- Research Article
19
- 10.1016/j.ifacol.2017.08.168
Advanced Tuning for Ziegler-Nichols Plants
- Jul 01, 2017
- IFAC PapersOnLine
- Iván D Díaz-Rodríguez + 3 more +3
Advanced Tuning for Ziegler-Nichols Plants
This paper proposes a step by step procedure design and analysis of proportional Integral (PI) and proportional integral derivative (PID) controller. These controllers are employed to control the speed of a DC shunt motor. DC shunt motor Characteristics are modeled in s-function, the speed characteristic of motor is analyzed in open loop condition and closed loop condition without controller and Parameter controlling of PI & PID controller is designed by frequency response analysis. Design, analysis and implementation of PI & PID controller are conducted separately. The performances controllers such as rise time (tr), settling time (ts), steady state error, percent overshoot (%OS), and phase margin are compared to both controllers. Design and analysis of controller are verified by simulation, the results show that PID controller that applied speed control DC shunt motor is better than PI controller.
Advanced Tuning for Ziegler-Nichols Plants
Advanced Tuning for Ziegler-Nichols Plants
Comparison of Speed Control of PMSM using Adaptive Fuzzy Logic Controller and PI Controller
Permanent Magnet Synchronous Motors (PMSM) are widely used in low and mid power applications such as computer peripheral equipment, robotics, adjustable speed drives and electric vehicles. The growth in the market of permanent magnet motor drives has demanded the need of simulation tools capable of handling motor drive simulations. Simulations have helped the process of developing new systems including motor drives, by reducing cost and time. In a closed loop system, the speed of a permanent magnet synchronous motor can be controlled by measuring the actual speed of the motor. PI (Proportional Integral), PID (Proportional Integral Derivative) and fuzzy controllers are commonly used for the speed control. In this study, the speed responses of a PMSM are obtained using adaptive fuzzy PID controller. A parallel combination of two controllers, fuzzy PD controller and a fuzzy PI controller, forms the adaptive fuzzy PID controller. Switching action take place between the two controllers based on the error in the speed. MATLAB/Simulink is used for the simulation. A comparison and analysis is made between PI controller and adaptive fuzzy logic controller. Keywords: Permanent Magnet Synchronous Motor (PMSM), PI controller, adaptive fuzzy, speed control Cite this Article Vishnu Mahesh J, Karthika S. Comparison of Speed Control of PMSM using Adaptive Fuzzy Logic Controller and PI Controller. Journal of Power Electronics & Power Systems. 2018; 8(3): 24–30p.
Read moreCompressor speed control design using PID controller in hydrogen compression and transfer system
Compressor speed control design using PID controller in hydrogen compression and transfer system
Comparative Study of PI and PID Controller for Non Linear MIMO System
There are lot of controllers in process control such as on-off, PI, PD and PID controllers. But commonly used controllers in industrial control applications are proportional-integral (PI) and proportional-integral-derivative (PID) controllers. A PI controller is used when fast response of the system is not required. PID controller has the advantage of high stability and reliability. The PID controller is having the accurate and efficient tuning of parameters. Generally, most industrial processes are multivariable systems. It is difficult to tune the gains of PI and PID controllers because many industrial plants are often burdened with problems like high order, time delays, poor damping, nonlinearities, and time-varying dynamics etc. That means, the proper design of multi-loop PID control for multivariable process is a challenging task. In this paper, PI and PID controllers are designed for multi-input multi-output system. To validate the performance of PI and PID control design, binary Wood-Berry distillation column which is a multivariable, non linear process with strong interactions with input and output pairs is taken and compared their performances.
Read morePID Controller Design for Complex Systems
The proportional integral derivative (PID) controller design methods are either model based approaches or rule based approaches. It is clear that when using a model based approach, a first order model yields a PI controller and a second order model yields a PID controller. In some applications, the first order and second order models are basically an approximation to the actual physical systems. This chapter explains how to design PID controllers for higher order systems directly using frequency response data. It presents PID controller design via specification of gain margin and phase margin. The chapter then discusses an intuitive and simple approach to PID controller design from the perspective of curve fitting of the frequency response of the loop transfer function. It presents tutorials to produce a MATLAB program for PID controller design using two frequency response points and to test this program using a simulation example.
