• Home
  • Search
  • Power Flow Analysis for the Steel Industry
  • Cite Icon1
  • https://doi.org/10.36548/jei.2025.2.006Copy DOI Icon

Power Flow Analysis for the Steel Industry

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Significant equipment like electric arc furnaces (EAFs) and ladle refining furnaces (LRFs) are among the highly dynamic and nonlinear electrical loads found in steel production facilities like Surana Industry. Reactive power imbalance, harmonic distortion, and voltage instability are just a few of the significant power quality issues caused by these complex loads. Because of this, accurate modeling and thorough analysis of these complex power systems are essential to ensuring operational dependability and maintaining power quality. The current literature tends to emphasize mostly steady-state conditions that are frequently not verified empirically with respect to actual operating data, despite the fact that the Electrical Transient Analyzer Program (ETAP) is a common tool used for load flow analysis in industry applications. With an emphasis on accurately simulating the real system behavior under various operating regimes, this paper provides a thorough power flow analysis of the Surana Steel Industry using ETAP. Two 100 MVA, 220/110 kV transformers step down the 110 kV supply that powers the plant, which is drawn from the Chikkasagur substation. The primary loads—a 35-ton rolling mill, a 4 MW EAF, and an LRF are supplemented with a captive power generation system and a harmonic filter to improve power quality and reliability. Under five different operating conditions with different load levels and generator configurations, key performance metrics such as voltage regulation, reactive power flow, harmonic suppression, and generator dynamic response are thoroughly assessed. The power system of the Surana Steel Industry is accurately simulated by the analytical method employed here. Even though a real-time comparison with SCADA data was not attempted, the ETAP model was painstakingly built with detailed equipment specs, typical operating conditions, and performance patterns actually observed at the facility. Accurate simulation of industrial environments, including the complex, unbalanced, and nonlinear loads present in steel mills, was made possible by this all-encompassing approach. Thus, this study shows that when appropriately configured and backed by extensive empirical data, ETAP has a considerable ability to accurately model these difficult environments. These results offer practical information that can be used right away for large-scale industrial power system planning, assessment, and enhancement.

Similar Papers
  • Conference Article
  • Citations28

Analyses and monitoring of 132 kV grid using ETAP software

  • Dec 18, 2009
  • Rana Abdul Jabbar Khan +2
  • Research Article

The effect of distributed generator injection in different number of units on power and voltage losses in the electricity distribution system

  • Nov 13, 2024
  • Journal Geuthee of Engineering and Energy (JOGE)
  • Mahdi Syukri +1
  • Research Article

Power Quality Assessment for a Fluctuating Load Based on the Electrical Transient Analysis Program

  • Jul 01, 2018
  • IOP Conference Series: Materials Science and Engineering
  • Pengfei Shen +3
  • Conference Article

Modeling and Analysis of 300 MW Photovoltaic System Using ETAP and Harmonic Filter Design

  • Jan 18, 2023
  • Mehrauz Rehmat +2
  • Conference Article
  • Citations1

Applied modelling and analysis to investigate the potential of a 11kV networked site to accommodate EV charging infrastructure

  • Sep 01, 2015
  • Yaminidhar Reddy Bhavanam +4
  • PDF
  • Research Article
  • Citations14

The Central American Power System: Achievements, Challenges, and Opportunities for a Green Transition

  • May 25, 2023
  • Energies
  • Gustavo Adolfo Gómez-Ramírez +4
  • Book Chapter
  • Citations23

Power Quality and Electrical Arc Furnaces

  • Apr 11, 2011
  • Horia Andrei +2
  • Research Article
  • Citations10

A numerical study of rotating annulus flows using a modified Galerkin method

  • Aug 01, 1973
  • Pure and Applied Geophysics
  • David E Dietrich
  • Conference Article

Using Multi-Mode PV-STATCOM System for Steel Plant Power System Voltage Fluctuation Mitigation

  • Nov 01, 2020
  • Yu-Jen Liu +4
  • Research Article
  • Citations6

Comparison of DC Electric Arc Furnace Chaotic Models for Power Quality Indices Assessment

  • Nov 01, 2021
  • IEEE Transactions on Industry Applications
  • Antonio Bracale +4
  • Research Article
  • Citations2

Harmonic Reduction of Arc Furnaces Using D-Statcom

  • Apr 01, 2013
  • IOSR Journal of Engineering
  • S Pushpavalli
  • PDF
  • Research Article
  • Citations3

Разработка усовершенствованной методики расчета параметров фильтрокомпенсирующих цепей статического тиристорного компенсатора электродуговой печи

  • Jan 01, 2018
  • Bulletin of the South Ural State University series "Power Engineering"
  • А.Л Николаев +5
  • Research Article
  • Citations8

Performance analysis of hybrid metaheuristic assisted collateral FO controller for HRES system integrated UPQC

  • Sep 25, 2024
  • Computers and Electrical Engineering
  • Shravan Kumar Yadav +1
  • Research Article

Deep-Learning-Based Controller for Parallel DSTATCOM to Improve Power Quality in Distribution System

  • Sep 15, 2025
  • Energies
  • A Kasim Vali +4
  • Research Article
  • Citations21

A novel method of electrical arc furnace modelling for flicker study

  • Mar 01, 2007
  • Renewable Energy and Power Quality Journal
  • M.A Golkar +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.