(428) Refining the Curve: A Retrospective Review of Intraoperative Modeling During Inflatable Penile Prosthesis Placement for Peyronie’s Disease
Introduction Intraoperative manual modeling during inflatable penile prosthesis (IPP) placement for Peyronie’s disease (PD) was first described by Wilson and Delk in 1994. Early adoption was slow, partly due to the quoted 4% urethral perforation rate. In the last 30 years, modeling has been confirmed as a safe and effective technique during IPP implantation for PD. Despite widespread use, significant questions about technique persist, including the number and duration of modeling cycles, and their impact on outcomes. Comparative data among different types of IPP devices is also lacking. Objective To evaluate the efficacy and safety of intraoperative manual modeling during IPP implantation for PD. We analyzed the relationship between modeling technique (number and duration of cycles), curvature correction, device type, and clinical outcomes, including residual curvature, satisfaction, and complications. Methods A retrospective review was conducted of 93 patients who underwent IPP placement with standard intraoperative manual modeling by a single surgeon. Patients who underwent concurrent plication or grafts were excluded from the study. Variables analyzed were pre- and postoperative curvature (intraoperative and 6 months), modeling cycles and duration, device type, patient satisfaction, and complications. Modeling success was defined as <15 degrees final curvature. Logistic regression was used to identify predictors of success. Results The median preoperative curvature was 40° (range 25–75), with a median of 2 modeling cycles (range 1–4) and an average of 65 seconds per cycle (range 60–90). Postoperative curvature had a median of 10° (range 0–30). Most patients (62.0%) underwent 2 modeling cycles, while 18.5% had either 1 or 3 cycles, and only one patient required 4. Curve direction was predominantly dorsal (68.5%), followed by left (15.2%), ventral (9.8%), and right (4.4%). The vast majority (92.4%) received Coloplast Titan implants, with only a few receiving Titan Narrow Base (4.4%) or AMS 700 CX (3.3%) devices. 75% of patients achieved a curvature of <15°, with no intraoperative urethral or device injuries. At 6-month follow-up, 94.1% of patients reported satisfaction, and none required revision surgery. However, 13% showed increased curvature at 6 months postoperative compared to immediate intraoperative results. Thirty-four patients (37.0%) achieved complete straightness intraoperatively (0°), while 47.8% had a residual curve ≤15°, and 15.2% had a curvature between 16° and 30°; no patients had residual curvature >30°. In logistic regression analysis, increased BMI was significantly associated with lower likelihood of successful modeling (OR: 0.81, p=0.015). Age (OR: 0.94, p=0.062) and prior robotic-assisted laparoscopic prostatectomy (OR: 0.23, p=0.069) showed trends toward significance but did not meet statistical thresholds, likely due to limited sample size. Conclusions Manual intraoperative modeling at the time of IPP placement is a safe and effective procedure for the correction of penile curvature in PD with a 75% success rate and no intraoperative complications. Most patients experienced a marked decrease in curvature, and nearly all were satisfied at follow-up. Increased BMI was independently associated with reduced modeling success, potentially indicating a biomechanical or technical constraint in this population. Further studies are needed to refine modeling protocols and to assess long-term durability and patient-reported outcomes. Disclosure No
Read more