• Home
  • Search
  • Reference Database for a Novel Binocular Visual Function Perimeter: A Randomized Clinical Trial
  • Cite Icon2
  • https://doi.org/10.1016/j.xops.2024.100583Copy DOI Icon

Reference Database for a Novel Binocular Visual Function Perimeter: A Randomized Clinical Trial

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

PurposeTo construct a comprehensive reference database for a novel binocular automated perimeter. DesignA four-site prospective randomized clinical trial. Subjects and controls356 healthy subjects without ocular conditions that might affect visual function were categorized into 7 age groups. MethodsSubjects underwent comprehensive ocular examination of both eyes before enrollment. Using the TEMPO/IMOvifa automated perimeter (Topcon Healthcare/CREWT Medical Systems, Tokyo, Japan), each subject completed four binocular threshold visual field (VF) tests during a single visit: First, practice 24-2 and 10-2 tests were obtained from both eyes. Next, study 24-2 and 10-2 tests were obtained from both eyes. Test order of each sequence was randomized, and the tests were conducted under Standard Automated Perimetry testing conditions (SAP): Goldmann stimulus size III, 3183 cd/m2 maximum stimulus intensity, and background intensity of 10 cd/m2, using AIZE-Rapid test strategy. Standard VF reliability indices were assessed. For each subject, 24-2 and 10-2 test results from one randomly selected eye were analyzed. Main Outcome MeasuresPerimetric threshold sensitivity and reference limits for each test analysis parameter. ResultsThe ages of the study cohort were widely distributed, with a mean age (SD) of 52.3 (18.5) years. Sex assignment was 44.0% male and 56.0% female. The majority of subjects self-identified as White (67.4%), followed by Black or African American (13.5%) and Asian (8.7%), with 14.6% self-identified as Hispanic or Latino ethnicity. Mean sensitivity (MS) (SD) was 29.1 (1.3) decibels (dB) for the 24-2 and 32.4 (1.0) dB for the 10-2 test. For the 24-2 and 10-2, MS (SD) age-related changes averaged -0.06 (0.01) dB and -0.05 (0.01) dB per year, respectively. The normal range of pointwise threshold sensitivity increased with eccentricity and showed asymmetry around the mean, particularly notable in the 24-2 test. Mean (SD) binocular test duration was 3.18 (0.38) minutes (1 minute 35 seconds per eye) for the 24-2 test and 3.58 (0.43) minutes (1minute 47 seconds per eye) for the 10-2 test. ConclusionsA reference database for the TEMPO/IMOvifa perimeter was established, highlighting the significance of considering both age and stimulus eccentricity in interpreting threshold visual field test results.

Similar Papers
  • Research Article
  • Citations16

Menstrual cycle dependent changes in blue-on-yellow visual field analysis of young diabetic women with severe non-proliferative diabetic retinopathy.

  • Jun 01, 2004
  • Clinical & experimental ophthalmology
  • K Cemil Apaydin +4
  • Research Article
  • Citations3

The determinants of motorized mobility scooter driving ability after a stroke

  • Apr 16, 2020
  • Disability and Rehabilitation
  • Fang-Ling Ku +5
  • Research Article

Clinical observation of optical coherence tomography and visual field in central serous chorioretinopathy

  • Jan 10, 2014
  • Chinese Journal of Practical Ophthalmology
  • Kaizhuan Yang +2
  • Discussion
  • Citations1

Commentary: Rethinking 10-2 visual fields in early diagnosis of glaucoma for a glided glaucoma practice: The right choice to pick up a feeble noise?

  • Mar 01, 2023
  • Indian Journal of Ophthalmology
  • Prasanna V Ramesh +3
  • Research Article
  • Citations10

Comparison of rates of change between binocular and monocular visual fields.

  • Jan 06, 2015
  • Investigative Ophthalmology & Visual Science
  • Y S Chun +2
  • Research Article
  • Citations19

Patterns of Binocular Visual Field Loss Derived from Large-Scale Patient Data from Glaucoma Clinics

  • Sep 29, 2015
  • Ophthalmology
  • Sen Hu +3
  • Research Article
  • Citations50

The learning effect in visual field testing of healthy subjects using frequency doubling technology.

  • Dec 01, 2002
  • Journal of Glaucoma
  • Amjad Horani +5
  • Research Article
  • Citations3

A Novel Approach to Measuring Binocular Visual Fields in Glaucoma.

  • Apr 02, 2021
  • Journal of Glaucoma
  • Neetha I.R Kuzhuppilly +4
  • Research Article
  • Citations7

Usefulness of frequency doubling technology perimetry 24-2 in glaucoma with parafoveal scotoma

  • Jun 01, 2017
  • Medicine
  • Kyoung In Jung +2
  • Research Article

Visual field analysis after laser in situ keratomileusis

  • Jan 25, 2008
  • Chinese Journal of Optometry & Ophthalmology
  • 刘磊 +2
  • Research Article
  • Citations3

Confrontation Visual Field Loss as a Function of Decibel Sensitivity Loss on Automated Static Perimetry. Implications on the Accuracy of Confrontation Visual Field Testing

  • Mar 01, 1996
  • Journal of Neuro-Ophthalmology
  • S Shahinfar +2
  • Research Article
  • Citations2

Binocular Visual Field and Vision-Related Quality of Life in Patients With Hemianopia.

  • Apr 26, 2021
  • Journal of Neuro-Ophthalmology
  • Barbara Burgos-Blasco +6
  • Research Article
  • Citations14

Elevation of Intraocular Pressure in Glaucoma Patients After Automated Visual Field Testing

  • Dec 01, 2012
  • Journal of Glaucoma
  • Nina Ni +3
  • Research Article
  • Citations23

Assessment of an Effective Visual Field Testing Strategy for a Normal Pediatric Population

  • Jul 12, 2008
  • Ophthalmologica
  • Yusuf Akar +2
  • Research Article
  • Citations198

Assessment of the Reliability of Standard Automated Perimetry in Regions of Glaucomatous Damage

  • Mar 12, 2014
  • Ophthalmology
  • Stuart K Gardiner +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.