Read moreSpecial issue on PID control in the information age: Theoretical advances and applications
Special issue on PID control in the information age: Theoretical advances and applications
Performance Analysis of PI and PID Controllers in Process and Cruise Control Systems
Proportional-Integral (PI) and Proportional-Integral-Derivative (PID) controllers are commonly employed in process and Cruise Control Systems (CCS) to control system behaviour. PID controllers have a derivative action to improve transient response and system stability, while PI controllers use proportional and integral actions to minimise steady-state errors. This study explores the performance of both controllers in these applications by designing and implementing them within each system. The methodology involves simulating the systems under different conditions, including variations in setpoints and disturbances, to observe how the controllers manage dynamic behavior. The study assesses both controllers' performance in various scenarios, emphasising their capacity to manage disruptions and preserve stability. The study's objective is to offer a thorough comprehension of the design and performance characteristics of PI and PID controllers in process and CCS, offering insights into their suitability based on specific system requirements and performance goals. The PI controller is found to be the best choice for certain applications due to its simplicity and effectiveness
Read moreDE optimized IPIDF controller for management frequency in a networked power system with SMES and HVDC link
A major concern is frequency change with load. So, Load Frequency Control (LFC) of an interconnected power system is proposed in this research using a unique integral plus proportional integral derivative controller with filter (IPIDF). The Differential Evolution (DE) algorithm is used to optimize the integral plus proportional integral derivative controller with filter controller parameters for a two-area power system. By contrasting the results of the proposed method with those of recently published optimization techniques for the same power system, such as the Particle Swarm Optimization (PSO), Genetic Algorithm (GA), Firefly Algorithm (FA), and Differential Evolution (DE) based Proportional integral derivative (PID) and PIDF controllers, the superiority of the integral plus proportional integral derivative controller with filter approach is made clear. It is possible to determine the system performance index like integral time multiplied the absolute error (ITAE) and the settling time (Ts). The power system with superconducting magnetic energy storage and an HVDC link is also included in the proposed work, and the values of the suggested integral plus proportional integral derivative controller with filter controllers are evaluated using the Differential Evolution method. By comparing the outcomes with the Differential Evolution tuned PIDF controller for the identical power systems, the suggested controller’s superiority is demonstrated. To show the stability of the recommended Differential Evolution algorithm tuned integral plus proportional integral derivative controller with filter controller, the speed governor, turbine, synchronizing coefficient, and frequency bias parameters’ time constants and operating load conditions are varied in the range of +25 to −25% from their nominal values, along with the magnitude and location of step load perturbation and pulse load perturbation, to perform sensitivity analysis. According to research, proposed integral plus proportional integral derivative controller with filter controllers offer greater dynamic response by minimizing time required to settle and undershoots than Proportional integral derivative controllers and PIDF controllers. MATLAB/Simulink is used to run the simulations.
Read moreChaos Algorithm versus Traditional and Optimal Approaches for Regulating Line Frequency of Steam Power System
Load Frequency Control (LFC) is a basic control strategy for proper operation of the power system. It ensures the ability of each generator in regulating its output power in such way to maintain system frequency and tie-line power of the interconnected system at prescribed levels. This article introduces comprehensive comparative study between Chaos Optimization Algorithm (COA) and optimal control approaches, such as Linear Quadratic Regulator (LQR), and Optimal Pole Shifting (OPS) regarding the tuning of LFC controller. The comparison is extended to the control approaches that result in zero steady-state frequency error such as Proportional Integral (PI) and Proportional Integral Derivative (PID) controllers. Ziegler-Nicholas method is widely adopted for tuning such controllers. The article then compares between PI and PID controllers tuned via Ziegler-Nicholas and COA. The optimal control approaches as LQR and OPS have the characteristic of steady-state error. Moreover, they require the access for full state variables. This limits their applicability. Whereas, Ziegler-Nicholas PI and PID controllers have relatively long settling time and high overshoot. The controllers tuned via COA remedy the defects of optimal and zero steady-state controllers. The performance adequacy of the proposed controllers is assessed for different operating scenarios. Matlab and its dynamic platform, Simulink, are used for stimulating the system under concern and the investigated control techniques. The simulation results revealed that COA results in the smallest settling time and overshoot compared with traditional controllers and zero steady-state error controllers. In the overshoot, COA produces around 80% less than LQR and 98.5% less than OPS, while in the settling time, COA produces around 81% less than LQR and 95% less than OPS. Moreover, COA produces the lowest steady-state frequency error. For Ziegler-Nicholas controllers, COA produces around 53% less in the overshoot and 42% less in the settling time.
Read moreTLBO Optimised PIDD Controller for Coordinated Control in a Hybrid AC/DC Microgrid
Due to the increasing penetration of renewable energy sources (RES), frequency regulation has become more challenging. In electrical power network, the load frequency control (LFC) mechanism is a very crucial function for keeping an equilibrium between the power generation and load to avoid frequency deviation (FD). The paper aims to implement an effective LFC scheme for a hybrid AC/DC microgrid (MG) system comprising of wind turbine generator (WTG) and battery energy storage system (BESS). Proportional integral double derivative (PIDD) controllers are used to implement the LFC scheme. The controller parameters are computed using a teaching-learning-based optimization (TLBO) algorithm. The responses acquired using PIDD controllers are compared with the responses obtained using Proportional integral (PI) and Proportional integral derivative (PID) controllers. A critical analysis reveals that the PIDD controller shows better dynamic responses in terms of settling time and magnitude of oscillations compared to the PI and PID controllers. Furthermore, the robustness of the proposed PIDD based LFC scheme is ascertained under different system loadings.
