Abstract

This paper assesses the reliability of code-compliant linear and nonlinear dynamic analyses for irregular buildings with base isolation system (BIS). Comprehensive analyses are carried out for a case study comprising a large reinforced concrete multi-storey framed hospital with 327 high-damping rubber bearings. Spectral and time history (linear and nonlinear) analyses were performed on the three-dimensional (3D) finite element model (FEM) of the structure; simplified analyses were also conducted on single-degree-of-freedom (SDOF) systems. It is found that, at damageability limit state, the values of maximum interstorey drifts (d/h) computed with spectral analyses on the three-dimensional FEM range between 1/6 and 1/10 of the code limit (d/h = 0.33%); thus more stringent code limits should be required for buildings with BISs. The maximum floor acceleration is reduced by about 70% with respect to the ground acceleration (free field site); the acceleration profile is uniform along the height of the multi-storey frame. Threshold values of floor accelerations to assess the seismic performance of equipments in buildings with BIS are lacking. At ultimate limit state (ULS), spectral analyses provide values of actions and deformations that are less conservative than those derived through time history analyses. To perform reliable dynamic analyses of base isolated buildings it is crucial to select natural earthquake ground motions compliant with the fundamental period of vibration of the structural system. Nevertheless, it is not straightforward to select adequate natural strong motions in the catalogues available world-wide; buildings incorporating BISs possess periods of vibration which are generally higher than 2.0 s. As a result, distant and high-magnitude earthquakes are effective for base isolated buildings; nevertheless, such earthquakes are scarce in the seismic databases. The outcomes of the present study also demonstrate that simplified linear analyses tend to provide estimates of the response quantities, displacements of base isolators and base shear of the superstructure, which can be reliably employed at preliminary design stage. Spectral analysis results of the 3D model tend to match those of the SDOF systems, even for irregular superstructure, provided that modal mass participating ratios are greater than 85–90%. The results of spectral analyses on both SDOF and three-dimensional FEM envelope the outcomes of linear time histories.

Similar Papers
  • Conference Article
  • Citations5

Base Isolation for Industrial Structures: Design and Construction Essentials

  • May 18, 2010
  • Structures Congress 2010
  • Todd W Erickson +1
  • Research Article
  • Citations59

Nonlinear dynamic analysis for multi-storey RC structures with hybrid base isolation systems in presence of bi-directional ground motions

  • Jul 22, 2016
  • Composite Structures
  • Donato Cancellara +1
  • Dissertation
  • Citations7

Seismic Performance Comparison of a Fixed-Base versus a Base-Isolated Office Building

  • Aug 14, 2013
  • Nicholas Reidar Marrs
  • Research Article

Hysteresis Loops of Base Isolation System - An Overview

  • Mar 01, 2021
  • Key Engineering Materials
  • M.A Amir +1
  • Conference Article

Dynamic Analysis of a Smart Base-Isolation System Based on MR Elastomers

  • Jan 01, 2010
  • Hyung-Jo Jung +2
  • Research Article
  • Citations18

A smart mechatronic base isolation system using earthquake early warning

  • Feb 01, 2019
  • Soil Dynamics and Earthquake Engineering
  • Ricky W.K Chan +2
  • Research Article

LARSA 2000: Seismic Analysis of Bridges with Seismic Isolation and Energy Dissipation Devices

  • Jan 01, 2000
  • Transportation Research Record: Journal of the Transportation Research Board
  • Panos Tsopelas +1
  • Research Article
  • Citations10

Evaluation of efficiency of ALSC floating-sliding base-isolation system based on shake table test and floor response spectra

  • Sep 21, 2009
  • Bulletin of Earthquake Engineering
  • Ljubomir Tashkov +3
  • Research Article
  • Citations258

Development and characterization of a magnetorheological elastomer based adaptive seismic isolator

  • Jan 31, 2013
  • Smart Materials and Structures
  • Yancheng Li +3
  • Conference Article

A new type of electromagnetic system for magnetorheological elastomer (MRE)-based base isolation system

  • Mar 27, 2019
  • Yongmoon Hwang +3
  • Research Article
  • Citations4

Spectral analysis of waves produced by HSC for coastal management

  • Oct 01, 2014
  • Journal of Marine Science and Technology
  • G Benassai +2
  • Research Article
  • Citations42

Seismic responses of secondary systems in base-isolated structures

  • Jan 01, 1992
  • Engineering Structures
  • Fa-Gung Fan +1
  • Research Article

Dynamic nonlinear analysis and assessment of structures with friction base isolation devices

  • Dec 10, 2025
  • Mathematics and Mechanics of Solids
  • Donato Cancellara +1
  • Research Article

Seismic Performance Enhancement of a Reinforced Concrete Building Using an RB-HDRC Base Isolation System

  • Apr 04, 2026
  • G-Tech: Jurnal Teknologi Terapan
  • Nur Khofifah +1
  • PDF
  • Research Article
  • Citations13

Experimental and numerical assessment of grout-filled tennis balls as seismic isolation bearings

  • Aug 11, 2023
  • Engineering Structures
  • Antonios A Katsamakas +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.