• Home
  • Search
  • Q-hour meter performance under unbalanced voltage supply
  • Cite Icon4
  • https://doi.org/10.1109/ichqp.1998.760197Copy DOI Icon

Q-hour meter performance under unbalanced voltage supply

  • Oct 14, 1998
  • Y Baghzouz +1 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

This article investigates the error associated with reactive power and power factor when calculated from a set of watt-hour and Q-hour meters in a circuit where an unbalanced sinusoidal supply feeds a linear balanced load. An analytical expression of the error is derived in terms of the level of voltage unbalance. It is found that this method under-estimates reactive power thus leading to higher power factor at all times but the error is well within meter tolerance for typical levels of unbalance.

Similar Papers
  • Conference Article
  • Citations2

Predictive Tuned Filter based Reference Current Generation for Shunt Active Power Filter under Distorted and Unbalanced Supply Voltage

  • Mar 01, 2018
  • Vijayakumar Gali +2
  • Conference Article
  • Citations2

Limitation of adjustable-speed drive operation by unbalanced voltage supply

  • Sep 01, 2008
  • Miroslav Chomat +2
  • Research Article
  • Citations10

Extension of the CPC power theory to four-wire power systems with non-sinusoidal and unbalanced voltages

  • Aug 30, 2018
  • International Journal of Electrical Power & Energy Systems
  • Bojana Škrbić +2
  • Conference Article
  • Citations7

Automatic Optimization and Control of Power Factor, Reactive Power and Reduction of THD for Linear and Nonlinear Load by Using Arduino UNO

  • Apr 01, 2018
  • Saurabh B Jarad +3
  • Research Article
  • Citations4

Average value of the DC-link output voltage in multi-phase uncontrolled bridge rectifiers under supply voltage balance and unbalance conditions

  • May 03, 2021
  • Electrical Engineering
  • Jaume Saura +2
  • Research Article
  • Citations5

A Proposed Approach for Separation between Short Circuit Fault, Magnetic Saturation Phenomenon and Supply Unbalance in Permanent Magnet Synchronous Motor

  • Oct 01, 2020
  • International Journal of Engineering
  • Zakaria Gherabi +3
  • Conference Article
  • Citations2

Unbalance supply and its effect on rectifier input filter kVA ratings

  • Mar 10, 1991
  • A.I Maswood +1
  • Conference Article
  • Citations3

Power converters under voltage imbalance-a novel solution

  • Sep 10, 2001
  • G Paulillo +1
  • Conference Article
  • Citations2

Active front-end of electric drive under unbalanced voltage supply

  • Jun 01, 2010
  • M Chomat +2
  • Conference Article
  • Citations7

Stator fault detection in induction motor under unbalanced supply voltage

  • Jul 01, 2014
  • Anju Jacob +2
  • Research Article
  • Citations5

ANALISIS PEMBACAAN METER OTOMATIS LISTRIK DENGAN MENGGUNAKAN JARINGAN KOMUNIKASI

  • Aug 22, 2015
  • Rinna Hariyati
  • Research Article

Intelligent-based AT-SHAPF control for enhanced power quality in SOFC-driven hybrid system

  • Oct 02, 2025
  • Scientific Reports
  • Yerramala Jagadeesh +1
  • Research Article

Adaptive filter based current controller for Shunt Active filter

  • Apr 25, 2018
  • International Journal of Engineering & Technology
  • R Sriranjani +1
  • Research Article

Analysis of three types of power and the power factor in RLC circuits

  • Jan 01, 2025
  • Journal of Physics: Conference Series
  • Yueshan Xiao
  • Research Article

Simplified Models of Harmonics Produced by Twelve-Pulse AC/DC Converters under Unbalanced Supply Voltage

  • Jan 01, 2005
  • International Journal of Power and Energy Systems
  • É Ngandui +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.