- Research Article
- 10.1097/01.hj.0000422315.94535.3e
Breaking News
- Nov 01, 2012
- The Hearing Journal
- Alexis T Roy + 1 more +1
Breaking News
Behavioral measures of spatial selectivity in cochlear implants are important both for guiding the programing of individual users’ implants and for the evaluation of different stimulation methods. However, the methods used are subject to a number of confounding factors that can contaminate estimates of spatial selectivity. These factors include off-site listening, charge interactions between masker and probe pulses in interleaved masking paradigms, and confusion effects in forward masking. We review the effects of these confounds and discuss methods for minimizing them. We describe one such method in which the level of a 125-pps masker is adjusted so as to mask a 125-pps probe, and where the masker and probe pulses are temporally interleaved. Five experiments describe the method and evaluate the potential roles of the different potential confounding factors. No evidence was obtained for off-site listening of the type observed in acoustic hearing. The choice of the masking paradigm was shown to alter the measured spatial selectivity. For short gaps between masker and probe pulses, both facilitation and refractory mechanisms had an effect on masking; this finding should inform the choice of stimulation rate in interleaved masking experiments. No evidence for confusion effects in forward masking was revealed. It is concluded that the proposed method avoids many potential confounds but that the choice of method should depend on the research question under investigation.
Breaking News
Breaking News
Speech masking release in hybrid cochlear implant users
<p>Improved cochlear implant (CI) designs and surgical techniques have allowed CI patients to retain acoustic hearing in the implanted ear post-operatively. These EAS (electric-acoustic stimulation) CI users listen with a combination of acoustic and electric hearing in the same ear. While electric hearing alone improves speech recognition in quiet, preserved acoustic hearing allows EAS CI users to outperform traditional CI users in speech recognition in noise and demonstrate “speech masking release,” an improvement in speech recognition in temporally fluctuating noise relative to steady noise. Masking release is arguably an ecologically valid metric, as listeners often attend to target speech embedded in fluctuating competing speech. Improved speech recognition outcomes have been attributed to the spectral and temporal resolution provided by acoustic hearing. However, the relationship between spectral and temporal resolution and outcomes in EAS CI users is not clear.</p> <p>This study evaluated speech masking release, spectral ripple density discrimination thresholds, and fundamental frequency difference limens (f0DLs) in EAS CI users. Both the ripple and f0DL tasks are thought to measure underlying spectral resolution and temporal fine structure. EAS CI subjects underwent testing in three listening modes: acoustic-only, electric-only, and acoustic+electric. Comparisons across listening modes allowed the benefit provided by acoustic hearing to be quantified.</p> <p>It was hypothesized that speech masking release, spectral ripple density discrimination thresholds, and f0DLs would be poorest with electric-only hearing and would improve in the acoustic-only and acoustic+electric listening modes. This would reflect the benefit of preserved acoustic hearing. It was also hypothesized that speech masking release would correlate with spectral ripple density discrimination thresholds and f0DLs, reflecting the roles of spectral and temporal fine structure cues. Lastly, it was hypothesized that EAS CI users with more residual hearing (lower audiometric thresholds) would perform better on all three tasks.</p> <p>Speech masking release was evaluated using a 12-alternative-forced-choice (AFC) spondee recognition in noise task. The noise was a two-talker and a ten-talker babble presented at -5 dB SNR, and masking release was quantified as the difference in spondee recognition in two-talker babble relative to ten-talker babble. Spectral ripple density discrimination thresholds were assessed in a 3-AFC task using a broadband stimulus that contained spectral peaks and valleys logarithmically spaced on the frequency axis. The spacing between spectral peaks (ripple density) was varied to determine the threshold at which listeners could no longer resolve the individual spectral peaks. F0DLs were assessed via a 3-AFC task using a broadband harmonic complex with a baseline f0 = 110 Hz. The f0 of the test intervals was varied to determine the smallest change in f0 that the listener could detect.</p> <p>Results showed that performance in all three measures was poorest when EAS CI users were tested using electric-hearing only, with significant improvements when tested in the acoustic-only and acoustic+electric listening modes. F0DLs, but not spectral ripple density discrimination thresholds or audiometric thresholds, significantly correlated with speech masking release. Speech masking release also significantly correlated with open-set AzBio sentence recognition in noise scores obtained from clinical records.</p> <p>Results indicated that preservation of residual acoustic hearing allows for speech masking release, likely due to access to temporal fine structure cues provided by residual hearing. The significant correlation between speech masking release and sentence recognition in noise indicates that the ability to extract target speech embedded in temporally fluctuating competing speech is important for speech recognition in noise.</p> <p>Funded by National Institutes of Health/National Institutes on Deafness and Other Communication Disorders (NIH/NIDCD) P50 DC000242, American Speech-Language-Hearing Foundation Student Research Grant, and American Academy of Audiology Student Investigator Research Grant.</p>
Read moreFactors affecting binaural fusion in cochlear implant users.
