• Home
  • Search
  • Properties Of Iterative Algorithms In SPECT Image Reconstruction
  • Cite Icon2
  • https://doi.org/10.1109/nssmic.1990.693588Copy DOI Icon

Properties Of Iterative Algorithms In SPECT Image Reconstruction

  • Oct 22, 1990
  • B.m.w Tsui +3 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

We studied the properties of two iterative reconstruction algorithms, namely the ML-EM and the WLSCG algorithms, for use in compensation for attenuation and detector response in cardiac SPECT. A realistic phantom, derived from a patient X-ray CT image to simulate 201T1 SPECT data, was used in the study. Both algorithms are effective in compensating for the non-uniform attenuation distribution in the thorax region and the spatially variant detector response function of the imaging system. At low iteration numbers, additional compensation for detector response provides improvement in both spatial resolution and image noise when compared with attenuation compensation alone. However, at higher iteration numbers, there is a more rapid increase in image noise when detector response compensation is included, and the increase is more dramatic for WLS-CG algorithm. In general, the initial convergence rate of the WLS-CG algorithm is about ten times that of the ML-EM algorithm. Also, the WLS-CG exhibits a faster increase in image noise at large iteration numbers than the ML-EM algorithm. The investigation provides valuable information about the choice of iterative algorithms and optimum iteration number for improved cardiac SPECT image reconstruction.

Similar Papers
  • Research Article
  • Citations1

Delayed convergence of iterative reconstruction in dopamine transporter SPECT with multiple-pinhole collimators.

  • Nov 01, 2025
  • Zeitschrift fur medizinische Physik
  • Loreen Jedid +9
  • Research Article
  • Citations148

Investigation of the use of X-ray CT images for attenuation compensation in SPECT

  • Dec 01, 1994
  • IEEE Transactions on Nuclear Science
  • K.J Lacroix +3
  • Book Chapter

An Analytical Approach of Compensation for Non-Uniform Attenuation and 3D Detector Response in Cardiac SPECT Imaging

  • Jan 01, 1996
  • S J Glick +3
  • Conference Article
  • Citations12

Characteristics of proton CT images reconstructed with filtered backprojection and iterative projection algorithms

  • Oct 01, 2009
  • S.N Penfold +4
  • Research Article
  • Citations62

Detection of coronary calcifications: feasibility of dose reduction with a body weight-adapted examination protocol.

  • Aug 01, 2003
  • American Journal of Roentgenology
  • A H Mahnken +6
  • Research Article
  • Citations5

Effect of blood glucose and body weight on image quality in brain [18F]FDG PET imaging.

  • Aug 27, 2020
  • Nuclear Medicine Communications
  • Otto M Henriksen +3
  • Research Article
  • Citations298

Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape.

  • Sep 09, 2004
  • Radiology
  • Marilyn J Siegel +4
  • Research Article
  • Citations10

Analysis of the influence of coordinate and dynamic formulations on solving biomechanical optimal control problems

  • Aug 02, 2019
  • Mechanism and Machine Theory
  • Gil Serrancolí +1
  • Research Article
  • Citations10

Leak Detection Modeling and Simulation for Oil Pipeline with Artificial Intelligence Method

  • Jan 01, 2007
  • ITB Journal of Engineering Science
  • Pudjo Sukarno +5
  • Research Article
  • Citations16

Reducing radiation dose and enhancing imaging quality of 4DCT for radiation therapy using iterative reconstruction algorithms

  • Apr 22, 2017
  • Advances in Radiation Oncology
  • George Noid +4
  • Research Article
  • Citations11

Dünn- und dickschichtige MSCT-Untersuchungen bei Niedrigkontrastobjekten (Leberläsionen): Vergleich der Bildqualität bei gleicher Dosis

  • Nov 01, 2004
  • RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
  • U Wedegärtner +7
  • Conference Article
  • Citations3

Reconstruction of truncated TCT and SPECT data from a right-angle dual-camera system for myocardial SPECT

  • Nov 02, 1996
  • B.M.W Tsui +3
  • Research Article
  • Citations23

Image quality of low-dose CCTA in obese patients: impact of high-definition computed tomography and adaptive statistical iterative reconstruction

  • Apr 28, 2013
  • The International Journal of Cardiovascular Imaging
  • Cathérine Gebhard +6
  • Research Article
  • Citations96

Virtual Nonenhanced Dual-Energy CT Urography with Tin-Filter Technology: Determinants of Detection of Urinary Calculi in the Renal Collecting System

  • May 08, 2012
  • Radiology
  • Stefanie Mangold +8
  • Research Article
  • Citations9

Evaluation of a novel collimator for molecular breast tomosynthesis.

  • Oct 13, 2017
  • Medical Physics
  • David R Gilland +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.