• Home
  • Search
  • Seismic performance analysis of steel frame structures with separated three‐dimensional isolation
  • Cite Icon6
  • https://doi.org/10.1002/eer2.41Copy DOI Icon

Seismic performance analysis of steel frame structures with separated three‐dimensional isolation

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Abstract Three‐dimensional (3D) base isolation can significantly improve the seismic performance of structures. However, significant 3D movement coupling and rocking behavior of the superstructure due to the high gravity center of the structure can be observed, which will lead to a complex design of the isolation system and the isolators. In addition, as the 3D isolators are installed beneath the structures, they need to support the heavy weight of the superstructure with low vertical stiffness. It is difficult to meet both the vertical load and stiffness design demands of the isolators using traditional isolation materials and mechanisms, especially for large‐size structures. A separated 3D isolation scheme is proposed by installing the horizontal isolation at the base of the superstructure and the vertical isolation under the floor slabs. Simulations are carried out to examine the dynamic responses including the acceleration, inter‐storey drift, and stress of structural members of a typical steel frame structure with the separated 3D isolation scheme. The isolation effect was also studied by shaking table tests of a two‐storey steel frame structure. The simulation and test results show that the proposed separated 3D isolation scheme has high performance in mitigating the structural accelerations in both horizontal and vertical directions, and the vertical load on isolators. The rocking behavior of the structure is effectively restrained for the separated 3D isolation scheme due to a low mass center configuration of the vertically isolated slabs. Although the isolation of the floor slabs from the beams in the structure with separated 3D isolation weakens the constraint of the floor slabs to the beam and column members as in a traditional frame structure, the horizontal isolation at the base of the superstructure reduces the adverse effect and the stress of structural members is similar to that in a horizontal base‐isolated structure and significantly lower than that in a base‐fixed structure. In addition, as the vertical isolation is installed under the slabs, the vertical load on the vertical isolators is small and it is easy to design the isolators.

Similar Papers
  • Research Article
  • Citations62

Distributed plasticity analysis of steel frame structures comprising non-compact sections

  • Apr 07, 2000
  • Engineering Structures
  • Philip Avery +1
  • Research Article
  • Citations2

Refined Plastic Hinge Analysis of Steel Frame Structures Comprising Non-Compact Sections I: Formulation

  • Oct 01, 2000
  • Advances in Structural Engineering
  • P Avery +1
  • Research Article

Performance Verification of Vertical Seismic Isolation Equipment Using Negative Rigidity Mechanism

  • Jan 01, 2022
  • The Proceedings of the Dynamics & Design Conference
  • Yudai Ishitobi +4
  • Research Article
  • Citations21

Shaking table test of space double-layer cylindrical reticulated shell with three-dimensional isolation bearing

  • Dec 22, 2021
  • Journal of Constructional Steel Research
  • Gui-Bo Nie +4
  • Research Article

Seismic performance analysis of braced steel structures based on vibration experiments and finite element simulation

  • May 09, 2025
  • PLOS One
  • Nan Cui +1
  • Research Article
  • Citations15

Time domain intrusive probabilistic seismic risk analysis of nonlinear shear frame structure

  • Jun 06, 2020
  • Soil Dynamics and Earthquake Engineering
  • Hexiang Wang +6
  • Conference Article
  • Citations7

In-Plane and Out-of-Plane Dynamic Response Predictions of a Truck Tire Using Detailed Finite Element and Rigid Ring Models

  • Jan 01, 2005
  • Seokyong Chae +4
  • Research Article
  • Citations7

Seismic performance of recentering energy dissipation bracing with pendulum in prefabricated steel frame structure systems

  • May 04, 2024
  • Journal of Constructional Steel Research
  • Xue-Chun Liu +3
  • Conference Article
  • Citations6

Empirical formula of fundamental period for steel structure based on seismic response record

  • Apr 01, 2011
  • Maosheng Gong +2
  • Research Article

The Passive Energy-Dissipation Study of Braced Steel Frame Structure

  • Dec 01, 2010
  • Advanced Materials Research
  • Wen Xia Luo +2
  • Research Article
  • Citations3

Experimental Study on Vertical Stiffness of WJ-8 Fastener for High-Speed Railway

  • Jan 01, 2015
  • Applied Mechanics and Materials
  • Can Liu +4
  • Research Article
  • Citations14

Mechanical behaviors of Tou-Kung in historic timber structures subjected to vertical load

  • Dec 08, 2022
  • Structures
  • Xiaoyang Dong +2
  • Research Article
  • Citations16

Study of isolation effectiveness of nuclear reactor building with three-dimensional seismic base isolation

  • Sep 06, 2021
  • Engineering Computations
  • Xiuyun Zhu +3
  • Research Article

Investigating the effect of infill walls on steel frame structures

  • Mar 03, 2018
  • Challenge Journal of Structural Mechanics
  • Osman Fatih Bayrak +3
  • Research Article
  • Citations8

A Response Spectrum Method for Base-Isolated Structures with Equivalent Base Excitations

  • Feb 01, 2023
  • Journal of Structural Engineering
  • Xiaoxiang Lin +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.