- Research Article
871
- 10.1016/s0006-3495(69)86467-2
Time Constants and Electrotonic Length of Membrane Cylinders and Neurons
- Dec 01, 1969
- Biophysical Journal
- Wilfrid Rall
Time Constants and Electrotonic Length of Membrane Cylinders and Neurons
Sampled-data control of systems with widely varying time constants was investigated via a simple second-order system. The effect of sampling was examined by comparing the gains based on frequency responses of the second-order system and its lower-order model, respectively. It was found that at sampling periods less than the smaller time constant, the gain based on the reduced-order model could lead to instability. Simulation studies were made for the system under the control action of a P-I controller whoso design was based on cither the original system or its reduced-order model. The results suggest that, for eases of set-point changes, the lower-order model is adequate for the purpose of controller design. These controllers should, however, be enforced at a higher sampling rate for better responses. For load disturbances, the simulation results indicated that significant improvements were achieved when the smaller time constant was taken into consideration in the design of the controller.
Time Constants and Electrotonic Length of Membrane Cylinders and Neurons
Time Constants and Electrotonic Length of Membrane Cylinders and Neurons
Nonlinear Modeling of Mechanical Gas Face Seal Systems Using Proper Orthogonal Decomposition
An approach based on proper orthogonal decomposition and Galerkin projection is presented for developing low-order nonlinear models of the gas film pressure within mechanical gas face seals. A technique is developed for determining an optimal set of global basis functions for the pressure field using data measured experimentally or obtained numerically from simulations of the seal motion. The reduced-order gas film models are shown to be computationally efficient compared to full-order models developed using the conventional semidiscretization methods. An example of a coned mechanical gas face seal in a flexibly mounted stator configuration is presented. Axial and tilt modes of stator motion are modeled, and simulation studies are conducted using different initial conditions and force inputs. The reduced-order models are shown to be applicable to seals operating within a wide range of compressibility numbers, and results are provided that demonstrate the global reduced-order model is capable of predicting the nonlinear gas film forces even with large deviations from the equilibrium clearance.
Read morePredictive modelling of boiler fouling. Quarterly technical progress report, April 1, 1992--June 30, 1992
As this study incorporates in a general framework, appropriate modules to model condensable species transport to the surface along with particles, the need for a suitable solver for the reaction component of the species equations with regard to issues of stability, stiffness, economy, etc. becomes obvious. It is generally agreed in the literature that the major problem associated with the simultaneous integration of large sets of chemical kinetic rate equations is that of stiffness. Although stiffness does not have a simple definition, it is characterized by widely varying time constants. For example, in hydrogen-air combustion, the induction time is of the order of microseconds whereas the nitric oxide formation time is of the order of milliseconds. These widely different time constants present classical methods (such as the popular explicit Runge-Kutta method) with the following difficulty: to ensure stability of the numerical solution, these methods are restricted to using very short time steps that are determined by the smallest time constant. However, the time for all chemical species to reach near-equilibrium values is determined by the longest time constant. As a result, classical methods require excessive amounts of computer time to solve stiff systems of ordinary differential equations (ODE`s). Several approaches for the solution of stiff ODE`s have been proposed. Of all these techniques, the general purpose codes EPISODE and LSODE are regarded as the best available ``packaged`` codes for the solution of stiff systems of ODE`S. However, although these codes may be the best available for solving an arbitrary systems ODE`S, it may be possible to construct superior methods for solving a particular system of ODE`s governing the behavior of a specific problem. In this view, an exponentially fitted method, CREK1D, deserves a special mention and is described briefly.
