Abstract

To evaluate prospective motion correction using the pilot tone (PT) as a quantitative respiratory motion signal with high temporal resolution for cardiac cine images during free breathing. Before cine data acquisition, a short prescan was performed, calibrating the PT to the respiratory-induced heart motion using respiratory-resolved real-time images. The calibrated PT was then applied for nearly real-time prospective motion correction of cine MRI through slice tracking (ie, updating the slice position before every readout). Additionally, in-plane motion correction was performed retrospectively also based on the calibrated PT data. The proposed method was evaluated in a moving phantom and 10 healthy volunteers. The PT showed very good correlation to the phantom motion. In volunteer studies using a long-term scan over 7.96 ± 1.40 min, the mean absolute error between registered and predicted motion from the PT was 1.44 ± 0.46 mm in head-feet and 0.46 ± 0.07 mm in anterior-posterior direction. Irregular breathing could also be corrected well with the PT. The PT motion correction leads to a significant improvement of contrast-to-noise ratio by 68% (P ≤ .01) between blood pool and myocardium and sharpness of endocardium by 24% (P = .04) in comparison to uncorrected data. The image score, which refers to the cine image quality, has improved with the utilization of the proposed PT motion correction. The proposed approach provides respiratory motion-corrected cine images of the heart with improved image quality and a high scan efficiency using the PT. The PT is independent of the MR acquisition, making this a very flexible motion-correction approach.

Similar Papers
  • Research Article
  • Citations23

Prospective motion correction in functional MRI using simultaneous multislice imaging and multislice-to-volume image registration

  • Jun 19, 2019
  • NeuroImage
  • Daniel Christopher Hoinkiss +5
  • Research Article
  • Citations19

Patient specific prospective respiratory motion correction for efficient, free-breathing cardiovascular MRI.

  • Feb 14, 2019
  • Magnetic Resonance in Medicine
  • Michael A Bush +4
  • Research Article
  • Citations104

An embedded optical tracking system for motion-corrected magnetic resonance imaging at 7T

  • Jun 13, 2012
  • Magnetic Resonance Materials in Physics, Biology and Medicine
  • Jessica Schulz +7
  • Research Article
  • Citations19

Free-breathing cardiac cine MRI with compressed sensing real-time imaging and retrospective motion correction: clinical feasibility and validation.

  • Nov 10, 2022
  • European Radiology
  • Lu Lin +8
  • Research Article
  • Citations3

Motion detection and correction for carotid MRI using a markerless optical system

  • Sep 30, 2022
  • Magnetic Resonance Imaging
  • Jin Liu +9
  • PDF
  • Research Article
  • Citations98

High spatial and temporal resolution retrospective cine cardiovascular magnetic resonance from shortened free breathing real-time acquisitions.

  • Jan 01, 2013
  • Journal of Cardiovascular Magnetic Resonance
  • Hui Xue +4
  • Research Article
  • Citations61

Respiratory Motion Detection and Correction for MR Using the Pilot Tone

  • Dec 31, 2019
  • Investigative Radiology
  • Thomas Vahle +8
  • Research Article
  • Citations3

Prospective motion correction for brain MRI using spherical navigators.

  • Jan 04, 2024
  • Magnetic Resonance in Medicine
  • Miriam Hewlett +3
  • Research Article

Real-time multislice-to-volume motion correction for task-based EPI-fMRI at 7T.

  • Jan 01, 2026
  • Magnetic resonance imaging
  • Steven Winata +4
  • Research Article

TH-E-110-08: Free Breathing Hepatic CT Perfusion with Automatic a Posteriori Motion Correction

  • Jun 01, 2011
  • Medical Physics
  • N Jensen +7
  • Research Article
  • Citations1

B0-insensitive image navigators for prospective motion-corrected MRS with localized second-order shimming.

  • May 05, 2024
  • Magnetic resonance in medicine
  • Isaac M Adanyeguh +3
  • Research Article
  • Citations12

T1 -FLAIR imaging during continuous head motion: Combining PROPELLER with an intelligent marker.

  • Sep 01, 2020
  • Magnetic Resonance in Medicine
  • Ola Norbeck +6
  • Research Article

Brain MRI Dataset Featuring a Full Clinical Protocol With and Without Intentional Motion.

  • Apr 23, 2026
  • Scientific data
  • Kathrine Skak Madsen +4
  • Research Article

Optimization of motion-corrected liver diffusion-weighted imaging at 3 Tesla (3T): incorporating complex averaging and reparametrized sinc fatsat pulse with optimized water excitation pulse.

  • Sep 01, 2024
  • Quantitative imaging in medicine and surgery
  • Zhiyong Chen +8
  • Research Article

Motion and temporal B0-shift corrections for QSM and mapping using dual-echo spiral navigators and conjugate-phase reconstruction.

  • Sep 04, 2024
  • Magnetic resonance in medicine
  • Yuguang Meng +3