• Home
  • Search
  • Patient-Specific Surgical Implant Using Cavity-Filled Approach for Precise and Functional Mandible Reconstruction
  • Open Access IconOpen Access
  • Cite Icon6
  • https://doi.org/10.3390/app10176030Copy DOI Icon

Patient-Specific Surgical Implant Using Cavity-Filled Approach for Precise and Functional Mandible Reconstruction

Show More
  • Abstract
  • Highlights & Summary
  • PDF
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Mandibular reconstruction is a complicated task because of the complex nature of the regional anatomy. Computer-assisted tools are a promising means of improving the precision and safety of such complex surgeries. The digital techniques utilized in the reconstruction of mandibular defects based on medical data, computer-aided-design approaches, and three-dimensional (3D) printing are widely used to improve the patient’s aesthetic appearance and function, as well as the accuracy and quality of diagnosis, and surgical outcomes. Nevertheless, to ensure an acceptable aesthetical appearance and functional outcomes, the design must be based on proper anatomical reconstruction, mostly done in a virtual environment by skilled design engineers. Mirroring is one of the widely used techniques in the surgical navigation and reconstruction of mandibular defects. However, there are some discrepancies and mismatches in the mirrored anatomical models. Hence, in order to overcome these limitations in the mirroring technique, a novel approach called the cavity-filled technique was introduced. The objective of this study was to compare the accuracy of the newly recommended cavity-filled technique with the widely used mirror reconstruction technique in restoring mandibular defects. A prominent 3D comparison technique was employed in this work, where the resected and the reconstructed mandibles were superimposed to quantify the accuracy of the two techniques. From the analysis, it can be inferred that the cavity-filled technique with a root-mean-square value of 1.1019 mm produced better accuracy in contrast to the mirroring approach, which resulted in an error of 1.2683 mm. Consequently, by using the proposed cavity-filled design, the discrepancy between the reconstruction plate and the bone contour was mitigated. This method, owing to its high precision, can decrease the number of adjustments and the time of surgery, as well as ensure a quick recovery time with better implant tissue in-growth.

Loading PDF

Similar Papers
  • Research Article

Reconstruction of mandibular segmental defects with free scapular flap: Two case reports

  • Nov 20, 2025
  • Tạp chí Y học lâm sàng Bệnh viện Trung Ương Huế
  • Nguyen Hong Loi +3
  • Research Article
  • Citations27

Immediate Reconstruction of Mandibular Defects: A Retrospective Report of 242 Cases

  • Apr 19, 2007
  • Journal of Oral and Maxillofacial Surgery
  • Zubing Li +5
  • PDF
  • Research Article
  • Citations5

Outcome Assessment after Reconstruction of Tumor-Related Mandibular Defects Using Free Vascularized Fibular Flap—A Clinical Study

  • Jan 09, 2023
  • Healthcare
  • Zahid Qayyum +10
  • Research Article
  • Citations49

Quality of Life after Free Fibula Flap Reconstruction of Segmental Mandibular Defects.

  • Sep 13, 2017
  • Journal of Reconstructive Microsurgery
  • Marcus Nyberg +6
  • Research Article
  • Citations80

Comparison of Miniplates and Reconstruction Plates in Fibular Flap Reconstruction of the Mandible

  • Dec 01, 2008
  • Plastic and Reconstructive Surgery
  • Ashley B Robey +5
  • Research Article

Reconstruction of mandibular defects using free fibula flaps with a spliced surgical template system.

  • Jun 01, 2026
  • Journal of stomatology, oral and maxillofacial surgery
  • Wei Cao +3
  • Research Article
  • Citations26

Comparison of miniplates and biodegradable plates in reconstruction of the mandible with a fibular free flap

  • Jan 20, 2015
  • British Journal of Oral and Maxillofacial Surgery
  • N.K Kim +2
  • Dissertation

Μελέτη της αγγείωσης του οστεοδερματικού κρημνού της περόνης

  • May 01, 2010
  • Δημήτριος Παπαδήμας
  • Research Article
  • Citations20

Mandibular reconstruction with the free vascularized fibular flap: utility of three-dimensional computerized tomography.

  • Feb 01, 1999
  • Journal of Reconstructive Microsurgery
  • Bernardo Leon +3
  • Conference Article
  • Citations23

Enhancement of Bone Implants by Substituting Nitinol for Titanium (Ti-6Al-4V): A Modeling Comparison

  • Sep 08, 2014
  • Narges Shayesteh Moghaddam +3
  • Research Article
  • Citations16

Custom Implant for Reconstruction of Mandibular Continuity Defect

  • Dec 13, 2017
  • Journal of Oral and Maxillofacial Surgery
  • Sang-Woon Lee +5
  • Research Article
  • Citations3

Implementation of In-house Computer-aided Design and Manufacturing for Accelerated Free Fibula Flap Reconstruction of Mandibular Defects in Cancer Patients.

  • Aug 01, 2024
  • Plastic and reconstructive surgery. Global open
  • Joakim L Lindhardt +4
  • Research Article
  • Citations77

Assessment of plate use for mandibular reconstruction: Has changing technology made a difference?

  • Oct 01, 1999
  • Otolaryngology–Head and Neck Surgery
  • Douglas W Klotch +2
  • Research Article

Precise Reconstruction of Mandibular Angle Defects Using Digital Technology-Assisted Vascularized Iliac Crest Flap Combined With Nonvascularized Iliac Bone Graft.

  • Mar 01, 2026
  • Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons
  • Yuanqing Huang +5
  • Research Article
  • Citations41

Mandibular Reconstruction With a Prefabricated Free Vascularized Fibula and Implant-Supported Prosthesis Based on Fully Three-Dimensional Virtual Planning

  • May 01, 2014
  • Journal of Craniofacial Surgery
  • Christian Freudlsperger +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.