Read moreSystematic reduced order model development of a pitching NACA0012 airfoil
Simple reduced order models (ROMs) for the aerodynamic coefficients - lift, drag, and pitch moment - of a pitching NACA0012 airfoil are presented. The ROMs are designed for quick computation of the transient aerodynamic characteristics of the airfoil and are developed utilizing computational fluid dynamics (CFD) simulation results. The entire aerodynamic system is modeled as a single input, multi output system yielding three independent systems to be characterized. A systematic, two step process is employed to develop the ROMs for each aerodynamic system. First, a CFD simulation is conducted to determine the linearity of each system, and any nonlinear system is restructured as a nonlinear operator followed by a linear system to allow for the use of linear system identification techniques. A second CFD simulation is conducted to determine the frequency response of each linear system, and the coefficients of each ROM are extracted by fitting a second order model to each frequency response function. The ROMs are validated against an independent CFD simulation of a pitching airfoil and are shown to accurately model each aerodynamic coefficient.
Read moreDynamic Performance Characteristics, Part 1
When the input to a sensor is changing rapidly, we observe performance characteristics that are due to the change in input and are not related to static performance characteristics. In this chapter we will assume that a static calibration has been applied so that we can consider dynamic performance independently of static characteristics. The terms “linear” and “nonlinear” have been used in chap. 3 in the static sense. Now they are being used in the dynamic sense where “linear” connotes the applicability of the superposition property. A given sensor could be nonlinear in the static sense (e.g., a PRT is nonlinear in that is static sensitivity is not constant over the range) but could be linear in the dynamic sense (modeled by a linear differential equation). We use differential equations to model this dynamic performance while realizing the models can never be exact. If the dynamic behavior of physical systems can be described by linear differential equations with constant coefficients, the analysis is relatively easy because the solutions are well known. Such equations are always approximations to the actual performance of physical systems that are often nonlinear, vary with time, and have distributed parameters. The justification for the use of simple, readily solved models must be the quality of the fit of the solution to the actual system output and the usefulness of the resulting analysis. Dynamic performance characteristics define the way instruments react to measurand fluctuations. When a temperature sensor is mounted on an airplane these characteristics will indicate what the sensor “sees.” If the airplane flies through a cloud with a slow sensor (where time constant is large) it may not register change of temperature or humidity. That would not be tolerable if we wanted to measure the cloud. Similarly, if the airplane flies through turbulence we would like to measure changes in air speed. Variations in temperature and humidity would be vital in the flight of a radiosonde, so again the time constant of the sensors would be considered. Fluxes of heat, water vapor, and momentum near the ground require fast sensors (with small time constants).
Read moreA systematic study of the dynamics of chain formation in electrorheological fluids
We report a systematic study of the dynamics of chain formation in electrorheological fluids using Brownian dynamics simulations. The parameters of the system such as applied electric field, polarizability, dipole moment, friction coefficient, and number density are expressed in reduced units and changed in a wide range in order to map the system’s behavior as a function of them. We define time constants obtained from bi-exponential fits to time dependence of various physical quantities such as dipolar energy, diffusion constant, and average chain length. The smaller time constant is associated with the formation of shorter chains (pairs, triplets, and so on), while the larger time constant is associated with the formation of longer chains in the regime of those that overarch the simulation cell. We use the approximation that the dipole moments are induced by the applied electric field only, as usual in the literature. However, we report preliminary results for the case when particle–particle polarization is also possible.
Read moreElectrophysiological study of the intestinal smooth muscle of the guinea-pig.
