- Research Article
18
- 10.1016/j.sigpro.2010.06.017
Watermarking in halftone images with parity-matched error diffusion
- Jun 23, 2010
- Signal Processing
- Jing-Ming Guo + 2 more +2
Watermarking in halftone images with parity-matched error diffusion
A halftone watermarking method of high quality, robustness, and capacity flexibility is presented in this paper. An objective halftone image quality evaluation method based on the human visual system obtained by least-mean-square is also introduced. In the encoder, the kernels-alternated error diffusion (KAEDF) is applied. This is able to maintain the computational complexity at the same level as ordinary error diffusion. Compared with Hel-Or (2001) using ordered dithering, the proposed KAEDF yields a better image quality through using error diffusion. We also propose a weighted lookup table (WLUT) in the decoder instead of LUT, as proposed by Pei and Guo (2003), so as to achieve a higher decoded rate. As the experimental results demonstrated, this technique is able to guard against degradation due to tampering, cropping, rotation, as well as print-and-scan processes in error-diffused halftone images.
Watermarking in halftone images with parity-matched error diffusion
Watermarking in halftone images with parity-matched error diffusion
Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction.
Many technical updates have been made in multi-detector CT. To evaluate image quality and radiation dose of high-pitch second- and third-generation dual-source chest CT angiography and to assess the effects of different levels of advanced modeled iterative reconstruction (ADMIRE) in newborns and children. Chest CT angiography (70 kVp) was performed in 42 children (age 158 ± 267 days, range 1-1,194 days). We evaluated subjective and objective image quality, and radiation dose with filtered back projection (FBP) and different strength levels of ADMIRE. For comparison were 42 matched controls examined with a second-generation 128-slice dual-source CT-scanner (80 kVp). ADMIRE demonstrated improved objective and subjective image quality (P < .01). Mean signal/noise, contrast/noise and subjective image quality were 11.9, 10.0 and 1.9, respectively, for the 80 kVp mode and 11.2, 10.0 and 1.9 for the 70 kVp mode. With ADMIRE, the corresponding values for the 70 kVp mode were 13.7, 12.1 and 1.4 at strength level 2 and 17.6, 15.6 and 1.2 at strength level 4. Mean CTDIvol, DLP and effective dose were significantly lower with the 70-kVp mode (0.31 mGy, 5.33 mGy*cm, 0.36 mSv) compared to the 80-kVp mode (0.46 mGy, 9.17 mGy*cm, 0.62 mSv; P < .01). The third-generation dual-source CT at 70 kVp provided good objective and subjective image quality at lower radiation exposure. ADMIRE improved objective and subjective image quality.
Read moreHalf-dose abdominal CT with sinogram-affirmed iterative reconstruction technique in children - comparison with full-dose CT with filtered back projection.
Iterative reconstruction can be helpful to reduce radiation dose while maintaining image quality. However, this technique has not been fully evaluated in children during abdominal CT. To compare objective and subjective image quality between half-dose images reconstructed with iterative reconstruction at iteration strength levels 1 to 5 (half-S1 to half-S5 studies) and full-dose images reconstructed with filtered back projection (full studies) in pediatric abdominal CT. Twenty-one children (M:F = 13:8; mean age 8.2 ± 5.7years) underwent dual-source abdominal CT (mean effective dose 4.8 ± 2.1mSv). The objective image quality was evaluated as noise. Subjective image quality analysis was performed comparing each half study to the full study for noise, sharpness, artifact and diagnostic acceptability. Both objective and subjective image noise decreased with increasing iteration strength. Half-S4 and -S5 studies showed objective image noise similar to or lower than that of full studies. The half-S2 and -S3 studies produced the greatest sharpness and the half-S5 studies were the worst from a blocky appearance. Full and half studies did not differ in artifacts. Half-S3 studies showed the best diagnostic acceptability. Half-S4 and -S5 studies objectively and half-S3 studies subjectively showed comparable image quality to full studies in pediatric abdominal CT.
