Abstract

Behavioral measures of spatial selectivity in cochlear implants are important both for guiding the programing of individual users’ implants and for the evaluation of different stimulation methods. However, the methods used are subject to a number of confounding factors that can contaminate estimates of spatial selectivity. These factors include off-site listening, charge interactions between masker and probe pulses in interleaved masking paradigms, and confusion effects in forward masking. We review the effects of these confounds and discuss methods for minimizing them. We describe one such method in which the level of a 125-pps masker is adjusted so as to mask a 125-pps probe, and where the masker and probe pulses are temporally interleaved. Five experiments describe the method and evaluate the potential roles of the different potential confounding factors. No evidence was obtained for off-site listening of the type observed in acoustic hearing. The choice of the masking paradigm was shown to alter the measured spatial selectivity. For short gaps between masker and probe pulses, both facilitation and refractory mechanisms had an effect on masking; this finding should inform the choice of stimulation rate in interleaved masking experiments. No evidence for confusion effects in forward masking was revealed. It is concluded that the proposed method avoids many potential confounds but that the choice of method should depend on the research question under investigation.

Similar Papers
  • Research Article

Breaking News

  • Nov 01, 2012
  • The Hearing Journal
  • Alexis T Roy +1
  • Dissertation

Speech masking release in hybrid cochlear implant users

  • Dec 01, 2018
  • Viral Dinesh Tejani +7
  • Research Article

Factors affecting binaural fusion in cochlear implant users.

  • Apr 01, 2026
  • Hearing research
  • Xinyue Zou +9
  • Research Article
  • Citations23

Music Is More Enjoyable With Two Ears, Even If One of Them Receives a Degraded Signal Provided By a Cochlear Implant.

  • Jan 01, 2020
  • Ear & Hearing
  • David M Landsberger +6
  • Research Article

Using vocoders to the implanted ear to investigate the binaural benefit for music sound quality in single-sided deaf cochlear implant users.

  • Mar 01, 2026
  • Hearing research
  • Sean Lang +4
  • Research Article
  • Citations6

Voice Parameters in Children With Cochlear Implants: A Systematic Review and Meta-Analysis

  • Mar 02, 2023
  • Journal of voice : official journal of the Voice Foundation
  • Andrea Frosolini +8
  • Research Article
  • Citations98

On the relationship between auditory cognition and speech intelligibility in cochlear implant users: An ERP study

  • May 19, 2016
  • Neuropsychologia
  • Mareike Finke +4
  • Research Article
  • Citations51

Relationships Among Peripheral and Central Electrophysiological Measures of Spatial and Spectral Selectivity and Speech Perception in Cochlear Implant Users.

  • Feb 05, 2014
  • Ear & Hearing
  • Rachel A Scheperle +1
  • Research Article
  • Citations64

Using Neural Response Telemetry to Monitor Physiological Responses to Acoustic Stimulation in Hybrid Cochlear Implant Users.

  • Jul 01, 2017
  • Ear and hearing
  • Paul J Abbas +3
  • Research Article
  • Citations8

Electrically evoked auditory cortical responses elicited from individually fitted stimulation parameters in cochlear implant users

  • Apr 27, 2022
  • International Journal of Audiology
  • María A Callejón-Leblic +4
  • Research Article
  • Citations3

The effect of delayed auditory feedback (DAF) and frequency altered feedback (FAF) on speech production: cochlear implanted versus normal hearing individuals

  • Jan 31, 2019
  • Clinical Linguistics & Phonetics
  • Riki Taitelbaum-Swead +3
  • PDF
  • Research Article
  • Citations14

Combined Brain-Perfusion SPECT and EEG Measurements Suggest Distinct Strategies for Speech Comprehension in CI Users With Higher and Lower Performance.

  • Aug 11, 2020
  • Frontiers in Neuroscience
  • Mariella Kessler +9
  • Research Article
  • Citations58

Musical and vocal emotion perception for cochlear implants users

  • Aug 25, 2018
  • Hearing Research
  • S Paquette +5
  • Research Article
  • Citations3

Cochlear Implantation in Deaf Children

  • Sep 01, 1997
  • Annals of Saudi Medicine
  • Mohammad J.A Makhdoum +2
  • Research Article
  • Citations60

Fundamental frequency is critical to speech perception in noise in combined acoustic and electric hearing

  • Oct 01, 2011
  • The Journal of the Acoustical Society of America
  • Jeff Carroll +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.