Quantification of bone microarchitecture using photon-counting CT at different radiation doses: A comparison with µCT

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

PurposeAccurate measurements of trabecular bone microarchitecture are required for a proper assessment of bone fragility. Photon-counting detector CT (PCD-CT) has different technical properties than conventional CT, resulting in higher resolution and thereby potentially enabling in-vivo measurement of trabecular microarchitecture. The purpose of this study was to quantify trabecular bone microarchitectural parameters with PCD-CT at varying radiation doses and compare this to µCT as gold standard. MethodBoth distal radii, distal tibiae, femoral heads, and two vertebrae were dissected from one human. All specimens were scanned ex-vivo on a PCD-CT system (slice increment 0.1 mm; pixel size 0.1042–0.127 mm) and a µCT system (isotropic voxel size 49–68.4 µm). The radiation doses of the PCD-CT scans were varied from 2.5 to 120 mGy based on the volume CT dose index (CTDIvol32). For the PCD-CT scans, contrast-to-noise ratio and trabecular sharpness were calculated and compared between radiation doses. µCT and PCD-CT scans were registered. The trabecular bone was then segmented from all PCD-CT and µCT scans and split into cubes with 6-mm edge length. For each cube, bone volume over total volume, trabecular thickness, trabecular number, and trabecular heterogeneity were calculated and compared between corresponding PCD-CT and µCT cubes. ResultsWith increasing dose, contrast-to-noise ratio and trabecular sharpness values increased for the PCD-CT images. Already at the lowest dose, high correlations between the trabecular microarchitectural parameters between µCT and PCD-CT were found (R2 = 0.55–0.95), which improved with increasing radiation dose (R2 = 0.76–0.96 at 20 mGy). ConclusionsPCD-CT can be used to quantify trabecular bone microarchitecture, with accuracy comparable to µCT and at clinically relevant radiation doses.

Similar Papers
  • Research Article
  • Citations8

Photon-Counting Detector CT With Denoising for Imaging of the Osseous Pelvis at Low Radiation Doses: A Phantom Study.

  • Nov 22, 2023
  • AJR. American journal of roentgenology
  • Roy P Marcus +5
  • PDF
  • Research Article
  • Citations2

Comparative analysis of photon-counting and energy-integrating detector CT to identify obstructive coronary artery disease.

  • Nov 14, 2025
  • European radiology
  • Melinda Boussoussou +17
  • PDF
  • Research Article
  • Citations2

Ultra-high-resolution imaging of intracranial flow diverters with photon counting CT: A comparative phantom study with flat-panel CT.

  • Jul 21, 2025
  • Scientific reports
  • Christoph Johannes Maurer +6
  • PDF
  • Research Article
  • Citations9

Reduction of radiation exposure and preserved image quality using photon-counting detector cardiac computed tomography without electrocardiographic gating in children with congenital heart disease

  • Jul 03, 2025
  • European Radiology
  • Susanne Hellms +12
  • Research Article
  • Citations8

Reducing contrast media and radiation dose in CT angiography at low tube voltage: animal study with photon-counting detector CT

  • Mar 24, 2025
  • European Radiology Experimental
  • Konstantin Klambauer +8
  • Research Article
  • Citations7

Photon-counting detector CT - first experiences in the field of musculoskeletal radiology.

  • May 24, 2024
  • RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin
  • Stefanie Bette +9
  • PDF
  • Research Article
  • Citations1

Low-tube-potential ultra-high-resolution coronary CTA with photon-counting detector CT for stent evaluation: a comparative feasibility study

  • Jan 01, 2025
  • Japanese Journal of Radiology
  • Suguru Araki +6
  • Research Article
  • Citations19

Photon-counting Detector CT for Liver Fat Quantification: Validation across Protocols in Metabolic Dysfunction-associated Steatotic Liver Disease.

  • Sep 01, 2024
  • Radiology
  • Huimin Lin +6
  • Research Article
  • Citations11

Photon-Counting Detector CT for Femoral Stent Imaging in an Extracorporeally Perfused Human Cadaveric Model.

  • Oct 07, 2023
  • Investigative radiology
  • Viktor Hartung +10
  • Research Article
  • Citations5

Single-Energy, Dual-Energy, and Photon-Counting Computed Tomography of the Liver: Current Development and Clinical Utility for the Assessment of Focal Liver Lesions.

  • Mar 01, 2026
  • Investigative radiology
  • Shintaro Ichikawa +9
  • Research Article

A Practical Rule-of-Thumb to Adapt Contrast Media Dose in Photon-counting Detector CT: The 10-to-5 Rule.

  • Nov 26, 2025
  • Investigative radiology
  • Cécile R L P N Jeukens +6
  • Research Article
  • Citations16

Image quality of photon counting and energy integrating chest CT – Prospective head-to-head comparison on same patients

  • Jul 26, 2023
  • European journal of radiology
  • Fides R Schwartz +12
  • Research Article
  • Citations1

Diagnostic performance of photon-counting detector CT versus energy-integrating detector CT for colorectal polyp detection: a phantom study.

  • Feb 09, 2026
  • Abdominal radiology (New York)
  • Xiaofei Wu +7
  • Research Article
  • Citations39

Diagnostic Performance of Decubitus Photon-Counting Detector CT Myelography for the Detection of CSF-Venous Fistulas.

  • Nov 09, 2023
  • AJNR. American journal of neuroradiology
  • Ajay A Madhavan +15
  • Research Article
  • Citations5

Ultra-high-resolution photon-counting detector CT for visualization of the brachial plexus

  • Oct 30, 2024
  • European Journal of Radiology
  • Masahiro Nakashima +7
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.