Read moreEvaluating a low-dose protocol for computed tomography (CT) pulmonary angiography: combining reduced contrast medium, low tube voltage, and advanced image reconstruction.
Evaluating a low-dose protocol for computed tomography (CT) pulmonary angiography: combining reduced contrast medium, low tube voltage, and advanced image reconstruction.
Read moreQuantitative and qualitative analysis of knee magnetic resonance imaging using low- and high-field strength units.
Quantitative and qualitative analysis of knee magnetic resonance imaging using low- and high-field strength units.
Low-dose ultra-high-pitch computed tomography coronary angiography: identifying the optimum combination of iteration strength and radiation dose reduction strategies to achieve true submillisievert scans
To identify the optimum strength of advanced modeled iterative reconstruction (ADMIRE) to achieve the best subjective and objective image quality when combining three-dose reduction strategies, ultra-high-pitch computed tomography coronary angiography (FLASH CTCA; with single-dose ivabradine to lower heart rate), low tube voltage, and ADMIRE. Sixty consecutive patients underwent FLASH CTCA at 100 kVp in this single-center prospective study. Single-dose ivabradine was administered to patients whose heart rate was above 75 bpm. Images were reconstructed using the three highest strengths of ADMIRE (A3, A4, and A5). Objective and subjective image quality (using a Likert scale) were evaluated in the three datasets. The signal strength remained unchanged but mean noise significantly reduced across the increasing strengths of ADMIRE [signal: 513.78 ± 101.7 Hounsfield units (HU) at A3, 515.6 ± 100.5 HU at A4, and 519.7 ± 107.9 HU at A5; noise: 23.4 ± 4.5 HU at A3, 20.2 ± 3.6 HU at A4, and 17.2 ± 3.3 HU at A5]. Signal-to-noise and contrast-to-noise ratios were the highest at A5, and A5 offered significantly higher Likert scores in image noise, vessel sharpness, and overall image quality than A3 or A4. Additionally, A5 did not interfere with image interpretation in any patient. Using all three dose reduction strategies during FLASH CTCA along with single-dose ivabradine administration ensures minimal radiation exposure in daily practice. In this study, A5 datasets had the best overall subjective and objective image quality despite their "plastic appearance". In the future, enhanced dose reduction can be obtained by further lowering tube voltages.
Read moreDetection and Diagnosis of Glaucoma: Ocular Imaging
Imaging is a valuable tool in the assessment of glaucoma and glaucoma progression. Although glaucoma is a clinical diagnosis—there is no blood test or definitive genetic test, for example, for the disease—the diagnosis has traditionally been subjective albeit based on certain physical characteristics of the patient. Over the years, the diagnosis has gone from a hard, blind, painful eye; to palpation indicating a hard eye associated with sudden pain or slow, painless visual loss; to a specifically described progressive optic neuropathy with characteristic neural damage and visual loss, sometimes associated with elevated intraocular pressure (IOP). In the mid-19th century, Helmholtz and Von Graefe enabled clinical assessment of the optic nerve head (ONH); later, fundus photography permitted objective recording of this physical parameter.1,2 Nevertheless, despite objective photographs of the ONH, subjective interpretation on the part of the clinician was necessary for identification of glaucomatous damage or progression. Different clinicians would provide discrepant interpretations of the optic nerve, and even the same observer would frequently characterize the disc differently on separate viewings of the same photograph.3 Measurement of ocular function is and has been similarly crude and subjective. From discriminating finger movement in different quadrants to discerning white objects on a black background to map the visual field in tangent screen perimetry, the patient must tell the examiner when a light or object is seen. The same is true of kinetic and static perimetry, both manual and automated. The patient must detect the object (or light) on the retina, realize that a light or object has been seen, and then inform the examiner of this fact. The evaluation is difficult as best, often tedious, and fraught with problems in reproducibility of findings. For these reasons, clinicians, scientists, and engineers have sought to objectively measure optic nerve structure and function both quantitatively and reproducibly, preferably without the requirement for patient input. In the assessment of optic nerve function, this has meant multifocal electroretinography,4 pattern electroretinography,5,6 multifocal visual evoked potential, and pattern visual evoked potential,7,8 among other tests.9 Unfortunately, none of these objective functional tests has been validated to the level of perimetry, which remains the clinical gold standard, despite its shortcomings. Automated objective, quantitative characterization of the optic nerve has been more successful. As mentioned above, the first step in this direction was optic nerve photography, particularly stereoscopic disc photography. This method enables objective recording, but still requires subjective interpretation. More sophisticated techniques, invented and/or developed in the past quarter century, include confocal scanning laser ophthalmoscopy (CSLO), scanning laser polarimetry (SLP), and optical coherence tomography (OCT). These systems capture, in different ways, objective, accurate, and precise quantitative information about optic nerve and retinal structure that does not require subjective input for measurement. Although there is objective image and segmentation algorithm quality evaluation, subjective quality assessment is still necessary to ensure that the image acquired is adequate for evaluation and that the analysis algorithm has functioned properly.