Factors affecting binaural fusion in cochlear implant users.
Music Is More Enjoyable With Two Ears, Even If One of Them Receives a Degraded Signal Provided By a Cochlear Implant.
Cochlear implants (CIs) restore speech perception in quiet but they also eliminate or distort many acoustic cues that are important for music enjoyment. Unfortunately, quantifying music enjoyment by CI users has been difficult because comparisons must rely on their recollection of music before they lost their hearing. Here, we aimed to assess music enjoyment in CI users using a readily interpretable reference based on acoustic hearing. The comparison was done by testing "single-sided deafness" (SSD) patients who have normal hearing (NH) in one ear and a CI in the other ear. The study also aimed to assess binaural musical enjoyment, with the reference being the experience of hearing with a single NH ear. Three experiments assessed the effect of adding different kinds of input to the second ear: electrical, vocoded, or unmodified. In experiment 1, music enjoyment in SSD-CI users was investigated using a modified version of the MUSHRA (MUltiple Stimuli with Hidden Reference and Anchor) method. Listeners rated their enjoyment of song segments on a scale of 0 to 200, where 100 represented the enjoyment obtained from a song segment presented to the NH ear, 0 represented a highly degraded version of the same song segment presented to the same ear, and 200 represented enjoyment subjectively rated as twice as good as the 100 reference. Stimuli consisted of acoustic only, electric only, acoustic and electric, as well as other conditions with low pass filtered acoustic stimuli. Acoustic stimulation was provided by headphone to the NH ear and electric stimulation was provided by direct audio input to the subject's speech processor. In experiment 2, the task was repeated using NH listeners who received vocoded stimuli instead of electric stimuli. Experiment 3 tested the effect of adding the same unmodified song segment to the second ear, also in NH listeners. Music presented through the CI only was very unpleasant, with an average rating of 20. Surprisingly, the combination of the unpleasant CI signal in one ear with acoustic stimulation in the other ear was rated more enjoyable (mean = 123) than acoustic processing alone. Presentation of the same monaural musical signal to both ears in NH listeners resulted with even greater enhancement of the experience compared with presentation to a single ear (mean = 159). Repeating the experiment using a vocoder to one ear of NH listeners resulted in interference rather than enhancement. Music enjoyment from electric stimulation is extremely poor relative to a readily interpretable NH baseline for CI-SSD listeners. However, the combination of this unenjoyable signal presented through a CI and an unmodified acoustic signal presented to a NH (or near-NH) contralateral ear results in enhanced music enjoyment with respect to the acoustic signal alone. Remarkably, this two-ear enhancement experienced by CI-SSD listeners represents a substantial fraction of the two-ear enhancement seen in NH listeners. This unexpected benefit of electroacoustic auditory stimulation will have to be considered in theoretical accounts of music enjoyment and may facilitate the quest to enhance music enjoyment in CI users.
