Abstract

Automated external defibrillators (AEDs) play a key role in the community resuscitation of persons with cardiac arrest and are of proven clinical benefit. Although AEDs are complex medical devices designed to function during life-threatening emergencies, little is known about their reliability. To determine the number and rate of AED recalls and safety alerts, to identify trends in these rates, and to identify the types of malfunctions prompting AED and AED accessory advisories. Analysis of weekly US Food and Drug Administration (FDA) Enforcement Reports between January 1996 and December 2005 was performed to identify all recalls and safety alerts (collectively referred to as "advisories") involving AEDs and AED accessories. Confirmed AED device malfunctions were identified by reviewing AED-related adverse events reported to the FDA. Number of AEDs and AED accessories subject to FDA recall or safety alert between January 1996 and December 2005; annual AED advisory rates; and number of confirmed fatal AED-related device malfunctions reported to the FDA. During 2.78 million AED device-years of observation, 52 advisories (median [25th and 75th percentiles], 4.5 [3.0 and 5.0] per year) affecting 385,922 AEDs and AED accessories were issued. The mean (SE) annual number of AEDs affected by advisories was 5.1 (1.5) devices per 100 AED device-years. Overall, 21.2% of AEDs distributed during the study period were recalled, most often because of electrical or software problems. The AED advisory rate did not significantly increase during the study period, although the annual number of AED advisories (P for trend =.02) and AED advisory devices (P for trend = .01) did increase. Confirmed fatal AED-related device malfunctions occurred in 370 patients. Automated external defibrillators and AED accessory advisories occur frequently and affect many devices. Actual AED malfunctions do occur occasionally, although the number of observed malfunctions is small compared with the number of lives saved by these important devices. As the prevalence of AEDs continues to increase, the number of devices affected by advisories can also be expected to increase. Efforts should be directed at developing a reliable system to locate and repair potentially defective devices in a timely fashion.

Similar Papers
  • Research Article
  • Citations1

Strategic Mapping and Optimised Allocation of Automated External Defibrillators in Urban Areas

  • Nov 15, 2020
  • International Journal of Scientific Research in Computer Science, Engineering and Information Technology
  • Kanteler Despoina +2
  • Research Article
  • Citations125

Survival after Public Access Defibrillation in Stockholm, Sweden – A striking success

  • Mar 12, 2015
  • Resuscitation
  • Mattias Ringh +8
  • Research Article
  • Citations1

Discussion on automated external defibrillator configuration optimization strategy of rapidly developing city: a case study of Bao'an, Shenzhen

  • Jan 01, 2022
  • Zhonghua wei zhong bing ji jiu yi xue
  • Jian Wei +3
  • Research Article
  • Citations324

Part 6: Electrical Therapies

  • Oct 17, 2010
  • Circulation
  • Mark S Link +9
  • Research Article

Analysis and Optimization of Automated External Defibrillator (AED) Configuration in Chinese Cities: A Case Study of Dongcheng District, Beijing

  • Oct 12, 2025
  • Risk Management and Healthcare Policy
  • Yunke Shi +1
  • Research Article
  • Citations3

Simulation of the Effects of Co-Locating Naloxone with Automated External Defibrillators

  • Mar 01, 2018
  • Prehospital Emergency Care
  • Jessica E Salerno +2
  • Abstract

27 Implementation, temporal changes, and follow-up of a nationwide AED-network

  • May 01, 2017
  • BMJ Open
  • Lim Karlsson +10
  • Research Article

Abstract 233: Characterizing Impact of State Legislation on Cardiac Arrest Outcomes at K-12 Schools

  • Nov 17, 2020
  • Circulation
  • Edward Ford +5
  • Research Article

Improved survival with AED-only training in a public-access defibrillation program: a 23-year database analysis of project Vita

  • Nov 05, 2025
  • European Heart Journal
  • D Aschieri +8
  • Research Article
  • Citations31

Attitudes toward automated external defibrillator use in Japan

  • Jul 17, 2008
  • Resuscitation
  • Takumi Taniguchi +2
  • Research Article
  • Citations43

AED use in businesses, public facilities and homes by minimally trained first responders

  • Oct 15, 2003
  • Resuscitation
  • Dawn B Jorgenson +4
  • Research Article
  • Citations1

Abstract 121: The Influence of Age, Race, and Ethnicity on Public Automated External Defibrillator Use and Outcomes of Pediatric Out-of-Hospital Cardiac Arrest in the United States: An Analysis of the Cardiac Arrest Registry to Enhance Survival (CARES)

  • Nov 06, 2018
  • Circulation
  • Heather Griffis +9
  • Research Article

Bystanders’ attitudes towards drone delivered Automated External Defibrillators for out-of-hospital cardiac arrest: A qualitative interview study

  • Dec 03, 2025
  • PLOS One
  • Celia J Bernstein +7
  • Research Article
  • Citations256

Impact of Onsite or Dispatched Automated External Defibrillator Use on Survival After Out-of-Hospital Cardiac Arrest

  • Oct 17, 2011
  • Circulation
  • Jocelyn Berdowski +5
  • Abstract

AP-452680-2 GEOSPATIAL ANALYSIS OF BYSTANDER-INITIATED AUTOMATED EXTERNAL DEFIBRILLATOR UTILIZATION IN A LARGE US COMMUNITY

  • May 01, 2023
  • Heart Rhythm
  • Habiba Aziz +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.