The membrane properties of single cells of intestinal smooth muscle of duodenum, jejunum, ileum, caecum and rectum of guinea-pig have been studied.1. The membrane potentials of longitudinal muscles of the duodenum, jejunum, ileum, caecum and rectum varied from 54 to 56 mV and those of circular muscles of jejunum, ileum, caecum and rectum varied from 57 to 60 mV. The ablated longitudinal muscle had a slightly lower value (50 mV) than the intact one.2. The longitudinal muscle generated spontaneous discharges but these were rare in the circular muscles of the intestine except for the caecum. Overshoot potentials could be observed in all regions of the intestine. The maximum rate of rise of the spontaneously discharging longitudinal muscles varied from 11 to 18 V/sec.3. Not all of the slow potential changes (but at least some) were generated by the nervous elements distributed between the muscle layers and in them.4. The conduction velocities measured from the longitudinal muscles of jejunum and rectum in the presence of tetrodotoxin were 2.1 cm/sec and 4.0 cm/sec respectively.5. Chronaxies of the longitudinal muscles of jejunum and rectum were 2-5 msec and 5-18 msec respectively.6. Intracellular stimulation of the single cells of the duodenum and caecum could trigger a spike, similar to that observed in the taenia coli. The spikes were mostly graded ones; a spike of full size was rarely elicited. When the spikes were triggered, the after-hyperpolarization appeared consistently presumably caused by the increased potassium conductance.7. The effective membrane resistance and the time constant were measured for the longitudinal muscles of the jejunum and rectum. When spikes were generated by intracellular stimulation the observed values were 40-50 MOmega and 3-5 msec in both tissues. These values were the same as those observed in the taenia coli.8. When the time constant of the membrane was measured by the extracellular polarizing method, the longitudinal muscles of the jejunum especially and the rectum had smaller time constants than the taenia coli.9. The differences of conduction velocity and chronaxie of the different regions of the intestine are discussed in relation to the cable properties of the tissues which are directly influenced by the morphological arrangements of the tissues.
Read moreModelling and Control of a nonlinear distillation column: A, using fractional-order controllers
This paper takes up the challenge of modelling a complex nonlinear distillation column type-A and designs four optimal controllers for the same. The nonlinear plant is first linearized into a linear higher-order model. Thereafter, it is reduced into a lower-order model. Subsequently, the controllers are designed for the lower-order linear model. The controllers are designed by reducing the error cost functions, namely Integral Square Error (ISE), Integral Absolute Error (IAE) and Integral Time Absolute Error (ITAE). The process of optimization is done heuristically using the Genetic Algorithm method of tuning. The four controllers designed are Proportional Integral Derivative, Fractional-order Proportional Integral Derivative, Tilt Integral Derivative and Fractional-order Internal Model Control. A thorough comparison is made between the three designed controllers, first on the Single Input Single Output (SISO), then to the reduced-order linear model and finally to the main plant. The FO-IMC controller is shown as an exhibition controller designed using GA to demonstrate the novelty of its kind. It has also been compared, but the results show poor performances as it has not been tuned with the same parameters as the rest.
Read moreApplication of Model Order Reduction to Compressor Aeroelastic Models
A model order reduction technique that yields low-order models of blade row unsteady aerodyamics is introduced. The technique is applied to linearized unsteady Euler CFD solutions in such a way that the resulting blade row models can be linked to their surroundings through their boundary conditions. The technique is applied to a transonic compressor aeroelastic analysis, in which the high-fidelity CFD forced-response results are better captured than with models that use single-frequency influence coefficients. A low-speed compressor stage is also modeled to demonstrate the multistage capability of the method. These examples demonstrate how model order reduction can be used to systematically improve the versatility, fidelity, and range of applicability of the low-order aerodynamic models typically used for incorporation of CFD results into aeroelastic analyses.
Read moreMEMS Heat Transfer Arnoldi-based Macromodels and the Study of Minimum Required Orders
In this work, a model order reduction (MOR) technique for heat-transfer system-level modeling is presented. A heat transfer solver using the finite difference method (FDM), which is appropriate for MEMS thermal analysis, is implemented. The numerical models generated by the FDM solver then were successfully reduced into low-order compact models by an Arnoldi-based model-order-reduction technique. The compact macromodels can be easily inserted into system-level or circuit simulators. We have demonstrated that the macromodel results for a thermal actuator are in good agreement with the experimental results. We also use the same technique on periodic surface heat flux problems to observe the relationship between frequency and minimum required order of the reduced model under specific error tolerance.