Read moreUsing vocoders to the implanted ear to investigate the binaural benefit for music sound quality in single-sided deaf cochlear implant users.
Using vocoders to the implanted ear to investigate the binaural benefit for music sound quality in single-sided deaf cochlear implant users.
Read moreVoice Parameters in Children With Cochlear Implants: A Systematic Review and Meta-Analysis
An intact auditory system is essential for the development and maintenance of voice quality and speech prosody. On the contrary hearing loss affects the adjustments and appropriate use of organs involved in speech and voice production. Spectro-acoustic voice parameters have been evaluated in Cochlear Implant (CI) users, and the authors of previous systematic reviews on the topic concluded that fundamental frequency (F0) seemed preliminarily the most reliable parameter to evaluate voice alterations in adult CI users. The main aim of this systematic review and meta-analysis was to clarify the vocal parameters and prosodic alterations of speech in pediatric CI users. The protocol of the systematic review was registered on the PROSPERO database, International prospective register of systematic reviews. We conducted a search of the English literature published in the period between January 1, 2005 and April 1, 2022 on the Pubmed and Scopus databases. A meta-analysis was conducted to compare the values of voice acoustic parameters in CI users and non-hearing-impaired controls. The analysis was conducted using the standardized mean difference as the outcome measure. A random-effects model was fitted to the data. A total of 1334 articles were initially evaluated using title and abstract screening. After applying inclusion/exclusion criteria, 20 articles were considered suitable for this review. The age of the cases ranged between 25 and 132 months at examination. The most studied parameters were F0, Jitter, Shimmer and Harmonics-to-Noise Ratio (HNR); other parameters were seldom reported. A total of 11 studies were included in the meta-analysis of F0, with the majority of estimates being positive (75%); the estimated average standardized mean difference based on the random-effects model was 0.3033 (95% CI: 0.0605 to 0.5462; P = 0.0144). For Jitter (0.2229; 95% CI: -0.1862 to 0.7986; P = 0.2229) and shimmer (0.2540; 95% CI: -0.1404 to 0.6485; P = 0.2068) there was a trend toward positive values without reaching statistical significance. This meta-analysis confirmed that higher F0 values have been observed in the pediatric population of CI users compared to age-matched normal hearing volunteers, whereas the parameters of voice noise were not significantly different between cases and controls. Prosodic aspects of language need further investigations. In longitudinal contexts, prolonged auditory experience with CI has brought voice parameters closer to the norm. Following the available evidence, we stress the utility of inclusion of vocal acoustic analysis in the clinical evaluation and follow-up of CI patients to optimize the rehabilitation process of pediatric patients with hearing loss.
Read moreOn the relationship between auditory cognition and speech intelligibility in cochlear implant users: An ERP study
On the relationship between auditory cognition and speech intelligibility in cochlear implant users: An ERP study
Relationships Among Peripheral and Central Electrophysiological Measures of Spatial and Spectral Selectivity and Speech Perception in Cochlear Implant Users.