Read moreWavelet-based contourlet in quality evaluation of digital images
Wavelet-based contourlet in quality evaluation of digital images
Ultra-fast, low dose high-pitch (FLASH) versus prospectively-gated coronary computed tomography angiography: Comparison of image quality and patient radiation exposure
Ultra-fast, low dose high-pitch (FLASH) versus prospectively-gated coronary computed tomography angiography: Comparison of image quality and patient radiation exposure
Read moreContinuous-tone Watermark Hiding in Halftone Images
In this paper, a low computational complexity method is proposed to embed a multi-tone visual pattern using the concept of secret sharing. One halftone image is obtained using regular error diffusion, and the other image is obtained using the proposed Generalized Noise-Balanced Error Diffusion (GNBEDF) in considering the properties of the watermark and the first halftone image in the same time. With the proposed method, the bi-level watermark embedding becomes a special case to this technology. The bi-level watermark decoding can be simply achieved via printing the two halftone images onto two transparencies and then superimposing them together to reveal the watermark pattern. However, as the multi-tone watermark is involved, the proposed Gaussian Difference (GD) approach is needed to perform the decoding to produce a decoded multi-tone watermark. Throughout this work, a lowpass filter obtained by Least-Mean-Square is employed to assess the image quality.
Read moreInverse color to black-and-white halftone conversion via dictionary learning and color mapping
Inverse color to black-and-white halftone conversion via dictionary learning and color mapping
An Integrated Color Halftone Method for Noise Reduction
Color halftoning is a method for representing continuous tone color images with limited colors. To implement halftone, error diffusion is one of the most popular algorithms due to its highperformance results. In the conventional error diffusion, the fixed thresholds and filter weights are used. In the process, many artifacts are introduced in the halftone images as side effects. With the color aspect, each of the three color planes is independently calculated during the process of traditional error diffusion. However, the pattern of dots formed independently by combining the dots of each of color planes is often not visually pleasing because no effort is made to insure that the dots of each of the different color planes are ideally distributed relative to the dots of the other color planes. In this paper, we present an integrated error diffusion algorithm in which variable filter weights, threshold matrix, serpentine scan path and multi-color halftoning are used to reduce the noises generated during the halftone process. Our experimental results showed that worm-like artifacts, structural artifacts and start-up artifacts are successfully decreased and the color halftoned images are more comfortable to the human visual system.
