• Cite Icon30
  • https://doi.org/10.1109/noms.2012.6211885Copy DOI Icon

Ranking anomalies in data centers

  • Apr 1, 2012
  • K Viswanathan +5 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Data centers are growing in size and complexity driven by trends such as cloud computing and on-line services. Such large data centers pose several challenges for system management. Key among them is anomaly detection which is required to monitor and analyze metrics across several thousands servers and across multiple layers of abstractions to detect anomalous system behavior. In practice, multiple anomaly detection tools are used to continuously raise alarms across multiple metrics and servers. These alarms include both true positives and false alarms. Administrators and management tools act on these alarms for diagnosis and deeper root cause analysis and take appropriate management actions to mitigate the anomalous behaviors. Given the scale and scope of the system, the administrators and management tools are overwhelmed with the large number of alarms at any given instant, many of which are false alarms. It is therefore necessary to prioritize and rank these alarms, so as to take timely actions that maintain the service level agreements for the data center. Existing techniques for such ranking are ad-hoc and not scalable. We propose ranking windows of monitored metrics based on their probability of occurrence. We explain how these probabilities can be computed based either on the false positive rates for which the accompanying anomaly detectors were designed, or, when available, on the probability models underlying the false positive rates. In the simplest case, the ranking procedure reduces to computing the Z-score of the observed measurements and computing a statistic from a window of Z-scores to use as a basis for ranking. The proposed techniques are reliable, lightweight and easy to deploy in the modern data center. We have validated these techniques on synthetic data containing injected anomalies and on data acquired from production data centers.

Similar Papers
  • Conference Article
  • Citations29

Characterizing Disk Failures with Quantified Disk Degradation Signatures: An Early Experience

  • Oct 01, 2015
  • Song Huang +3
  • Research Article
  • Citations17

Wireless Data Center Management: Sensor Network Applications and Challenges

  • Nov 01, 2014
  • IEEE Microwave Magazine
  • Rahul Khanna +2
  • Conference Article
  • Citations2

Perimeter Cooling Unit and Localized Row-Based Cooling Unit Transient Air Flow Effects Modeling and Characterization in Data Centers

  • Nov 13, 2015
  • Tianyi Gao +4
  • Research Article
  • Citations57

Logistics and cloud computing service providers’ cooperation: a resilience perspective

  • Jul 11, 2017
  • Production Planning & Control
  • Nachiappan Subramanian +1
  • Conference Article
  • Citations28

Energy aware cloud service provisioning approach for green computing environment

  • Apr 01, 2013
  • T Arthi +1
  • Research Article
  • Citations10

Fast and Accurate Evaluation of Cooling in Data Centers

  • Oct 06, 2014
  • Journal of Electronic Packaging
  • Harshad Bhagwat +4
  • Conference Article

Application Research of Cloud Computing in the Smart Grid Information Processing

  • Jan 01, 2016
  • Di Mou +5
  • Single Report

Electromagnetic Transient Modeling of Large Data Centers for Grid-Level Studies

  • Jan 15, 2026
  • Brett Ross +1
  • PDF
  • Research Article
  • Citations2

A material social view on data center waste heat: Novel uses and metrics

  • Jan 25, 2023
  • Frontiers in Sustainability
  • Petter Terenius +2
  • Book Chapter
  • Citations7

Towards a Non-intrusive Recognition of Anomalous System Behavior in Data Centers

  • Jan 01, 2014
  • Roberto Baldoni +5
  • Research Article
  • Citations2

Using SLA Strategy to Design an SOC Platform in Data Center on the Cloud Computing

  • Sep 01, 2013
  • Journal of Internet Technology
  • Shin-Jer Yang
  • Conference Article
  • Citations19

3D ROC Analysis for Medical Imaging Diagnosis

  • Jan 01, 2005
  • Su Wang +7
  • Conference Article
  • Citations6

IM session identification by outlier detection in cross-correlation functions

  • Mar 01, 2015
  • Saad Saleh +4
  • Conference Article
  • Citations6

Data Center Cooling System Integrated with Low-Temperature Desalination and Intelligent Energy-Aware Control

  • Oct 01, 2018
  • Sanjeev Sondur +2
  • Conference Article
  • Citations10

Reduce VM migration in bandwidth oversubscribed cloud data centres

  • Apr 01, 2015
  • Khyyam Shahzad +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.