- Research Article
41
- 10.6100/ir631615
On the conductivity of PEDOT:PSS thin films
- Nov 18, 2015
- Data Archiving and Networked Services (DANS)
- Am Alexandre Nardes
On the conductivity of PEDOT:PSS thin films
Scanning probe microscopy are an extraordinary tools for surfaces characterization at nano and atomic scale and also for nanofabrication whose major limitation depends on the serial nature of the related techniques. Here we propose an interesting approach applied to a supramolecular system (rotaxane) that contributes to overcome this limitation. When a local mechanical perturbation is applied to the surface of a thin film of a rotaxane, the molecules self-organize into periodic arrays of discrete dots or lines. The dimensionality of the nanostructures depends on whether the mechanical stimulus acts along a 1D line or over a 2D area. The size and periodicity of the patterns are controlled solely by the film thickness. The phenomenon can be exploited as a new bottom-up nanofabrication method.
On the conductivity of PEDOT:PSS thin films
On the conductivity of PEDOT:PSS thin films
Thermo- and photo-driven crystalline molecular switches comprising pseudorotaxanes
This thesis describes the thermo- and photo-driven molecular switches comprising ferrocene-containing pseudorotaxanes in the solid state. Chapter 1 presents an overview of supermolecular chemistry as well as the purpose of this project. Chapter 2 describes the reversible mechanical deformations of the single crystals of the pseudorotaxanes caused by a combination of temperature control and light-irradiation. Laser irradiation to the ferrocenyl group of the pseudorotaxane induces molecular structural changes in the crystals: it triggers a crystal-to-crystal thermal phase transition deforming the crystal shape at 124 oC; it causes rapid and reversible expansion of the crystal at room temperature. In addition, the local laser irradiation to a part of the single crystal enables selective transport of micro-particles. Chapter 3 describes the preparation and morphological studies of the thermally responsive pseudorotaxane films. The thin films of the pseudorotaxane molecule can be prepared on a glass or SiO2 substrates by a solution casting method, which affords the polycrystalline films without dissociation of the pseudorotaxane molecule. Obtained films are characterized by X-ray diffraction, differential scanning calorimetry (DSC), polarized optical microscopy, and grazing incident wide-angle X-ray scattering (GIWAXS) measurement with temperature control. The pseudorotaxane film on the substrate exhibits the reorganization of the molecule to give a large crystal face with 50-100 μm on heating, followed by the reversible solid-to-solid thermal phase transition on heating and cooling. GIWAXS analysis can conduce to the molecular alignment of the pseudorotaxane in the film; the pseudorotaxane adopts edge-on orientation, in which one-side of oligo-ethylene glycol group -(CH2CH2O)n- of the dibenzocrown ether molecule in the pseudorotaxane lies on the substrate, probably due to the molecule-surface interaction and formation of the bulky interlocked structure. Chapter 4 described the synthesis and characterization of a new pseudorotaxane composed of 4,4’,5,5’-tetrabromodibenzo[24]crown-8 ether as a ring molecule and ferrocene-containing ammonium cation as an axle molecules. The optical properties of the pseudorotaxane are observed and related to the molecular alignment in the single crystal state. Chapter 5 presents the conclusions of the project and gives forecast of this research. Finally chapter 6 presents the experimental conditions.
