treated relatively easily due to its non-line-of-sight characteristic. For example, due to the non-planar and periodic structure of industrial gears, conventional deposition and beam-line treatment techniques are not easily implemented. In addition, as they are used in space, typically as a component in a satellite, conventional coatings may not function desirably either, and PIII is the ideal technique in this case. In this work, we employ a theoretical model to investigate the PIII process of this important industrial component. To simulate implantation into the three-dimensional structure of a commercial gear, we work in cylindrical coordinates. Due to the periodic structure of the saw-teeth, we only need to simulate the volume of one tooth. 2D simulation along the (r-0) plane is carried out by the particle-in-cell (PIC) method. The incident dose and impact angle along the surface of the tooth are derived and our results indicate that a long implantation pulse will implant more ions at the bottom of the tooth at normal angle since the momentum of the incoming ions accelerated at the middle and end period of the pulse will overcome the attractive force from the sidewall of the tooth. Therefore, shorter pulse duration will implant the whole surface of the tooth more uniformly. We will also provide an estimation on the preferred pulse duration for different tooth dimensions.
Read moreTribological changes on SS304 stainless steel induced by nitrogen plasma immersion ion implantation with and without auxiliary heating
Tribological changes on SS304 stainless steel induced by nitrogen plasma immersion ion implantation with and without auxiliary heating
Read moreWettability and other properties of amorphous hydrogenated carbon (a-C:H) films for biomedical applications synthesized by plasma immersion ion implantation - deposition (PIII-D)
Summary form only given. Hydrogenated amorphous carbon films (a-C:H) are fabricated on silicon [100] wafers at room temperature using plasma immersion ion implantation - deposition (PIII-D). By adjusting the deposition conditions and annealing parameters (in vacuum between 400-700/spl deg/C), a series of a-C:H films with different hydrogen contents, structures, and chemical bonds are obtained. The film chemistry is investigated using micro-Raman spectroscopy. The surface morphology of the films is characterized using the atomic force microscopy (AFM). The composition is measured by Rutherford backscattering spectrometry (RBS) and elastic recoil detection (ERD). Fourier transform infrared spectroscope (FTIR) is utilized to characterize the bonding characteristics of hydrogen to carbon in the a-C:H films. The wettability of the films is investigated by contact angle measurements with different well-known liquids and physiological solutions. The surface energy and its polar and dispersive part are determined. The experimental results are used to study the influence of the different composition and structure on the wettability of the a-C:H films, a parameter that is crucial to biomedical applications.
Read more