• Home
  • Search
  • Probe versus microscope: a comparison of different methods for image-to-patient registration
  • Cite Icon7
  • https://doi.org/10.1007/s11548-018-1800-0Copy DOI Icon

Probe versus microscope: a comparison of different methods for image-to-patient registration

Show More
  • Abstract
  • Highlights & Summary
  • PDF
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

PurposeComputer-aided navigation is widely used in ENT surgery. The position of a surgical instrument is shown in the CT/MR images of the patient and can thus be a good support for the surgeon. The accuracy is highly dependent on the registration done prior to surgery. A microscope and a probe can both be used for registration and navigation, depending on the surgical intervention. A navigation system typically only reports the fiducial registration error after paired-point registration. However, the target registration error (TRE)—a measurement for the accuracy in the surgical area—is much more relevant. The aim of this work was to compare the performance of a microscope relative to a conventional probe-based approach with different registration methods.MethodsIn this study, optical tracking was used to register a plastic skull to its preoperative CT images with paired-point registration. Anatomical landmarks and skin-affixed markers were used as fiducials and targets. With both microscope and probe, four different registration methods were evaluated based on their TREs at 10 targets. For half of the experiments, a surface registration and/or external fiducials were used additionally to paired-point registration to study their influence to accuracy.ResultsOverall, probe registration leads to a smaller TRE (1.69 pm 0.74,hbox {mm}) than registration with a microscope (2.19 pm 0.94,hbox {mm}). Additional surface registration does not result in better accuracy of navigation for microscope and probe. The lowest mean TRE for both pointers can be achieved with paired-point registration only and radiolucent markers.ConclusionOur experiments showed that a probe used for registration and navigation achieves lower TREs compared using a microscope. Neither additional surface registration nor additional fiducials on an external reference element are necessary for improved accuracy of navigated ENT surgery on a plastic skull.

Loading PDF

Similar Papers
  • Research Article
  • Citations1

S203 – The STAMP Registration for Image‐guided Otologic Surgery

  • Aug 01, 2008
  • Otolaryngology–Head and Neck Surgery
  • Nozomu Matsumoto +3
  • Conference Article

Dynamic coordinate registration method for image-guided surgery

  • Sep 20, 2014
  • Xi Wen +2
  • Research Article

TH‐C‐304A‐06: Assessment of Registration Accuracy in 3D Transrectal Ultrasound Images of Prostates

  • Jun 01, 2009
  • Medical Physics
  • V Karnik +7
  • Research Article
  • Citations18

Real-Time Estimation of FLE Statistics for 3-D Tracking With Point-Based Registration

  • Mar 24, 2009
  • IEEE Transactions on Medical Imaging
  • A.D Wiles +1
  • Conference Article
  • Citations6

Evaluation of motion compensation approaches for soft tissue navigation

  • Mar 06, 2008
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Jochen Krücker +6
  • Research Article
  • Citations22

Rigid-body point-based registration: The distribution of the target registration error when the fiducial registration errors are given

  • Jan 11, 2011
  • Medical Image Analysis
  • A Seginer
  • PDF
  • Research Article
  • Citations14

Calibrating 3D Scanner in the Coordinate System of Optical Tracker for Image-To-Patient Registration

  • May 14, 2021
  • Frontiers in Neurorobotics
  • Wenjie Li +7
  • Research Article
  • Citations5

Real-time intraoperative ultrasound registration for accurate surgical navigation in patients with pelvic malignancies.

  • Dec 04, 2024
  • International journal of computer assisted radiology and surgery
  • M A J Hiep +8
  • PDF
  • Research Article
  • Citations2

Are fiducial registration error and target registration error correlated? SciKit-SurgeryFRED for teaching and research.

  • Feb 15, 2021
  • Proceedings of SPIE--the International Society for Optical Engineering
  • Stephen A Thompson +4
  • Research Article
  • Citations65

Comparison of optical and electromagnetic tracking for navigated lateral skull base surgery

  • May 10, 2013
  • The International Journal of Medical Robotics and Computer Assisted Surgery
  • Florian Kral +3
  • Research Article
  • Citations26

A method for quantitative analysis of regional lung ventilation using deformable image registration of CT and hybrid hyperpolarized gas/1H MRI

  • Nov 10, 2014
  • Physics in Medicine & Biology
  • Bilal A Tahir +10
  • Research Article
  • Citations2

Soft-tissue sound-speed-aware ultrasound-CT registration method for computer-assisted orthopedic surgery.

  • Jun 07, 2024
  • Medical & biological engineering & computing
  • Chuanba Liu +3
  • Research Article
  • Citations2

Accuracy assessment of a novel optical image guided system for trans-nasal sinus and skull base surgeries

  • Aug 15, 2020
  • International Bulletin of Otorhinolaryngology
  • Yerasimos Kyriakides
  • Research Article
  • Citations1

Accuracy and reproducibility of a single-pose image-to-robot registration method for mobile C-arm cone beam CT guided histotripsy.

  • May 31, 2025
  • Journal of applied clinical medical physics
  • Grace M Minesinger +5
  • Conference Article
  • Citations22

Effect of fiducial configuration on target registration error in intraoperative cone-beam CT guidance of head and neck surgery

  • Aug 01, 2008
  • Nathaniel M Hamming +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.