• Home
  • Search
  • Resolution evaluation of MR images reconstructed by iterative thresholding algorithms for compressed sensing
  • Cite Icon26
  • https://doi.org/10.1118/1.4728223Copy DOI Icon

Resolution evaluation of MR images reconstructed by iterative thresholding algorithms for compressed sensing

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Magnetic resonance imaging systems usually feature linear and shift-invariant (stationary) transform characteristics. The point spread function or equivalently the modulation transfer function may thus be used for an objective quality assessment of imaging modalities. The recently introduced theory of compressed sensing, however, incorporates nonlinear and nonstationary reconstruction algorithms into the magnetic resonance imaging process which prohibits the usage of the classical point spread function and therefore the according evaluation. In this work, a local point spread function concept was applied to assess the quality of magnetic resonance images which were reconstructed by an iterative soft thresholding algorithm for compressed sensing. The width of the main lobe of the local point spread function was used to perform studies on the spatial and temporal resolution properties of both numerical phantom and in vivo images. The impact of k-space sampling patterns as well as additional sparsifying transforms on the local spatial image resolution was investigated. In addition, the local temporal resolution of image series, which were reconstructed by exploiting spatiotemporal sparsity, was determined. Finally, the dependency of the local resolution on the thresholding parameter of the algorithm was examined. The sampling patterns as well as the additional sparsifying transform showed a distinct impact on the local image resolution of the phantom image. The reconstructions, which were using x-f-space as a sparse transform domain showed slight temporal blurring for dynamic parts of the imaged object. The local image resolution had a dependence on the thresholding parameter, which allowed for optimizing the reconstruction. Local point spread functions enable the evaluation of the local spatial and temporal resolution of images reconstructed with the nonlinear and nonstationary iterative soft thresholding algorithm. By determining the influence of thresholding parameter and sampling pattern chosen on this model-based reconstruction, the method allows selecting appropriate acquisition parameters and thus improving the results.

Similar Papers
  • Research Article
  • Citations13

A new linear convergence result for the iterative soft thresholding algorithm

  • Apr 17, 2017
  • Optimization
  • Lufang Zhang +3
  • Conference Article
  • Citations4

Accelerated methods for low-rank plus sparse image reconstruction

  • Apr 01, 2018
  • Claire Yilin Lin +1
  • Research Article
  • Citations43

Efficient Dynamic Parallel MRI Reconstruction for the Low-Rank Plus Sparse Model.

  • Nov 19, 2018
  • IEEE transactions on computational imaging
  • Claire Yilin Lin +1
  • Research Article
  • Citations5

Effectiveness of Safe Working Procedure on SMF Exposure Levels and Work Performances in 3 T MRI System Operations

  • Nov 01, 2015
  • IEEE Transactions on Magnetics
  • S Yamaguchi-Sekino +2
  • Research Article
  • Citations55

Use of 3.0-T MR Imaging for Evaluation of the Abdomen

  • Oct 01, 2009
  • RadioGraphics
  • Sukru Mehmet Erturk +4
  • Research Article
  • Citations1

L1- and F-norm joint edge preservation optimization algorithm for complex image sparse SAR reconstruction imaging model

  • Feb 07, 2025
  • International Journal of Remote Sensing
  • Fengyun Wang +5
  • Conference Article
  • Citations2

Fast Decoding and Parameters Selection for CS-JPEG Video Codec

  • Oct 06, 2021
  • Evgeny Belyaev
  • PDF
  • Research Article
  • Citations7

A novel Fourier-based deconvolution algorithm with improved efficiency and convergence

  • Sep 12, 2019
  • Journal of Low Frequency Noise, Vibration and Active Control
  • Linbang Shen +3
  • Research Article
  • Citations22

MR-compatibility assessment of MADPET4: a study of interferences between an SiPM-based PET insert and a 7 T MRI system

  • Apr 30, 2018
  • Physics in Medicine & Biology
  • Negar Omidvari +5
  • Research Article
  • Citations1

Fast analytical calculation method for eddy current induced by gradient fields in an MRI system

  • Nov 06, 2017
  • COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
  • Zheng Xu +5
  • Research Article
  • Citations19

Non-parametric Sub-pixel Local Point Spread Function Estimation

  • Mar 23, 2012
  • Image Processing On Line
  • Mauricio Delbracio +2
  • Conference Article
  • Citations5

A feasibility study for MRI guided CMUT-based intracardiac echocardiography catheters

  • Sep 01, 2017
  • Seyedabdollah Mirbozorgi +6
  • Conference Article
  • Citations1

Blind restoration of retinal images degraded by space-variant blur with adaptive blur estimation

  • Nov 18, 2013
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Andrés G Marrugo +3
  • Research Article
  • Citations10

Section thickness and contiguity phantom for MR imaging.

  • Jul 01, 1987
  • Radiology
  • J E Gray +1
  • Book Chapter
  • Citations3

Image-Based Detection of MRI Hardware Failures

  • Jan 01, 2019
  • Bhavya Jain +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.