Abstract

Single sensor passive millimetre wave (PMMW) imaging systems typically suffer from long acquisition times, which inhibit their utilization in some security applications (i.e. concealed weapons detection systems) where real time operation is required. This is inherent to the physical principle behind the system, where the achievable temperature resolution and the integration time are inversely proportional to each other. The longer the sensor can collect (and integrate) energy radiated by the scene at each position, the finer the temperature resolution becomes. Reducing the integration time without degrading the temperature resolution can be achieved by increasing the bandwidth of the radiometer, but this is possible only up to certain limits. We propose to reduce the acquisition time in such a single sensor, by combining the recent theory of compressive sensing with special sparse trajectories, designed to achieve the level of incoherence that the theory of compressive sensing requires to successfully recover the image. Another alternative proposal is to sample all the pixels in the scene, but for each pixel, the integration time is randomly selected from a pool of discrete possible values. The radiometric image is then reconstructed by combining the images obtained from the individual application of compressive sensing to each group of pixels having the same integration time. For demonstration purposes, a single pixel PMMW imaging simulator has been implemented in Matlab/Simulink, which includes a configurable radiometric scene generator. The paper presents results from simulated radiometric scenes at 140GHz acquired with the proposed sparse trajectories and recovered using compressive sensing. The results show that savings in acquisition times between 50% and 70% are possible while maintaining the required temperature resolution.

Similar Papers
  • Conference Article

Research on Scale-Changing Targets Detection Algorithm Using Features Fusion in Passive Millimeter Wave Imaging

  • Dec 07, 2013
  • Dekuan Li +4
  • Research Article
  • Citations1

Design of Ka-band Linear Tapered Slot Antennas Based on Substrate Integrated Waveguide Feed

  • Mar 19, 2020
  • 电子与信息学报
  • Honggang Hao +3
  • Conference Article

Research on Compressive Super-Resolution Algorithm Based on Pre-classification Learning for Passive Millimeter Wave Images

  • Dec 07, 2013
  • Zhuli Cao +3
  • Conference Article
  • Citations22

Evaluation of a passive millimeter-wave (PMMW) imager for wire detection in degraded visual conditions

  • May 01, 2009
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Roger Appleby +2
  • Research Article

English

  • May 23, 2007
  • Defence Science Journal
  • Debasis Chaudhuri +2
  • Conference Article
  • Citations1

Multi-channel millimeter wave image registration and segmentation for concealed object detection

  • Apr 23, 2010
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Dong-Su Lee +3
  • PDF
  • Research Article
  • Citations3

A Novel Otsu Method Based on Prior Area Information for Concealed Target Detection in PMMW Images

  • Jan 01, 2016
  • MATEC Web of Conferences
  • Jintao Xiong +5
  • Conference Article
  • Citations1

A New Method for Passive Millimeter Wave Image Registration by Applying Super Resolution

  • Aug 01, 2011
  • Quanliang Huang +2
  • Conference Article
  • Citations5

Image segmentation of concealed objects detected by passive millimeter wave imaging

  • Sep 01, 2009
  • Dong-Su Lee +3
  • PDF
  • Research Article
  • Citations1

A Novel Image Fusion Algorithm for Visible and PMMW Images based on Clustering and NSCT

  • Jan 01, 2016
  • MATEC Web of Conferences
  • Jintao Xiong +5
  • Conference Article
  • Citations2

Development of passive millimeter-wave imaging systems and its applications to medical- and bio-objects imaging

  • Sep 08, 2004
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Minkyoo Joung +7
  • Conference Article
  • Citations3

Characterisation and calibration of a large aperture (1.6 m) ka-band indoor passive millimetre wave security screening imager

  • Oct 26, 2012
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Neil A Salmon +2
  • Conference Article
  • Citations3

<title>Passive millimeter-wave video camera for aviation applications</title>

  • Jul 30, 1998
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Steven W Fornaca +2
  • Research Article
  • Citations5

PASSIVE MILLIMETER WAVE IMAGE DENOISING BASED ON ADAPTIVE MANIFOLDS

  • Jan 01, 2014
  • Progress In Electromagnetics Research B
  • Shujin Zhu +3
  • Conference Article
  • Citations6

Passive millimeter wave imaging sensor enhanced vision system

  • Oct 26, 1997
  • A Ortiz
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.