Read moreReduced Order Model Based Controller Design for Feedback-Controlled Cylinder Wake
Feedback flow control is an emerging discipline which aims at applying the methods of closed loop feedback control to problems in fluid dynamics. A challenging area for application, which has drawn considerable academic research, concerns the control of absolute instabilities associated with the von Karman vortex street that develops in the wake of a circular cylinder. The need for meaningful real-time control leads to the requirement of developing an appropriate low order model. A two dimensional, high resolution simulation is used to develop a neural network based low-dimensional model for controller design. Actuation is implemented as displacement of the cylinder normal to the flow. This control approach uses a low dimensional model based on a 15 mode Double Proper Orthogonal Decomposition (DPOD) applied to the velocity field. The truncated DPOD modes, used to construct a dynamic mathematical model of the wake, accurately predict the wake flow dynamics within the lock-in region at low forcing amplitudes. This low-dimensional model, derived using non-linear artificial neural network based system identification methods, is robust and accurate and can be used to simulate the dynamic behaviour of the wake flow. The control strategy involves the estimation of the DPOD modes and a respective feedback command based on these estimates. The control approach is based on both the Karman fluctuating DPOD mode as well as the Karman shift mode. The shift mode provides corrections for spatial variations in the POD Eigenfunctions which are caused by the feedback control induced modification of the wake. Using the reduced-order model, numerical investigations are conducted to determine effective controller gains. High resolution simulation having 63,700 nodes show that the developed control law stabilizes all 15 modes, the controller succeeds in substantially reducing drag and fluctuating lift. While the reduced order model is shown to be a very useful tool for controller development, major issues are identified and suggested remedies are discussed.
Read moreA Mode-Accelerated XXr (MAX) method for complex structures with large blends
A Mode-Accelerated XXr (MAX) method for complex structures with large blends
Model order reduction using spline-based dynamic multi-point rational interpolation for passive circuits
The efficient modeling of integrated passive components and interconnects is vital for the realization of high performance mixed-signal systems. In this paper, we develop a dynamic multi-point rational interpolation method based on Krylov subspace techniques to generate reduced order models for passive components and interconnects that are accurate across a wide-range of frequencies. We dynamically select interpolation points by applying a cubic spline-based algorithm to detect complex regions in the system's frequency response. The results indicate that our method provides greater accuracy than techniques that apply uniform interpolation points.
Read moreStable biased reduced order models using the Routh technique
Over the past decade a number of different methods have been proposed for approximating high order dynamical systems by lower order models. The most common applications of reduced order models are in the simulation of complex systems and in the design of sub-optimal controllers.
Read morePID Controller Design & Optimization Using Reduced-Order Modeling through Factor-Division & Dominant Pole Retention Techniques
The Model Order Reduction has indeed gained significant attention due to the advancements in automation and control system engineering. The need of more accurate reduced-order models arises for achieving effective control of the process or the plant. The objective of MOR is to reduce the complexity of higher order model into lower order model while preserving the system's critical characteristics. The two commonly used methods i.e. Factor Division and Dominant Pole Retention are employed for reducing higher-order models. Dominant pole retention selects the dominant poles of the higher-order complex system and transfers them to the desired lower-order system to obtain the characteristic equation of the desired system. Unknown parameters of numerator are computed using factor division algorithm. The effectiveness of the proposed method is verified by comparing it with other recently published works through examples. Further, PID (Proportional-Integral-Derivative) controller design is a well-established technique for controlling dynamic systems. Once a reduced-order model is obtained, a PID controller is designed based on the model's characteristics. Particle Swarm Optimization (PSO) approach has been used to find the unknown controller parameters, resulting in an optimized controller that can provide superior performance to the system. The time domain characteristics and the response of the original and the reduced systems have been examined to test the efficacy of the method proposed in this article. It was observed that the use of PID controller improves overall time-domain performance of the system with negligible steady-state error.
Read more