Precise measurement of power system frequency and phasor using SDFT and comparison with DFT based approach

  • Sep 1, 2017
  • Virajkumar I Suryawanshi +1 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Power system condition is reflected by frequency and phasor more accurately. State of power system is shown by phasor while real time balance between generation and load is reflected by frequency. Frequency undergoes variation from the standard value when there is a difference between generation of electrical power and load. Some power system protection and control applications, e.g., frequency relay for load shedding, load-frequency controller requires precise and fast estimation of the frequency. So frequency and phasor regarded as indices for the operating power system in practice. To gain efficient and safe operation of power system caused due to any significant variation from nominal frequency forces protective devices to take corrective actions. As phasor is important parameter in the frequency monitoring and control of power systems and it is not constant at off-nominal frequencies, its measurement at every instant in power system network with greater accuracy and fast speed is necessary. Discrete Fourier Transforms (DFT) is one of the most important tools in Digital Signal Processing (DSP). It can calculate signal's frequency spectrum, it can find system's frequency response and it allows systems to be analyzed in the frequency domain. Conventional DFT method produces errors in calculating phasor and frequency if frequency varies from standard value. Smart Discrete Fourier Transforms (SDFT) has all merits of DFT such as recursive computation, ease of implementation and real time suitability. SDFT also takes care of deviations in frequency, harmonics and noise. This paper presents a SDFT based algorithm for measuring frequency, amplitude and phase angle of an ac signal and its comparison with conventional DFT method. Different signals in the presence of noise and harmonics are tested with the presented algorithm.

Similar Papers
  • Conference Article
  • Citations11

A smart method makes DFT more precise for power system frequency estimation

  • Jan 01, 1999
  • IEEE Power Engineering Society. 1999 Winter Meeting (Cat. No.99CH36233)
  • Jun-Zhe Yang +1
  • Research Article
  • Citations132

A Precise Calculation of Power System Frequency

  • Apr 01, 2001
  • IEEE Power Engineering Review
  • J Z Yang +1
  • Conference Article
  • Citations2

Precise calculation of power system frequency and phasor using SDFT

  • Jul 01, 2017
  • Aditya A Lokhande
  • Research Article
  • Citations188

A precise calculation of power system frequency and phasor

  • Apr 01, 2000
  • IEEE Transactions on Power Delivery
  • Jun-Zhe Yang +1
  • Conference Article

On enhancing power systems PMU based data analysis and condition monitoring

  • Oct 01, 2015
  • P Mohammadi +1
  • PDF
  • Research Article

Performance of Implementing Smart DFT in Micro Phasor Measurement Unit

  • Jan 01, 2018
  • E3S Web of Conferences
  • Chao-Yuan Lai +2
  • Conference Article
  • Citations46

Complete elimination of DC offset in current signals for relaying applications

  • Nov 07, 2002
  • Jun-Zhe Yang +1
  • Research Article
  • Citations80

A Complex Least Squares Enhanced Smart DFT Technique for Power System Frequency Estimation

  • Jun 01, 2017
  • IEEE Transactions on Power Delivery
  • Yili Xia +5
  • Research Article

A new method of deconvolution in the frequency domain

  • Apr 01, 1997
  • Journal of Electronics (China)
  • Wang Yanfei
  • Conference Article
  • Citations13

A new family of measurement technique for tracking voltage phasor, local system frequency, harmonics and DC offset

  • Nov 07, 2002
  • Jun-Zhe Yang +1
  • Book Chapter

PMU Phasor Estimation Using Different Techniques

  • Nov 03, 2020
  • Hamid Bentarzi +1
  • Conference Article
  • Citations8

Removing decaying DC component in fault currents via a new modify discrete fourier algorithm

  • Jun 12, 2005
  • IEEE Power Engineering Society General Meeting, 2005
  • Chi-Shan Yu +1
  • Conference Article
  • Citations4

A least squares enhanced smart DFT technique for frequency estimation of unbalanced three-phase power systems

  • Jul 01, 2016
  • Yili Xia +4
  • Research Article

Application of automation technology in power system protection and control

  • Jan 01, 2025
  • Applied Mathematics and Nonlinear Sciences
  • Lirong Xiao +2
  • Conference Article
  • Citations5

An effective filtering algorithm to mitigate transient decaying DC offset

  • Apr 01, 2014
  • Abouzar Rahmati +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.