• Home
  • Search
  • Reduced RF power without blurring: correcting for modulation of refocusing flip angle in FSE sequences.
  • Cite Icon65
  • https://doi.org/10.1002/mrm.20056Copy DOI Icon

Reduced RF power without blurring: correcting for modulation of refocusing flip angle in FSE sequences.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

In order to reduce the RF power deposition of fast spin echo sequences operated at high field strength, the flip angles of the refocusing pulse train are varied from pulse to pulse using a modulated angle refocusing train method. The technique employs high flip angle pulses prior to sampling the center of k-space in order to preserve T(2) contrast, low flip angles after sampling the center of k-space to reduce power and prolong relaxation, and a smooth transition between the high and low flip angle regimes in order to maintain the pseudosteady-state, maximizing signal and avoiding artifact-inducing oscillations. An analytical expression is used to predict and correct for the flip angle dependence of the signal, thus eliminating any deleterious effects of flip angle modulation on the point spread function. Analysis of resolution and SNR were performed in simulation and phantom studies. In human imaging studies, it is shown that RF energy deposition per slice in a single-shot fast spin echo application can be reduced by up to 75%, making the sequence as practical at 3 T as it is has been at 1.5 T.

Similar Papers
  • Research Article
  • Citations57

Liver MRI in the hepatocyte phase with gadolinium‐EOB‐DTPA: Does increasing the flip angle improve conspicuity and detection rate of hypointense lesions?

  • Oct 27, 2011
  • Journal of Magnetic Resonance Imaging
  • Mustafa R Bashir +5
  • Research Article
  • Citations19

Hypointense hepatocellular nodules on hepatobiliary phase of Gd‐EOB‐DTPA‐enhanced MRI: Can increasing the flip angle improve conspicuity of lesions?

  • Nov 12, 2012
  • Journal of Magnetic Resonance Imaging
  • Tsutomu Tamada +8
  • Research Article
  • Citations19

Evaluation of the inner ear by 3D fast asymmetric spin echo (FASE) MR imaging: phantom and volunteer studies

  • Jan 20, 1999
  • Magnetic Resonance Imaging
  • Dewen Yang +3
  • Research Article
  • Citations20

Accuracy, precision, and reproducibility of myocardial T1 mapping: A comparison of four T1 estimation algorithms for modified look-locker inversion recovery (MOLLI).

  • Dec 04, 2016
  • Magnetic Resonance in Medicine
  • Jiaxin Shao +4
  • Dissertation

Tools for quantitative MR imaging and spectroscopy for the improvement of therapy evaluation in oncology

  • Jul 01, 2020
  • Quincy Van Houtum
  • Research Article
  • Citations1

Hidden Pitfall in Multiple Sclerosis Imaging: How Standard Susceptibility-Weighted Imaging (SWI) May Miss Paramagnetic Rim Lesions

  • Aug 09, 2025
  • Magnetic Resonance in Medical Sciences
  • Yuki Sonoda +12
  • Research Article
  • Citations1

Neuromelanin Contrast Optimization and Improved Visualization of the Substantia Nigra in a 3D Gradient‐Echo Sequence With Magnetization Transfer

  • Aug 19, 2025
  • Nmr in Biomedicine
  • Begoña Garate Andikoetxea +6
  • Research Article
  • Citations11

The influence of flip angle on the magic angle effect.

  • Oct 30, 2000
  • Skeletal Radiology
  • John V Zurlo +2
  • Research Article
  • Citations24

Non-breath-hold fast spin-echo versus breath-hold fast spin-echo and spoiled gradient-recalled echo MR imaging in the detection of hepatic tumors: correlation with surgical findings.

  • May 01, 1997
  • AJR. American journal of roentgenology
  • P Soyer +5
  • Research Article
  • Citations3

Exploring the need for a preload on the estimation of permeability, vessel radius, and relative cerebral blood volume in MR vascular fingerprinting-based dynamic susceptibility contrast perfusion imaging.

  • Nov 28, 2024
  • Magnetic resonance in medicine
  • Daniëlle Van Dorth +7
  • Research Article
  • Citations110

Accuracy, repeatability, and interplatform reproducibility of T1 quantification methods used for DCE-MRI: Results from a multicenter phantom study.

  • Sep 14, 2017
  • Magnetic Resonance in Medicine
  • Octavia Bane +22
  • Research Article
  • Citations4

Structural imaging of the cervical spinal cord with suppressed CSF signal using DANTE pulse trains.

  • Sep 25, 2014
  • Magnetic resonance in medicine
  • Linqing Li +5
  • Research Article
  • Citations12

T2-weighted MRI for the assessment of joint effusion: comparative study of conventional spin-echo and fast spin-echo sequences

  • Jun 01, 2004
  • Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology
  • Shintaro Mori +5
  • Research Article
  • Citations276

The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI.

  • Nov 01, 1992
  • Magnetic Resonance in Medicine
  • R.Todd Constable +1
  • Research Article
  • Citations13

The effects of equilibrium transcytolemmal water exchange on the determination of contrast reagent concentration in vivo

  • Jan 23, 2002
  • Magnetic Resonance in Medicine
  • Charles S Springer +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.