• Home
  • Search
  • Regularized reconstruction in electrical impedance tomography using a variance uniformization constraint.
  • Cite Icon64
  • https://doi.org/10.1109/42.640745Copy DOI Icon

Regularized reconstruction in electrical impedance tomography using a variance uniformization constraint.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

This paper describes a new approach to reconstruction of the conductivity field in electrical impedance tomography. Our goal is to improve the tradeoff between the quality of the images and the numerical complexity of the reconstruction method. In order to reduce the computational load, we adopt a linearized approximation to the forward problem that describes the relationship between the unknown conductivity and the measurements. In this framework, we focus on finding a proper way to cope with the ill-posed nature of the problem, mainly caused by strong attenuation phenomena; this is done by devising regularization techniques well suited to this particular problem. First, we propose a solution which is based on Tikhonov regularization of the problem. Second, we introduce an original regularized reconstruction method in which the regularization matrix is determined by space-uniformization of the variance of the reconstructed condictivities. Both methods are nonsupervised, i.e., all tuning parameters are automatically determined from the measured data. Tests performed on simulated and real data indicate that Tikhonov regularization provides results similar to those obtained with iterative methods, but with a much smaller amount of computations. Regularization using a variance uniformization constraint yields further improvements, particularly in the central region of the unknown object where attenuation is most severe. We anticipate that the variance uniformization approach could be adapted to iterative methods that preserve the nonlinearity of the forward problem. More generally, it appears as a useful tool for solving other severely ill-posed reconstruction problems such as eddy current tomography.

Similar Papers
  • Research Article
  • Citations4

Improvement of performance and sensitivity of 2D and 3D image reconstruction in EIT using EFG forward model

  • Mar 23, 2022
  • Biomedical Physics & Engineering Express
  • M Hadinia +1
  • Research Article
  • Citations49

Incorporating a priori anatomical information into image reconstruction in electrical impedance tomography

  • Jan 01, 1999
  • Physiological Measurement
  • H Dehghani +2
  • Conference Article

On discretization of the depth dimension in electrical impedance tomography problems

  • Mar 01, 2008
  • M Dolgin +1
  • Book Chapter
  • Citations20

Image Reconstruction in Electrical Impedance Tomography (EIT) with Projection Error Propagation-based Regularization (PEPR): A Practical Phantom Study

  • Jan 01, 2012
  • Tushar Kanti Bera +3
  • Research Article
  • Citations9

Impact of the Radial Basis Function Spread Factor onto Image Reconstruction in Electrical Impedance Tomography

  • Jan 01, 2015
  • IFAC-PapersOnLine
  • Marketa Michalikova +2
  • Research Article
  • Citations22

A real-time EIT imaging system based on the split augmented Lagrangian shrinkage algorithm

  • Jun 15, 2017
  • Measurement
  • Yongkang Zhou +1
  • Research Article
  • Citations9

Image reconstruction using simulated annealing in electrical impedance tomography: a new approach

  • Aug 24, 2017
  • Inverse Problems in Science and Engineering
  • J S Martins +2
  • Research Article
  • Citations36

Comparison of statistical inversion with iteratively regularized Gauss Newton method for image reconstruction in electrical impedance tomography

  • May 09, 2019
  • Applied Mathematics and Computation
  • Sanwar Ahmad +3
  • Conference Article

<title>New image reconstruction method in dynamic electrical impedance tomography</title>

  • Sep 04, 2002
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Weidong Hou +1
  • Research Article
  • Citations35

Electrical Impedance Tomography for Piecewise Constant Domains Using Boundary Element Shape-Based Inverse Solutions

  • May 01, 2007
  • IEEE Transactions on Medical Imaging
  • S Babaeizadeh +1
  • Research Article
  • Citations40

Reconstruction of the shape of conductivity spectra using differential multi-frequency magnetic induction tomography

  • Apr 24, 2006
  • Physiological Measurement
  • Patricia Brunner +5
  • Research Article
  • Citations2

Simultaneous Acquisition of EIT and ECG Signals on Active EIT Electrodes.

  • Apr 01, 2025
  • IEEE transactions on bio-medical engineering
  • Ahmed Abdelwahab +7
  • Research Article
  • Citations65

A novel deep neural network method for electrical impedance tomography

  • May 03, 2019
  • Transactions of the Institute of Measurement and Control
  • Xiuyan Li +8
  • Research Article
  • Citations94

Sparsity reconstruction in electrical impedance tomography: An experimental evaluation

  • Oct 03, 2011
  • Journal of Computational and Applied Mathematics
  • Matthias Gehre +6
  • Research Article
  • Citations1

OOEIT: An open source object oriented electrical impedance tomography software package

  • Jan 01, 2024
  • Applied Mathematics for Modern Challenges
  • Petri Kuusela +1
Cactus Communications logo