• Home
  • Search
  • Quantification and reduction of the collimator-detector response effect in SPECT by applying a system model during iterative image reconstruction
  • Cite Icon8
  • https://doi.org/10.1097/mnm.0b013e32834e755fCopy DOI Icon

Quantification and reduction of the collimator-detector response effect in SPECT by applying a system model during iterative image reconstruction

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Detector blurring and non-ideal collimation decrease the spatial resolution of the single-photon emission computed tomography (SPECT) images. Iterative reconstruction algorithms such as ordered subsets expectation maximization (OSEM) can incorporate degrading factors during reconstruction. We investigated the quantitative errors associated with poor SPECT resolution and evaluated the importance of two-dimensional (2D) and three-dimensional (3D) resolution recovery by modelling system response during iterative image reconstruction. Different phantoms consisted of the NURBS-based cardiac-torso (NCAT) liver phantom with small tumors, the Zubal brain phantom and the NCAT heart phantom were used in this study. Monte Carlo simulation was used to create SPECT projections. Gaussian functions were used to model collimator detector response (CDR). Modeled CDRs were applied during OSEM. Both noise-free and noisy projections were created. Even with noise-free projections, conventional OSEM algorithm provided limited quantitative accuracy compared to both 2D and 3D resolution recovery. The 3D implementation of resolution recovery, however, yielded superior results compared to its 2D implementation. For the liver phantom, the ability to distinguish small tumors in both transverse and axial planes was improved. For the brain phantom, gray to white matter activity ratio was increased from 3.14 ± 0.04 in simple OSEM to 3.84 ± 0.06 in 3D OSEM. For the NCAT heart phantom, 3D resolution recovery, results in images with thinner wall and higher contrast for different noise levels. There are considerable quantitative errors associated with CDR, especially when the size of the target is comparable with the spatial resolution of the system. Between different reconstruction algorithms, 3D OSEM that consider the 3D nature of CDR, improve both the visual quality and the quantitative accuracy of any SPECT studies.

Similar Papers
  • Research Article
  • Citations3

Evaluation of Image Reconstruction Techniques in Single Photon Emission Computed Tomography (SPECT/CT) Imaging

  • Apr 20, 2018
  • Research & Reviews: Journal of Physics
  • F Usman +3
  • Research Article
  • Citations5

Optimization of the filter parameters in 99mTc myocardial perfusion SPECT studies: the formulation of flowchart

  • Apr 06, 2016
  • Australasian Physical & Engineering Sciences in Medicine
  • Takayuki Shibutani +7
  • Research Article
  • Citations42

Accuracy and Reproducibility of Myocardial Blood Flow Quantification by Single Photon Emission Computed Tomography Imaging in Patients With Known or Suspected Coronary Artery Disease.

  • Jun 01, 2022
  • Circulation. Cardiovascular imaging
  • Ana Carolina Do A H De Souza +18
  • PDF
  • Research Article
  • Citations1

Effect of data conserving respiratory motion compensation on left ventricular functional parameters assessed in gated myocardial perfusion SPECT

  • Jan 21, 2021
  • EJNMMI Physics
  • Matti J Kortelainen +3
  • PDF
  • Research Article

Missing head and color banding in low-count SPECT reconstructions

  • Sep 08, 2014
  • EJNMMI Physics
  • Robin De Nijs +2
  • Research Article
  • Citations15

The Value of Attenuation Correction in Hybrid Cardiac SPECT/CT on Inferior Wall According to Body Mass Index

  • Jan 01, 2016
  • World Journal of Nuclear Medicine
  • Muge Tamam +3
  • Research Article
  • Citations2

Evaluation and reduction of respiratory motion artifacts in small animal SPECT with GATE

  • Sep 14, 2015
  • Journal of Instrumentation
  • C.-L Lee +2
  • Research Article
  • Citations6

SPECT Imaging With Resolution Recovery

  • Aug 01, 2012
  • IEEE Transactions on Nuclear Science
  • Andrei V Bronnikov
  • Research Article
  • Citations17

Feasibility of ultra-high-speed acquisition in xSPECT bone algorithm: a phantom study with advanced bone SPECT-specific phantom.

  • Nov 03, 2021
  • Annals of Nuclear Medicine
  • Hajime Ichikawa +6
  • PDF
  • Research Article
  • Citations3

Advanced quantitative evaluation of PET systems using the ACR phantom and NiftyPET software

  • Mar 31, 2022
  • Medical Physics
  • Pawel J Markiewicz +18
  • PDF
  • Research Article
  • Citations21

Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study

  • Sep 21, 2015
  • PLoS ONE
  • Oliver S Grosser +9
  • Research Article
  • Citations6

Design of a high-resolution small-animal SPECT-CT system sharing a CdTe semiconductor detector

  • Jul 01, 2012
  • Journal of the Korean Physical Society
  • Hyun-Ju Ryu +5
  • Research Article
  • Citations21

Determination of optimal regularization factor in Bayesian penalized likelihood reconstruction of brain PET images using [18 F]FDG and [11 C]PiB.

  • Mar 14, 2022
  • Medical Physics
  • Kei Wagatsuma +13
  • Research Article
  • Citations1

Effects of PET image reconstruction parameters and tumor-to-background uptake ratio on quantification of PET images from PET/MRI and PET/CT systems

  • Sep 27, 2024
  • Brazilian Journal of Radiation Sciences
  • Amena Ali Hussain +3
  • Research Article
  • Citations13

Fusion of the MR image to SPECT with possible correction for partial volume effects

  • Feb 01, 2006
  • IEEE Transactions on Nuclear Science
  • P Calvini +3
Cactus Communications logo