• Home
  • Search
  • Pulsecal: A valuable tool, but cautio consilium for use in deuterated organic solvents
  • https://doi.org/10.26434/chemrxiv-2025-h1h9sCopy DOI Icon

Pulsecal: A valuable tool, but cautio consilium for use in deuterated organic solvents

Show More
  • Abstract
  • Literature Map
  • Similar Papers
Abstract

Stroboscopic nutation (P. S. C. Wu; G. Otting, Rapid pulse length determination in high-resolution NMR. J. Magn. Reson. 2005, 176(1), 115–119) has proved to be invaluable for the rapid calibration of observation pulse widths, particularly for the 1H nucleus. Originally intended for aqueous solutions, especially for lossy samples and with a high protiated content of the solvent, application of the technique has been extended to all types of samples as well as other nuclei. Herein it is shown that pulsecal – the automated subroutine that performs stroboscopic nutation on Bruker instruments – can perform poorly for deuterated organic solvents and how this can be recognized. Conversely, it is shown under which circumstances pulsecal can perform well for deuterated organic solvents. But awareness of how pulsecal performs and knowing what a meaningful result should look like, how to extract meaningful values from a pulsecal spectral output, or how to direct pulsecal to use a suitable signal for measurement can all help avoid errant results. Thus it is important to evaluate the output of pulsecal to ensure it is correctly returning meaningful values. This need not be done on all samples but checks on a representative sample of a sample set or type of samples are recommended. Hence, when using pulsecal to measure pulse widths in deuterated organic solvents, cautio consilium (caution advised).

Similar Papers
  • Research Article
  • Citations16

A 3D-Printed Offline Nano-ESI Source for Bruker MS Instruments.

  • Aug 21, 2023
  • Journal of the American Society for Mass Spectrometry
  • Michael Götze +3
  • Preprint Article

Analytical Assessment of Metagenomic Workflows for Pathogen Detection with NIST RM 8376 and Two Sample Matrices

  • Sep 26, 2024
  • bioRxiv (Cold Spring Harbor Laboratory)
  • Jason G Kralj +5
  • Discussion
  • Citations143

Saliva as a gold-standard sample for SARS-CoV-2 detection

  • Apr 19, 2021
  • The Lancet. Respiratory Medicine
  • Steph H Tan +3
  • Research Article
  • Citations3

Effects of laser conditioning with different pulse widths on picosecond laser-induced damage resistance in HfO2/SiO2 high-reflectivity coatings

  • Jun 04, 2025
  • Optical Materials Express
  • Yan Zhou +11
  • Research Article
  • Citations9

Self-organising maps for the exploration and classification of thin-layer chromatograms

  • May 13, 2021
  • Talanta
  • Matthias Guggenberger +4
  • Research Article
  • Citations3

Non-invasive pre-implantation genetic testing's reliability for aneuploidy using Cell-free DNA in embryo culture media

  • May 31, 2024
  • Journal of Gynecology Obstetrics and Human Reproduction
  • Nining Handayani +9
  • Conference Article
  • Citations7

Modified Pyrolytic Carbon Black from Scrap Tires and Its Reinforcement Performance in Natural Rubber

  • Feb 01, 2011
  • Zhou Jie +3
  • Research Article
  • Citations100

Identification of Lignin and Polysaccharide Modifications in Populus Wood by Chemometric Analysis of 2D NMR Spectra from Dissolved Cell Walls

  • Sep 01, 2009
  • Molecular Plant
  • Mattias Hedenström +7
  • Research Article
  • Citations104

Rapid pulse length determination in high-resolution NMR

  • Jun 21, 2005
  • Journal of Magnetic Resonance
  • Peter S.C Wu +1
  • Research Article

Abstract 3377: Simultaneous analysis of the mutational landscape and RNA and protein expression profile of HER2-positive breast cancer using 3D BiologyTM

  • Jul 01, 2017
  • Cancer Research
  • Sarayna Chumsri +15
  • Research Article
  • Citations37

Comparison of Headspace GC and Electronic Sensor Techniques for Classification of Processed Orange Juices

  • Aug 01, 2000
  • LWT - Food Science and Technology
  • Philip E Shaw +5
  • Research Article
  • Citations2

YIELD STUDIES IN OATS

  • Nov 01, 1927
  • Annals of Applied Biology
  • M A H Tincker +1
  • Abstract

P 230. Third generation controllable pulse parameter transcranial magnetic stimulation device

  • Aug 30, 2013
  • Clinical Neurophysiology
  • A Peterchev +1
  • Research Article
  • Citations2

Experiences of Production and Homogeneity Analysis of an AMS 14C Sucrose Standard for High-Activity Measurements

  • Jan 01, 2010
  • Radiocarbon
  • Marie Sydoff +1
  • Research Article

VALORIZACIÓN DE SUBPRODUCTOS ENOLÓGICOS Y SU APROVECHAMIENTO PARA LA ELABORACIÓN DE BEBIDAS FERMENTADAS TIPO KOMBUCHA

  • Mar 21, 2025
  • Anales de Veterinaria de Murcia
  • Elena Alcaraz-Férez +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.