• Home
  • Search
  • Performance evaluation of the mindview PET using GATE and STIR
  • Cite Icon2
  • https://doi.org/10.1109/nssmic.2016.8069533Copy DOI Icon

Performance evaluation of the mindview PET using GATE and STIR

  • Oct 1, 2016
  • S F Sánchez +21 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

A series of small size 22 Na point sources have been simulated using GATE, following the NEMA protocol, and applied to the geometry of a brain dedicated PET so-called MindView. The simulated scanner geometry is currently composed by one ring of 20 detector blocks with a distance of about 330 mm between opposite detectors. Each detector module includes a monolithic LYSO crystal of 50 × 50 × 20 mm 3 and a custom 12 × 12 SiPM array (TSV-type, SensL). The system defines an axial and trans-axial fields of view (FoV) of about 46 mm and 240 mm, respectively. The scintillation light inside the monolithic block was simulated in GEANT4 and is sampled following the readout scheme providing information on each SiPM array row and column (12 + 12). Out of this, three different approaches for the determination of the impact coordinates within the monolithic crystals have been considered. A first approach makes use of the center of gravity (CoG) calculation for the planar XY coordinates but the photon impact depth of interaction (DoI) is not considered. The other methods obtain the XY coordinates using the Raise to Power algorithm (RTP) before CoG calculation, with both discrete (second method) and continuous (third one) DoI information. The data is introduced on the STIR platform for reconstruction using a filtered back projection 3D re-projected algorithm (FBP3DRP). Spatial resolutions ranging in the intervals [2 mm, 3.4 mm], [2.3 mm, 3.3mm] and [2.2 mm, 2.3 mm] have been obtained for the radial, tangential and axial directions, respectively. The points sources were positioned at a radial offset of 100 mm radially out of the center.

Similar Papers
  • PDF
  • Research Article
  • Citations49

Depth of Interaction Estimation in a Preclinical PET Scanner Equipped with Monolithic Crystals Coupled to SiPMs Using a Deep Neural Network

  • Jul 10, 2020
  • Applied Sciences
  • Amirhossein Sanaat +1
  • Conference Article
  • Citations5

Development of a high resolution whole-body DOI PET system

  • Jan 01, 2007
  • Atsushi Ohtani +6
  • Conference Article
  • Citations1

Implementation of Monolithic Crystals in Stand- Alone Brain PET, and PET-MR Insert, Developments

  • Oct 01, 2017
  • Antonio J Gonzalez +4
  • Research Article
  • Citations8

Wavelength discrimination (WLD) detector optimization for time-of-flight positron emission tomography with depth of interaction information

  • Aug 12, 2020
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • Muhammad Nasir Ullah +4
  • Conference Article
  • Citations1

Depth-of-interaction Reconstruction in NeuroEXPLORER

  • Oct 16, 2021
  • Tao Feng +3
  • Research Article
  • Citations69

Continuous depth-of-interaction measurement in a single-layer pixelated crystal array using a single-ended readout

  • Feb 06, 2013
  • Physics in Medicine and Biology
  • Mikiko Ito +2
  • Conference Article
  • Citations6

DOI Detection Capability of 3D Crystal Array Standing over Two PMTs

  • Jan 01, 2005
  • M Hamamoto +5
  • Research Article

Depth-of-interaction enhanced Compton camera using pixelated LYSO(Ce) scintillator arrays and dual-ended SiPMs.

  • Jun 01, 2026
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
  • Xiaowen Tian +6
  • PDF
  • Research Article
  • Citations18

Development and initial characterization of a high-resolution PET detector module with DOI

  • Oct 14, 2020
  • Biomedical physics & engineering express
  • Mohan Li +2
  • Research Article
  • Citations2

Imaging performance evaluation in depth-of-interaction PET with a new method of sinogram generation:A Monte Carlo simulation study

  • Nov 15, 2013
  • 《核技术》(英文版)
  • Yan Xia +5
  • Research Article
  • Citations13

A layered single-side readout depth of interaction time-of-flight-PET detector

  • Feb 10, 2021
  • Physics in Medicine & Biology
  • L Bläckberg +3
  • Conference Article
  • Citations8

Small Animal PET Camera Design Based on 2-mm Straw Detectors

  • Jan 01, 2006
  • Nader N Shehad +4
  • Research Article
  • Citations155

A detector head design for small-animal PET with silicon photomultipliers (SiPM)

  • Feb 09, 2006
  • Physics in Medicine & Biology
  • Sascha Moehrs +3
  • Conference Article
  • Citations6

Timing resolution improved by DOI information in an LYSO TOF-PET detector

  • Jan 01, 2007
  • Kengo Shibuya +7
  • Research Article
  • Citations54

The Silicon Photomultiplier for application to high-resolution Positron Emission Tomography

  • Nov 27, 2006
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • D.J Herbert +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.