• Home
  • Search
  • Phase Current Reconstruction and Control of Three-Phase Switched Reluctance Machine With Modular Power Converter Using Single DC-Link Current Sensor
  • Cite Icon79
  • https://doi.org/10.1109/tpel.2017.2782562Copy DOI Icon

Phase Current Reconstruction and Control of Three-Phase Switched Reluctance Machine With Modular Power Converter Using Single DC-Link Current Sensor

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

According to the modular power converter, a novel phase current reconstruction method using single dc-link current sensor is proposed for three-phase switched reluctance machine (SRM), and the control method is implemented with the reconstructed phase current as well. A highly integrated modular power converter is constructed by a three-phase full bridge and a dual switch module. The phase windings are in star-connection, and the bipolar phase currents are applied. Based on the special operating modes and single pulse width modulation signal injection, the dc-link current is decoupled and the phase current in both magnetization and demagnetization regions is reconstructed, which is very critical for the implementation of some advanced methods that require complete period phase current. The conventional control methods of the SRM, such as single-pulse voltage and hysteresis current control methods, are carried out under different operating conditions with both simulation and experiment to verify the effectiveness of the proposed method, and the reconstruction errors and performance influences are detailed analyzed as well.

Similar Papers
  • Conference Article
  • Citations3

Sliding mode direct power control of three-phase PWM boost rectifier using a single DC current sensor

  • Nov 01, 2013
  • M Ben Said-Romdhane +3
  • PDF
  • Research Article
  • Citations2

DC-Link Current Control with Inverter Nonlinearity Compensation for Permanent Magnet Synchronous Motor Drives

  • Jan 22, 2020
  • Energies
  • Kan Wang +2
  • Conference Article
  • Citations9

Phase current reconstruction with single DC-link current sensor for six-step operation in three phase inverter

  • Sep 01, 2015
  • Jaeyoung Park +2
  • Conference Article
  • Citations9

Three phase current reconstruction method using predictive current in three shunt sensing PWM inverter

  • Jun 01, 2016
  • Young-Hee Jang +5
  • Conference Article

Technique for Reconstruction of Phase Currents and Detection of Faults of Three-Phase Inverter using One DC Link Current Sensor

  • Oct 23, 2025
  • Germans Popovs +1
  • Research Article
  • Citations16

Asymmetric SVPWM and Error Suppression Method for Current Reconstruction of T-Type Three-Level Inverter

  • May 01, 2024
  • IEEE Transactions on Power Electronics
  • Yongpeng Shen +5
  • Conference Article
  • Citations12

Closed loop control of BLDC motor using a fuzzy logic controller and single current sensor

  • Dec 01, 2013
  • Tony Mathew +1
  • Research Article
  • Citations79

Saliency-Based Position Estimation of Permanent-Magnet Synchronous Machines Using Square-Wave Voltage Injection With a Single Current Sensor

  • Mar 01, 2015
  • IEEE Transactions on Industry Applications
  • Shih-Chin Yang
  • Research Article
  • Citations128

A novel control method for three-phase PWM rectifiers using a single current sensor

  • Sep 01, 2000
  • IEEE Transactions on Power Electronics
  • Woo-Cheol Lee +2
  • Conference Article
  • Citations8

A Speed PMSM Control Technique With a Single DC Bus current Sensor

  • Oct 01, 2019
  • Mokrane Bala +4
  • Research Article
  • Citations1

Modeling, Simulation and a Comparative study between a Single-phase Switched Reluctance Machine (6x6) and a Three-phase Switched Reluctance Machine

  • Jan 17, 2024
  • RE&PQJ
  • Dias, R J +6
  • Research Article
  • Citations3

Phase Current Reconstruction Techniques for Two-Phase Inverters using a Single Current Sensor

  • Nov 20, 2011
  • Journal of Power Electronics
  • Young-Hoon Cho +4
  • Research Article
  • Citations117

Current Prediction in Vector-Controlled PWM Inverters Using Single DC-Link Current Sensor

  • Feb 01, 2010
  • IEEE Transactions on Industrial Electronics
  • Jung-Ik Ha
  • Research Article

Robust Current Observer Design for PMSM Drives Using a Single DC-Link Current Sensor

  • Jan 01, 2025
  • IEEE Journal of Emerging and Selected Topics in Power Electronics
  • Pengcheng Zhu +5
  • Conference Article
  • Citations1

Implementation and Comparison Study of Single-Pulse and PWM control Method to Increase Regenerative Braking Efficiency for SRM

  • Oct 18, 2022
  • Stanislaus Hans Ryandita +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.