• Home
  • Search
  • Pulse Pile-up Rejection in Energy Dispersive XRF Analysis
  • Cite Icon1
  • https://doi.org/10.1109/elnano54667.2022.9927017Copy DOI Icon

Pulse Pile-up Rejection in Energy Dispersive XRF Analysis

  • Oct 10, 2022
  • Pavlo Vysotskyi +3 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

XRF analysis allows for quick and accurate evaluation of chemical composition of wide range of materials, and is actively used in different fields of science and industry. The accuracy of a measurement depends on number of counts recorded to spectrum, and can be improved either by extending the measurement time, which is unwelcome especially when analyzing a large amount of samples, or by increasing the count rate of spectrometer. The latter however leads to parasitic effects due to pulse pile-up caused by detectors finite resolving time. When acquiring XRF spectrum at high count rates with semiconductor detectors pulse pile-up leads to distortion of recorded spectrum, in particular to appearance of so-called pile-up peaks. Pile-up peaks appear due to detector being unable to separate two or more incident quanta arriving in time interval less than detectors resolving time, and recording them as a single quantum with energy that equals to sum of incident quanta energies. If not accounted for pile-up peaks may lead to quantitative and qualitative errors while making composition calculations based on the recorded spectrum. In this article the statistic of pile-up peaks in XRF spectra, their dependence on spectrum acquisition parameters and ways of improvement of pulse pile-up rejection algorithms are considered. Experimental data was acquired using Elvatech Prospector 3 spectrometer. A high dependency of spectrometers resolving time on quanta energies was observed. Based off experimental data an improvement to pile-up rejection algorithm was proposed.

Similar Papers
  • Research Article
  • Citations4

Elimination of distortions of nuclear energy spectra caused by pulse pile-up

  • Dec 01, 1994
  • Measurement Science and Technology
  • V Drndarevic
  • Research Article

A method combining pulse shape discrimination and pile-up rejection for plastic scintillator detectors based on multiresolution analysis

  • Apr 01, 2025
  • Journal of Instrumentation
  • Jingxin Zuo +6
  • Research Article

Evaluation of Pulse Pileup Rejection

  • Jan 01, 1977
  • Advances in X-ray Analysis
  • John C Russ +1
  • Conference Article

Application of a post-acquisition pileup correction algorithm to high count rate Ge spectra

  • Oct 25, 1992
  • Q Bristow
  • Research Article
  • Citations28

Liquid-scintillation spectroscopy of α-particle emitters and detection of spontaneous fission events for on-line studies of actinide and transactinide elements

  • Feb 01, 1996
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • B Wierczinski +12
  • Conference Article
  • Citations10

Performance Assessment of Pixelated LaBr3 Detector Modules for TOF PET

  • Oct 16, 2004
  • A Kuhn +5
  • Research Article
  • Citations14

Investigations for the use of the fast digitizers with [formula omitted] detectors for radiative capture measurements at GELINA

  • Dec 07, 2008
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • L.C Mihailescu +3
  • Conference Article
  • Citations2

Analytical model for pulse pileup in photon counting detectors with seminonparalyzable behavior

  • Feb 15, 2021
  • Yirong Yang +2
  • Research Article
  • Citations21

High photon count rates improve the quality of super-resolution fluorescence fluctuation spectroscopy

  • Feb 13, 2020
  • Journal of Physics D
  • Falk Schneider +9
  • Research Article
  • Citations17

A spectrometer with baseline correction and fast pulse pile-up rejection for prompt gamma neutron activation analysis technology.

  • Dec 01, 2018
  • Review of Scientific Instruments
  • Xiaodong Zhong +3
  • Conference Article
  • Citations9

A count rate-dependent method for spectral distortion correction in photon counting CT

  • Jan 01, 2018
  • Medical Imaging 2018: Physics of Medical Imaging
  • Jannis Dickmann +6
  • PDF
  • Research Article
  • Citations85

A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon‐counting x‐ray detector for CT

  • Mar 11, 2014
  • Medical Physics
  • Jochen Cammin +5
  • Book Chapter
  • Citations2

Samples and Standards

  • Jan 01, 2004
  • Richard M Lindstrom +1
  • Research Article
  • Citations1

Fuel Rod Scanner for Reactor Power Density Distribution Measurement

  • Jan 01, 1965
  • Journal of Nuclear Science and Technology
  • Setsuo Kobayashi +1
  • Research Article
  • Citations1

Pulse pile-up correction by auto-regression on linear operations (ARLO) method: A comparison with integration-based algorithms

  • May 01, 2024
  • Nuclear Engineering and Technology
  • Mohammad-Reza Mohammadian-Behbahani
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.