Abstract

I describe and demonstrate a rapid and simple technique for calibrating spherical reference surfaces in Fizeau interferometry. A flat mirror at the focus of the test wavefront and a partial occlusion of the test beam enable a double-pass measurement of one half of the surface against the other, which gives an error map for half the aperture. Subsequent rotations of the beam stop and stitching together of several measurements yields the full-aperture calibration file. The method always produces point-symmetrical surface maps and is therefore not exact. However, most actual reference surfaces are approximately point symmetric and therefore the trade-off of accuracy for expediency is reasonable in practice.

Similar Papers
  • Conference Article
  • Citations2

Self-referencing calibration method for transmission spheres in Fizeau interferometry

  • Aug 01, 2010
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Jan Burke +1
  • Research Article
  • Citations30

Calibration of computer-assisted (Respicomp) respiratory inductive plethysmography in newborns.

  • Apr 01, 1985
  • American Review of Respiratory Disease
  • Robert Hughes Warren +1
  • Conference Article

Accurately measuring a surface by using a computer-generated hologram

  • Aug 10, 2008
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Hua Liu +2
  • Conference Article
  • Citations6

Freeform testability considerations for subaperture stitching interferometry

  • Nov 15, 2019
  • Paul E Murphy +1
  • PDF
  • Research Article
  • Citations21

Analysis and comparison of monofocal, extended depth of focus and trifocal intraocular lens profiles

  • May 23, 2022
  • Scientific Reports
  • Juan J Miret +4
  • Research Article
  • Citations6

Measurement of the surface form error of a spherical surface with a wedge phase shifting Fizeau interferometer

  • Apr 23, 2013
  • Journal of Optics
  • Sanjib Chatterjee +1
  • Research Article
  • Citations7

Ion Beam Figuring System for Ultra-Precise Optics

  • Jun 14, 2012
  • Key Engineering Materials
  • Zheng Yuan +3
  • PDF
  • Research Article
  • Citations6

Station Aridity in Weather Monitoring Networks: Evidence from the Oklahoma Mesonet

  • Jan 01, 2023
  • Applied Engineering in Agriculture
  • Aseem Singh +3
  • Conference Article
  • Citations1

Propagation error in precision Fizeau interferometry

  • Jan 01, 1992
  • Chunsheng Huang
  • Research Article
  • Citations16

The times and amplitudes of core phases for a variable core-mantle boundary layer

  • Feb 01, 1992
  • Geophysical Journal International
  • T Rekdal +1
  • Research Article
  • Citations64

Focusing of partially coherent light in systems of large Fresnel numbers

  • Feb 01, 1997
  • Journal of the Optical Society of America A
  • Weijian Wang +2
  • Conference Article
  • Citations15

Absolute Measurement of Rotationally Symmetric Aspheric Surfaces

  • Jan 01, 2006
  • Frontiers in Optics
  • Michael Kuechel
  • Research Article
  • Citations110

Rapid Calibration of Operational and Research Meteorological Satellite Imagers. Part I: Evaluation of Research Satellite Visible Channels as References

  • Sep 01, 2002
  • Journal of Atmospheric and Oceanic Technology
  • Patrick Minnis +5
  • Conference Article
  • Citations2

Estimation of area at risk in myocardial infarction

  • Sep 01, 2007
  • J Carnicky +7
  • Conference Article
  • Citations1

A lightweight mirror made of a magnesium alloy for space-borne telescopes and instruments

  • Jun 06, 2018
  • Keigo Enya +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.