Read moreNew photoplastic fabrication techniques and devices based on high aspect ratio photoresist
This thesis deals with the development of microfabrication technologies based on photoplastic structuring by lithographic and molding techniques. These technologies, combined with an original releasing method, allow for the simple fabrication of pseudo three-dimensional, soft, photoplastic microstructures with features and shapes that are difficult to obtain with standard micro-machining. The photoplastic material used is the SU-8 photoresist, a material that is used increasingly in the growing field of micro-electro-mechanical systems (MEMS). Photoplastic SU-8 microstructure fabrication is based on a combination of multi-layer spin-coating, molding and photolithographic processing of the resist on a prestructured silicon substrate. The final product is obtained by release of the structure from the substrate. This thesis describes several SU-8 microstructures which have been developed with an emphasis on atomic force microscopy (AFM) and scanning-near field optical microscopy (SNOM) probes. Scanning probe microscopy is a well-established technique for surface analysis, but batch-fabricated, low-cost probes still remain a challenging issue. Using a polymer for the cantilever facilitates the realization of mechanical properties that are difficult to achieve with classical silicon technology. The design, fabrication and testing of single lever and cassettes of multiple single-lever probes are presented and demonstrates the potential for fabrication structures with complicated shape and features. The fabrication process for SU-8 AFM probes is a simple batch process in which the integrated tips and the levers are defined in one photolithography step. Tip radii of curvature smaller than 15 nm have been obtained. The cantilever thickness depends on the spin-coating parameters, hence it can be very well controlled over a full wafer. Photoplastic cantilevers with thicknesses ranging from 1 to 6 μm have been produced. Imaging soft, condensed matter with photo-plastic levers, which uses laser beam deflection sensing, exhibits a resolution that compares well with that of commercially available silicon cantilevers. Lateral resolution of 5–6 nm has been estimated from imaging DNA-plasmid molecules. A vertical resolution of the order of 0.1 nm has been found. A similar fabrication technique was also developed to fabricate photo-plastic tips for SNOM that are to be attached to optical fibers. This technique allows optical apertures to be integrated at the end of the well-defined tip directly by probe fabrication, without the need for any post-processing for the aperture formation. Sub-100 nm aperture have been fabricated using this technique. Simple fabrication, as well as topographical and optical imaging demonstrate the potential of photoplastic-based probes for both AFM and SNOM applications, as well as for future combined probes development. In addition, the fabrication of functional microstructures by using SU-8 processing needs to be combined with other microfabrication techniques. Simple releasing of the molded structures from the substrate is especially of great importance. A sacrificial layer technique based on electrochemical etching enhancement has been developed and combined with the fabrication of the different photoplastic SU-8 probes presented. This technique allows the fast releasing of large microstructures and has been demonstrated by releasing other SU-8 photoplastic microfabricated devices.
Read moreScanning Probe Microscopes
INTRODUCTION Background History of Microscopy SCANNING PROBE MICROSCOPES (SPMS) Scanning Tunneling Microscope Electron Tunneling Atomic Force Microscope (AFM) Modes of Operation of AFM Simultaneous AFM and Scanning Near-Field Fluorescence (SNOM and SNOM-AFM) Friction Force Microscopy (FFM) STM and AFM Studies under Fluids Sample Preparation Procedures for STM and AFM Calibration and Image Analysis of STM and AFM Comparative Studies of Diverse Molecules by STM and AFM LIPID-LIKE MOLECULES ON SOLIDS AND SAMS Collapsed Lipid Monolayers (Self-Assembly) Domain Patterns in Monomolecular Film Assemblies Mixed Lipid Molecule Assemblies Holes in LB Films of Self-Assembly Monolayers Visualization of Vesicles by AFM LB Films of Liquid Crystals STM and AFM Studies of Diverse Molecules on Solids STM Studies on the Effect of Functional Group BIOPOLYMERS AND SYNTHETIC POLYMERS STRUCTURES BY STM AND AFM DNA Structures by STM and AFM SPM Studies of Three-Dimensional Protein Structures Protein Adsorption Studies by AFM Biological Macromolecular Structures Synthetic Polymers Studies by SPMs Mixed Monolayers of Macromolecules and Lipids Diverse Macromolecular Properties as Studied by SPMs Monolayers of Synthetic Polyamino Acids Biopolymer SAM Structures at Interfaces by STM and AFM CRYSTAL STRUCTURES BY STM AND AFM Crystal Structures of Small Molecules Surface Adsorption Studies by SPMs Macromolecule Crystals by STM and AFM STUDIES OF SOLID SURFACES BY SPMS Wetting Properties of Solid Surfaces AFM Analyses of Surface Acid-Base Properties Measurement of Attractive and Repulsive Forces by Atomic Force Microscope (AFM) DIVERSE APPLICATIONS OF SPMS (STM AND AFM, ETC.) AND NANOTECHNOLOGY STM and AFM in Organic Chemistry Semiconductor Study by SPM STM and AFM in Inorganic Chemistry Nanolithography and Nanomachining Qualitative and Quantitative Analyses at Nanoscale Application of SPMs under Dynamic Conditions Application of AFM to Immunodiagnostic Systems Applications of STM and AFM in Industry SPM Studies of Nanoscale Reactors Nanoscale Evaluation of Surface Roughness by SPMs Application of STM and AFM in Pollution Control Friction Force Microscope (FFM) Time-Resolved Analyses by STM REFERENCES
Read moreDevelopment of novel nanomanipulators based on scanning probe microscopes
Scanning probe microscopes (SPMs) are well known as surface imaging tools with nanometer scale resolution. SPMs can be used not only for surface observation but also for local surface manipulation. We have developed a nanometer-scale manipulator based on an atomic force microscope (AFM) which can be operated under observation using a scanning electron microscope. Nano manipulations of biological samples using the haptic control system of the AFM are demonstrated. Furthermore, we introduce a real time nanomanipulation system based on a high-speed atomic force microscopy (HS-AFM) . Even under surface manipulation using the AFM probe, the topographical image of the manipulated surface is periodically updated by HS-AFM. This system would be very useful for real time nano manipulation and fabrication of sample surfaces.