Read moreThe speed control of DC motor under the load condition using PI and PID controllers
In this study, it was aimed to compare PI (Proportional–Integral) and PID (Proportional–Integral–Derivative) controllers for speed control of Permanent Magnet Direct Current (PMDC) motor under both load and without load. For this purpose, firstly, the mathematical model was obtained from the dynamic equations of the PMDC motor and the obtained mathematical model was transferred to the simulation environment and modeled using Matlab/SIMULINK. Following the modeling process, PI and PID controller structures were formed, respectively. Secondly, after these structures were formed, the PMDC motor was run without any controller. Then, the control of the PMDC motor with no load was provided by using PI and PID controllers. Finally, the PMDC motor were loaded under the constant load (TL = 3 N.m.) for each condition and selected time period (t = 3 s). The obtained result for each control operations was comparatively given by observing effects of loading process on systems. When the obtained results were evaluated for each condition, it was observed that PID controller have the best performance with respect to PI controller.
Read moreAutomatic Load Frequency Control of Three Area Power System Using Artificial Intelligence
This papers offers using of artificial intelligence (AI) technique to control the parameters of a three area power system having a three non-reheating thermal power units. The dynamic output of power system has been analyzed for step load disturbance. Proportional integral (PI) and proportional integral derivative (PID) controllers are used to control the various parameters of multi area power system. Due to high peak overshoot and settling time, conventional PI and PID controllers are not preferred for large power system. The main motivation of this paper is to control the output frequency response with minimum peak overshoot and settling time. The output frequency response with fuzzy logic based controller indicates that fuzzy tuned proportional integral derivative (FTPID) controller is very much better than Ziegler-Nichols tuned PI and PID controllers.
Read moreTemperature control of beer fermentation based on variable domain fuzzy PID and neural network technology and its application analysis
Temperature control in the beer manufacturing process is crucial for product quality. Given the gap between China's automation in beer production and the international level, improving the technology in this area has gradually become a core issue in optimizing domestic beer production. This study combines a proportional integral derivative controller with a fuzzy modeling strategy and incorporates a variable‐domain structure to propose a variable‐domain fuzzy proportional integral derivative controller control method. To cope with the challenges of production interaction, the study also introduces neural network technology. The experimental data indicated that the variable‐domain fuzzy proportional integral derivative controller outperforms the conventional proportional integral derivative controller and the fuzzy proportional integral differential controller in terms of overshooting, with a maximum overshoot of only 1.0, compared with 0.50 and 0.70, respectively. The variable‐domain fuzzy proportional integral differential controller exhibited a minimal overshoot of only 0.01 when the model parameter is increased by 20%. In comparison, the other methods reach overshoot values of 0.92 and 1.0. The proposed method maintained superior stability even under the influence of impulse disturbance, step disturbance, and modeling variations. These results demonstrated that the research method is significantly more stable than both the proportion integration differentiation (PID) controller and fuzzy PID controller in complex dynamic parameter environments. The proposed method involved 60 rounds of neural network control, which was successfully implemented. The temperature readings T1 and T2 remained stable within the range of 1.0%–1.02% throughout the experiments. The study demonstrates that the proposed methods have higher accuracy and less fluctuation in actual application, making them more available. Taken together, the above results show that the combination of variable‐domain fuzzy PID controller and neural network technology in beer production has achieved excellent control results. This study not only provides a strong technical support for the progress of beer production technology in China, but also has important industrial application value and wide promotion prospects.
Read moreEffect of Variable Damping Ratio on design of PID Controller
This paper presents the effect of Variable Damping Ratio on design of Proportional Integral Derivative (PID) Controller. This novel method is very useful because of their successful practical application, robustness and simplicity. The most popular and widely used controllers in industries are PID controllers. To find appropriate parameters, many design methods have been proposed for PID controller with having its own merits and demerits. However, it is still not easy to find appropriate parameters for the PID controllers. In this paper, PID having variable Damping ratio is developed to improve the performance of the controller. By using this method there is a 60% saving in settling time as compared to the method proposed by Ziegler Nicholas and 84.6% saving settling time as compared to technique proposed by Salem. Our method is independent of maximum overshoot which is distinguishable advantage which increases the performance of system. Based on the mathematical model of the system, controller is designed and is estimated by the MATLAB version 2013. Data for model estimation is taken from an experimental works, the performance has improved significantly of the PID controller having variable damping ratio compare to conventional PID controller.
Read moreFPGA-based PID controller for DC-DC converter
Proportional Integral Derivative (PID) controller is the most preferable controller in industries that does not require precise analytical model of the system to be controlled. This paper presents a design and implementation of PID (Proportional-Integral-Derivative) controller based on FPGA (Field-Programmable Gate Arrays) for low voltage synchronous buck Converter. Matlab/Simulink environment is used for the PID controller design to generate a set of coefficients associated with the desired controller characteristics. These controller coefficients are then included in VHDL that implements the PID controller on to FPGA. The two architectures of PID controller are considered with their device utilization and power dissipation reports to show the resource utilization and power dissipation of selected FPGA. The architectures are implemented in FPGA Virtex-5(ML505) XC5VLX50T-1FF1136 (-1 speed grade) device.
Read more