• Home
  • Search
  • Performance-based RCPT specification for geopolymer concrete: Modified voltage protocol and chloride resistance classification
  • https://doi.org/10.1016/j.cemconcomp.2026.106557Copy DOI Icon

Performance-based RCPT specification for geopolymer concrete: Modified voltage protocol and chloride resistance classification

Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

The reliability of the Rapid Chloride Permeability Test (RCPT), ASTM C1202, for geopolymer concrete (GPC) is often debated, particularly due to the use of 60 V and the lack of a standardised rating scale tailored to GPC. Although prior studies have noted problems with RCPT in GPC and proposed partial remedies, a fully validated framework tailored to GPC is still lacking. Standardised testing conditions and clear links between RCPT results and chloride transport behaviour remain undeveloped. To this end, this study examines the effect of applied voltage on RCPT results and recommends a modified methodology to establish a suitable rating scale for GPC. Sixty GPC mixtures, characterised by varying mix designs and strengths, were assessed, and their key properties – compressive strength, conductivity, formation factor, and charge passed – were analysed in relation to chloride diffusion coefficients. The formation factor was incorporated to normalise pore solution conductivity, thereby enabling assessment of microstructural transport behaviour. Findings confirm that voltages above 10 V often cause premature test termination; therefore, 10 V is identified as the recommended upper operating voltage for reliable RCPT testing in GPC under the investigated conditions. Following these results, performance criteria for the modified RCPT and formation factor are proposed, providing a reliable basis for assessing chloride permeability in GPC. Additionally, prescriptive requirements are outlined to guide the selection of suitable GPC mixtures for specific applications. This study delivers a validated framework for reliable RCPT use in GPC, defining voltage, rating scale, and formation factor limits to enable standardisation and adoption in design codes. • Validated guidelines established for voltage selection in RCPT tailored to GPC • RCPT performance-based testing framework developed and validated for GPC • Introduced formation factor from pore conductivity as durability indicator • Proven OPC pore chemistry–RCPT relation inapplicable to GPC

Similar Papers
  • Research Article
  • Citations3

Comparative studies of chloride permeability, conductivity and salt-ponding tests of concrete containing different admixtures

  • Jan 01, 2009
  • International Journal of Modelling, Identification and Control
  • Silvia B Uchoa +3
  • Research Article
  • Citations302

Effect of mixing proportions of concrete on its electrical conductivity and the rapid chloride permeability test (ASTM C1202 or ASSHTO T277) results

  • Oct 17, 2003
  • Cement and Concrete Research
  • Caijun Shi
  • Research Article
  • Citations1

Improvement of Geopolymer Concrete Using Synthetic Fibers

  • Dec 02, 2025
  • Advanced Materials Research
  • Chaudhary Fazeel Ahmad +5
  • Research Article
  • Citations107

Production of geopolymer concrete using natural pozzolan: A parametric study

  • Apr 06, 2016
  • Construction and Building Materials
  • Rami H Haddad +1
  • Research Article
  • Citations29

Investigation of the properties of two different slag‐based geopolymer concretes exposed to freeze–thaw cycles

  • Dec 30, 2019
  • Structural Concrete
  • Mustafa Özdal +2
  • Research Article

A mixture of coffee grounds and fly ash in cementless geopolymer concrete

  • Aug 31, 2025
  • ARPN Journal of Engineering and Applied Sciences
  • Research Article
  • Citations10

The effects of surface treatments on rapid chloride permeability tests

  • Jun 01, 2012
  • Materials Chemistry and Physics
  • Seyoon Yoon +3
  • Conference Article
  • Citations37

Bond Strengths of Geopolymer and Cement Concretes

  • Oct 27, 2010
  • Prabir Sarker
  • PDF
  • Research Article
  • Citations43

Mechanical and Durability Characteristics Assessment of Geopolymer Composite (GPC) at Varying Silica Fume Content

  • Sep 05, 2021
  • Journal of Composites Science
  • Ankur Gupta +2
  • Research Article
  • Citations5

Modelling chloride penetration resistance of Supplementary Cementitious Concrete and compressive strength with pulse velocity

  • Nov 12, 2021
  • Materials Today: Proceedings
  • Tarun Gehlot +4
  • Conference Article

Suitability of pervious geo-polymer concrete containing fly ash as road shoulder: A pilot study

  • Jan 01, 2023
  • AIP conference proceedings
  • Jagannath Patel +3
  • Research Article
  • Citations3

Incorporating crumb rubber in slag-based geopolymer: Experimental work and predictive modelling

  • Oct 28, 2024
  • Case Studies in Construction Materials
  • Ashwin Narendra Raut +9
  • Research Article
  • Citations539

Environmental impact assessment of fly ash and silica fume based geopolymer concrete

  • Jan 13, 2020
  • Journal of Cleaner Production
  • Rishabh Bajpai +4
  • Research Article

Influence of Composition Parameters, Curing Conditions and Salt Solutions on Geopolymer Concrete Properties.(Dept.C)

  • Jun 01, 2021
  • MEJ. Mansoura Engineering Journal
  • Khaled El-Sayed +2
  • Research Article
  • Citations2

A comprehensive mechanical and physico-chemical characterization of fly ash-based geopolymers

  • Dec 01, 2025
  • Results in Engineering
  • Ana Paula Ferreira +9
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.