• Home
  • Search
  • Radiation dose reduction without degrading image quality during computed tomography examinations: Dosimetry and quality control study
  • Cite Icon4
  • https://doi.org/10.14319/ijcto.0203.9Copy DOI Icon

Radiation dose reduction without degrading image quality during computed tomography examinations: Dosimetry and quality control study

Show More
  • Abstract
  • Highlights & Summary
  • PDF
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Purpose: Computed tomography (CT), is an X-ray procedure that generates high quality cross-sectional images of the body, and by comparison to other radiological diagnosis, is responsible for higher doses to patients. This work studies the doses and image qualities produced from the default primary scanning factors of a Siemens CT machine and afterwards came up with scanning protocols that allow radiologists to obtain the necessary diagnostic information while reducing radiation doses to as low as reasonably achievable. Methods : Approximately 1000 CT scans from mostly common examinations; head, thorax, abdomen and pelvis routines were selected and analyzed for their image quality and radiation doses over a two year interval. Dose measurements were performed for the same routines using Computed Tomography Dose Index (CTDI) phantoms, RTI barracuda system with electrometer, and CT dose Profiler detector to evaluate the doses delivered during these CT procedures. Subsequently, image quality checks were performed using the CT Catphan 600 and anthropomorphic phantoms. CTDI and Dose Length Product (DLP) values were calculated for each scan. From analyzing these measurements, the appropriate machine scanning parameters were adjusted to reduce radiation does while at the same time providing good image quality. Results: Doses to patients using the default head sequence protocol had an average CTDI vol value of 65.45 mGy and a range of 7.10-16.80 mGy for thorax, abdomen and pelvis examinations whiles the new protocol had an average CTDI vol of 58.32 mGy for the head and a range of 3.83-15.24 mGy for the truck region. The DLP value for default head scans decreased from an average of 2279.85 mGy.cm to 874.53 mGy.cm with the new protocol. Tube potentials (KV) and tube current-time (mAs) had an effect on spatial resolution and low contrast detectability as well as doses. Conclusion : From the new protocols, lower values of KV and mAs together with other factors were enough to produce acceptable level of image quality which leads to adequate diagnosis without unnecessary doses to patients. ...................................................... Cite this article as: Acquah GF, Schiestl B,Cofie AY, Nkansah JO. Radiation dose reduction without degrading image quality during computed tomography examinations: Dosimetry and quality control study. Int J Cancer Ther Oncol 2014; 2 (3):02039. DOI: 10.14319/ijcto.0203.9

Loading PDF

Similar Papers
  • Research Article
  • Citations9

Reducing the radiation dose with the adaptive statistical iterative reconstruction technique for chest CT in adults: a parameter study

  • Apr 05, 2014
  • Chinese Medical Journal
  • Wenyun Liu +4
  • Research Article
  • Citations444

CT Dose Index and Patient Dose: They AreNotthe Same Thing

  • May 01, 2011
  • Radiology
  • Cynthia H Mccollough +5
  • Research Article
  • Citations10

Adaptive statistical iterative reconstruction use for radiation dose reduction in pediatric lower-extremity CT: impact on diagnostic image quality.

  • Dec 26, 2017
  • Skeletal Radiology
  • Amisha Shah +5
  • PDF
  • Research Article
  • Citations20

Establishment of local diagnostic reference levels for common adult CT examinations: a multicenter survey in Addis Ababa

  • Jan 09, 2023
  • BMC Medical Imaging
  • Marema Jebessa Kumsa +5
  • Research Article
  • Citations7

Evaluation of Dose Reduction and Image Quality in Pediatric Multi-Detector CT

  • Jul 15, 2010
  • Journal of the Korean Physical Society
  • Seung-Wan Lee +3
  • Research Article
  • Citations13

Combination of Adaptive Statistical Iterative Reconstruction-V and Lower Tube Voltage During Craniocervical Computed Tomographic Angiography Yields Better Image Quality with a Reduced Radiation Dose

  • Sep 05, 2018
  • Academic Radiology
  • Chih-Wei Chen +6
  • Research Article

Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality

  • Sep 01, 2020
  • Iranian Journal of Medical Physics
  • Nnamdi Okoro +3
  • Research Article
  • Citations6

Automatic radiation dose monitoring for CT of trauma patients with different protocols: feasibility and accuracy

  • May 24, 2016
  • Clinical Radiology
  • K Higashigaito +5
  • Conference Article
  • Citations4

National survey on medical exposure to patients undergoing diagnostic radiology examinations: An initial overview on CT doses at UAE hospitals

  • Feb 01, 2011
  • Jamila Salem Alsuwaidi +7
  • Research Article

Application of Care kV combined with Care Dose 4D in abdominal CT

  • Jan 25, 2017
  • Zhonghua fangshe yixue yu fanghu zazhi
  • Weiguo Zhang
  • Research Article
  • Citations44

Radiation dose reduction with the adaptive statistical iterative reconstruction (ASIR) technique for chest CT in children: An intra-individual comparison

  • Jul 12, 2012
  • European Journal of Radiology
  • Seung Hyun Lee +3
  • Research Article

Investigation on effect of dual-source CT scanning patterns on radiation dose and image quality of head and neck

  • Dec 25, 2016
  • Zhonghua fangshe yixue yu fanghu zazhi
  • Yinong Niu +2
  • Research Article
  • Citations2

Radiation Exposure of Ovarian Cancer Patients: Contribution of CT Examinations Performed on Different MDCT (16 and 64 Slices) Scanners and Image Quality Evaluation

  • May 01, 2015
  • Medicine
  • Stefania Rizzo +7
  • Research Article
  • Citations298

Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape.

  • Sep 09, 2004
  • Radiology
  • Marilyn J Siegel +4
  • Research Article

Assessment of compliance levels of effective doses in pediatric CT

  • Dec 01, 2018
  • Iranian Journal of Medical Physics
  • Dheyauldeen Shabeeb +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.