The ability to perceive speech is related to the listener's ability to differentiate among frequencies (i.e., spectral resolution). Cochlear implant (CI) users exhibit variable speech-perception and spectral-resolution abilities, which can be attributed in part to the extent of electrode interactions at the periphery (i.e., spatial selectivity). However, electrophysiological measures of peripheral spatial selectivity have not been found to correlate with speech perception. The purpose of this study was to evaluate auditory processing at the periphery and cortex using both simple and spectrally complex stimuli to better understand the stages of neural processing underlying speech perception. The hypotheses were that (1) by more completely characterizing peripheral excitation patterns than in previous studies, significant correlations with measures of spectral selectivity and speech perception would be observed, (2) adding information about processing at a level central to the auditory nerve would account for additional variability in speech perception, and (3) responses elicited with spectrally complex stimuli would be more strongly correlated with speech perception than responses elicited with spectrally simple stimuli. Eleven adult CI users participated. Three experimental processor programs (MAPs) were created to vary the likelihood of electrode interactions within each participant. For each MAP, a subset of 7 of 22 intracochlear electrodes was activated: adjacent (MAP 1), every other (MAP 2), or every third (MAP 3). Peripheral spatial selectivity was assessed using the electrically evoked compound action potential (ECAP) to obtain channel-interaction functions for all activated electrodes (13 functions total). Central processing was assessed by eliciting the auditory change complex with both spatial (electrode pairs) and spectral (rippled noise) stimulus changes. Speech-perception measures included vowel discrimination and the Bamford-Kowal-Bench Speech-in-Noise test. Spatial and spectral selectivity and speech perception were expected to be poorest with MAP 1 (closest electrode spacing) and best with MAP 3 (widest electrode spacing). Relationships among the electrophysiological and speech-perception measures were evaluated using mixed-model and simple linear regression analyses. All electrophysiological measures were significantly correlated with each other and with speech scores for the mixed-model analysis, which takes into account multiple measures per person (i.e., experimental MAPs). The ECAP measures were the best predictor. In the simple linear regression analysis on MAP 3 data, only the cortical measures were significantly correlated with speech scores; spectral auditory change complex amplitude was the strongest predictor. The results suggest that both peripheral and central electrophysiological measures of spatial and spectral selectivity provide valuable information about speech perception. Clinically, it is often desirable to optimize performance for individual CI users. These results suggest that ECAP measures may be most useful for within-subject applications when multiple measures are performed to make decisions about processor options. They also suggest that if the goal is to compare performance across individuals based on a single measure, then processing central to the auditory nerve (specifically, cortical measures of discriminability) should be considered.
Read moreUsing Neural Response Telemetry to Monitor Physiological Responses to Acoustic Stimulation in Hybrid Cochlear Implant Users.
This report describes the results of a series of experiments where we use the neural response telemetry (NRT) system of the Nucleus cochlear implant (CI) to measure the response of the peripheral auditory system to acoustic stimulation in Nucleus Hybrid CI users. The objectives of this study were to determine whether they could separate responses from hair cells and neurons and to evaluate the stability of these measures over time. Forty-four CI users participated. They all had residual acoustic hearing and used a Nucleus Hybrid S8, S12, or L24 CI or the standard lateral wall CI422 implant. The NRT system of the CI was used to trigger an acoustic stimulus (500-Hz tone burst or click), which was presented at a low stimulation rate (10, 15, or 50 per second) to the implanted ear via an insert earphone and to record the cochlear microphonic, the auditory nerve neurophonic and the compound action potential (CAP) from an apical intracochlear electrode. To record acoustically evoked responses, a longer time window than is available with the commercial NRT software is required. This limitation was circumvented by making multiple recordings for each stimulus using different time delays between the onset of stimulation and the onset of averaging. These recordings were then concatenated off-line. Matched recordings elicited using positive and negative polarity stimuli were added off-line to emphasize neural potentials (SUM) and subtracted off-line to emphasize potentials primarily generated by cochlear hair cells (DIF). These assumptions regarding the origin of the SUM and DIF components were tested by comparing the magnitude of these derived responses recorded using various stimulation rates. Magnitudes of the SUM and DIF components were compared with each other and with behavioral thresholds. SUM and DIF components were identified for most subjects, consistent with both hair cell and neural responses to acoustic stimulation. For a subset of the study participants, the DIF components grew as stimulus level was increased, but little or no SUM components were identified. Latency of the CAPs in response to click stimuli was long relative to reports in the literature of recordings obtained using extracochlear electrodes. This difference in response latency and general morphology of the CAPs recorded was likely due to differences across subjects in hearing loss configuration. The use of high stimulation rates tended to decrease SUM and CAP components more than DIF components. We suggest this effect reflects neural adaptation. In some individuals, repeated measures were made over intervals as long as 9 months. Changes over time in DIF, SUM, and CAP thresholds mirrored changes in audiometric threshold for the subjects who experienced loss of acoustic hearing in the implanted ear. The Nucleus NRT software can be used to record peripheral responses to acoustic stimulation at threshold and suprathreshold levels, providing a window into the status of the auditory hair cells and the primary afferent nerve fibers. These acoustically evoked responses are sensitive to changes in hearing status and consequently could be useful in characterizing the specific pathophysiology of the hearing loss experienced by this population of CI users.