Read moreImproved Dot Diffusion by Diffused Matrix and Class Matrix Co-Optimization
Dot diffusion is an efficient approach which utilizes concepts of block-wise and parallel-oriented processing to generate halftones. However, the block-wise nature of processing reduces image quality much more significantly as compared to error diffusion. In this work, four types of filters with various sizes are employed in co-optimization procedures with class matrices of size 8 n 8 and 16 x 16 to improve the image quality. The optimal diffused weighting and area are determined through simulations. Many well-known halftoning methods, some of which includes direct binary search (DBS), error diffusion, ordered dithering, and prior dot diffusion methods, are also included for comparisons. Experimental results show that the proposed dot diffusion achieved quality close to some forms of error diffusion, and additionally, superior to the well-known Jarvis and Stucki error diffusion and Mese's dot diffusion. Moreover, the inherent parallel processing advantage of dot diffusion is preserved, allowing us to reap higher executing efficiency than both DBS and error diffusion.
Read moreOptimization of Radiation Exposure and Image Quality of the Cone-beam O-arm Intraoperative Imaging System in Spinal Surgery
Retrospective study. To optimize the radiation doses and image quality for the cone-beam O-arm surgical imaging system in spinal surgery. Neurovascular compromise has been reported after screw misplacement during thoracic pedicle screw insertion. The use of O-arm with or without navigation system during spinal surgery has been shown to lower the rate of screw misplacement. The main drawback of such imaging surgical systems is the high radiation exposure. Chest phantom and cadaveric pig spine were examined on the O-arm with different scan settings: 2 were recommended by the O-arm manufacturer (120 kV/320 mAs, and 120 kV/128 mAs), and 3 low-dose settings (80 kV/80 mAs, 80 kV/40 mAs, and 60 kV/40 mAs). The radiation doses were estimated by Monte Carlo calculations. Objective evaluation of image quality included interobserver agreement in the measurement of pedicular width in chest phantom and assessment of screw placement in cadaveric pig spine. The effective dose/cm for 120 kV/320 mAs scan was 13, 26, and 69 times higher than those delivered with 80 kV/80 mAs, 80 kV/40 mAs, and 60 kV/40 mAs scans, respectively. Images with 60 kV/40 mAs were unreliable. Images with 80 kV/80 mAs were considered reliable with good interobserver agreement when measuring the pedicular width (random error 0.38 mm and intraclass correlation coefficient 0.979) and almost perfect agreement when evaluating the screw placement (κ value 0.86). The radiation doses of the O-arm system can be reduced 5 to 13 times without negative impact on image quality with regard to information required for spinal surgery.
Read moreFully automated image quality evaluation on patient CT: Multi-vendor and multi-reconstruction study.
While the recent advancements of computed tomography (CT) technology have contributed in reducing radiation dose and image noise, an objective evaluation of image quality in patient scans has not yet been established. In this study, we present a patient-specific CT image quality evaluation method that includes fully automated measurements of noise level, structure sharpness, and alteration of structure. This study used the CT images of 120 patients from four different CT scanners reconstructed with three types of algorithm: filtered back projection (FBP), vendor-specific iterative reconstruction (IR), and a vendor-agnostic deep learning model (DLM, ClariCT.AI, ClariPi Inc.). The structure coherence feature (SCF) was used to divide an image into the homogeneous (RH) and structure edge (RS) regions, which in turn were used to localize the regions of interests (ROIs) for subsequent analysis of image quality indices. The noise level was calculated by averaging the standard deviations from five randomly selected ROIs on RH, and the mean SCFs on RS was used to estimate the structure sharpness. The structure alteration was defined by the standard deviation ratio between RS and RH on the subtraction image between FBP and IR or DLM, in which lower structure alterations indicate successful noise reduction without degradation of structure details. The estimated structure sharpness showed a high correlation of 0.793 with manually measured edge slopes. Compared to FBP, IR and DLM showed 34.38% and 51.30% noise reduction, 2.87% and 0.59% lower structure sharpness, and 2.20% and -12.03% structure alteration, respectively, on an average. DLM showed statistically superior performance to IR in all three image quality metrics. This study is expected to contribute to enhance the CT protocol optimization process by allowing a high throughput and quantitative image quality evaluation during the introduction or adjustment of lower-dose CT protocol into routine practice.
Read more