Read moreElectrically evoked auditory cortical responses elicited from individually fitted stimulation parameters in cochlear implant users
Objective To investigate electrically evoked auditory cortical responses (eACR) elicited from the stimulation of intracochlear electrodes based on individually fitted stimulation parameters in cochlear implant (CI) users. Design An eACR setup based on individual fitting parameters is proposed. A 50-ms alternating biphasic pulse train was used to stimulate apical, medial, and basal electrodes and to evoke auditory cortical potentials (N1-P2 complex). Study sample The eACR setup proposed was validated with 14 adult CI users. Results Individual and grand-average eACR waveforms were obtained. The eACR amplitudes were lower in the basal than in the apical and medial regions. Earlier N1 latencies were found in CI users with lower maximum comfortable loudness levels and shorter phase duration in response to apical stimulation, while medial and basal stimulation resulted in earlier N1 latencies and larger N1-P2 amplitudes in users with longer CI experience. Conclusions eACR could be elicited by direct intracochlear stimulation using individual fitting parameters with a success rate of 71%. The highest cortical peak-to-peak amplitudes were obtained in response to apical stimulation. Unlike the P2, the N1 component appeared to be a consistent cortical potential to determine eACR and gain knowledge of the auditory processing beyond the cochlea in CI users. Highlights eACR can be elicited through direct stimulation of intracochlear electrodes. Stimulation of apical and medial regions yielded the highest N1-P2 amplitudes. CI users with lower maximum comfortable loudness levels had shorter N1 latencies during apical stimulation. The present dataset of mainly well-performing CI users suggests better cortical processing, that is, higher amplitudes and shorter latencies of N1. The N1 potential appears a more consistent and reliable potential than the P2 to determine eACR responses in CI users.
Read moreThe effect of delayed auditory feedback (DAF) and frequency altered feedback (FAF) on speech production: cochlear implanted versus normal hearing individuals
ABSTRACTNormal auditory feedback contributes to moment-to-moment control of speech production. Effects of auditory feedback’s absence on hearing-impaired individuals are widely documented, but auditory perturbation has not been investigated. Our objective was to evaluate the effect of delayed auditory feedback (DAF) and frequency altered feedback (FAF) on speech production among prelingual cochlear implant (CI) users and normal hearing (NH) individuals, to evaluate CI users’ reliance on auditory feedback. Twenty young adults (10 CI, 10 NH), without developmental and cognitive impairments, participated in the study. Under variable auditory feedback conditions, speech production (spontaneous or reading aloud) was measured using speech rate, percentage of interruptions, fundamental frequency (F0), and relative intensity. Results showed that (1) both DAF and FAF caused slower speech rates and more interruptions while reading aloud, with DAF having larger effect; (2) altered feedback produced no differences between groups, except an increase in F0 for CI users during DAF; and (3) CI users’ ability to understand speech via phone and without lip-reading was positively correlated with performance under DAF. These findings suggest that auditory perturbation similarly affects speech production among prelingual CI users and NH individuals, indicating CI users depend on auditory feedback to the same degree as normal hearing individuals.
Read moreCombined Brain-Perfusion SPECT and EEG Measurements Suggest Distinct Strategies for Speech Comprehension in CI Users With Higher and Lower Performance.
Cochlear implantation constitutes a successful therapy of inner ear deafness, with the majority of patients showing good outcomes. There is, however, still some unexplained variability in outcomes with a number of cochlear-implant (CI) users, showing major limitations in speech comprehension. The current study used a multimodal diagnostic approach combining single-photon emission computed tomography (SPECT) and electroencephalography (EEG) to examine the mechanisms underlying speech processing in postlingually deafened CI users (N = 21). In one session, the participants performed a speech discrimination task, during which a 96-channel EEG was recorded and the perfusions marker 99mTc-HMPAO was injected intravenously. The SPECT scan was acquired 1.5 h after injection to measure the cortical activity during the speech task. The second session included a SPECT scan after injection without stimulation at rest. Analysis of EEG and SPECT data showed N400 and P600 event-related potentials (ERPs) particularly evoked by semantic violations in the sentences, and enhanced perfusion in a temporo-frontal network during task compared to rest, involving the auditory cortex bilaterally and Broca’s area. Moreover, higher performance in testing for word recognition and verbal intelligence strongly correlated to the activation in this network during the speech task. However, comparing CI users with lower and higher speech intelligibility [median split with cutoff + 7.6 dB signal-to-noise ratio (SNR) in the Göttinger sentence test] revealed for CI users with higher performance additional activations of parietal and occipital regions and for those with lower performance stronger activation of superior frontal areas. Furthermore, SPECT activity was tightly coupled with EEG and cognitive abilities, as indicated by correlations between (1) cortical activation and the amplitudes in EEG, N400 (temporal and occipital areas)/P600 (parietal and occipital areas) and (2) between cortical activation in left-sided temporal and bilateral occipital/parietal areas and working memory capacity. These results suggest the recruitment of a temporo-frontal network in CI users during speech processing and a close connection between ERP effects and cortical activation in CI users. The observed differences in speech-evoked cortical activation patterns for CI users with higher and lower speech intelligibility suggest distinct processing strategies during speech rehabilitation with CI.
Read moreMusical and vocal emotion perception for cochlear implants users
Musical and vocal emotion perception for cochlear implants users
Cochlear Implantation in Deaf Children
A cochlear implant (CI) is a hearing device introduced in the 1980s for profoundly deaf subjects who gained little or no benefit from powerful hearing aids. This device comprises an electrode array inserted in the cochlea, connected to an internal receiver, and an externally worn speech processor. The CI transforms acoustic signals into electrical currents which directly stimulate the auditory nerve. Since the early 1990s, cochlear implantation in children has been developing rapidly. Although it is still difficult to predict how a child will perform with a cochlear implant, the success of cochlear implantation can no longer be denied. In this paper, some recent papers and reports, and the results of the various Nijmegen cochlear implant studies, are reviewed. Issues about selection, examinations, surgery and the outcome are discussed. Overall, our results were comparable with those of other authors. It can be concluded that cochlear implantation is an effective treatment for postlingually deaf as well as prelingually (congenital or acquired) deaf children with profound bilateral sensorineural deafness.
Read moreFundamental frequency is critical to speech perception in noise in combined acoustic and electric hearing
Cochlear implant (CI) users have been shown to benefit from residual low-frequency hearing, specifically in pitch related tasks. It remains unclear whether this benefit is dependent on fundamental frequency (F0) or other acoustic cues. Three experiments were conducted to determine the role of F0, as well as its frequency modulated (FM) and amplitude modulated (AM) components, in speech recognition with a competing voice. In simulated CI listeners, the signal-to-noise ratio was varied to estimate the 50% correct response. Simulation results showed that the F0 cue contributes to a significant proportion of the benefit seen with combined acoustic and electric hearing, and additionally that this benefit is due to the FM rather than the AM component. In actual CI users, sentence recognition scores were collected with either the full F0 cue containing both the FM and AM components or the 500-Hz low-pass speech cue containing the F0 and additional harmonics. The F0 cue provided a benefit similar to the low-pass cue for speech in noise, but not in quiet. Poorer CI users benefited more from the F0 cue than better users. These findings suggest that F0 is critical to improving speech perception in noise in combined acoustic and electric hearing.
Read more