Read moreMulti-Channel Exploration of O Adatom on TiO2(110) Surface by Scanning Probe Microscopy.
We studied the O2 dissociated state under the different O2 exposed temperatures with atomic resolution by scanning probe microscopy (SPM) and imaged the O adatom by simultaneous atomic force microscopy (AFM)/scanning tunneling microscopy (STM). The effect of AFM operation mode on O adatom contrast was investigated, and the interaction of O adatom and the subsurface defect was observed by AFM/STM. Multi-channel exploration was performed to investigate the charge transfer between the adsorbed O and the TiO2(110) by obtaining the frequency shift, tunneling current and local contact potential difference at an atomic scale. The tunneling current image showed the difference of the tunneling possibility on the single O adatom and paired O adatoms, and the local contact potential difference distribution of the O-TiO2(110) surface institutively revealed the charge transfer from TiO2(110) surface to O adatom. The experimental results are expected to be helpful in investigating surface/interface properties by SPM.
Read moreMicrofabricated electrically conducting and wear-resistant nanoprobes for scanning probe applications
The era of scanning probe microscopy (SPM) started twenty years ago. A cut gold cantilever with a glued diamond stylus served as the scanning probe. Within a few years the crystalline silicon (Si) became the – up to today – predominant SPM probe material. The rise of micromachining provided straightforward silicon probe fabrication to yield probes with nanometre-sized tip radii. For electrically conducting SPM applications Si probes are metal coated. Wear, and melting of this coating at the tip extremity at high current densities in the order of 108 A/cm2 disable the probe and thus are serious limitations. This thesis addresses and tackles these problems. The approach consisted of a surface micromachining technique using an oxidation sharpened SiO2 mould to fabricate full metal cantilevers with integrated metal nanometrically sharp tip. The tip mould sharpness can be can be tuned by an isotropic wet etch. The used probe material should be hard, have a high melting temperature and a good electrical conduction. In addition a good resistance to oxidation is necessary. The thesis describes the design, microfabrication, characterisation and demonstrates applications of the fabricated electrically conducting probes. The body of the probe consists of the photo-polymer SU-8. The probe metals used in this work are tungsten (W), platinum (Pt) and a developed platinum-tungsten alloy, yielding tip diameters below 40 nm, 40 nm and 23 nm, respectively. The tungsten probes with initial electrical resistance of 35 Ω were 14 GPa hard though showed oxidation upon IV spectroscopy. The Pt probes with 8,1 Ω resistance did not oxidise and with limited tip melting did retain a sharpness of 40 nm tip diameter at current densities up to 1,2x108 A/cm2. The Pt probe wear resistance however, with a 7,2 GPa thin film hardness, was limited. The PtW probes were fabricated in two versions: Pt89W11 and Pt74W26 with a hardness of 11,6 GPa and 13,7 GPa, respectively. The Pt89W11 probes with 42 Ω resistance did not show any oxidation at applied current densities up to 3,1x108 A/cm2 (5 mA), while equally retaining a 40 nm tip diameter. The Pt74W26 probes with initial 76 Ω resistance oxidised at current densities between 0,6x108 A/cm2 (1 mA) and 1,4x108 A/cm2 (2,5 mA). Pt89W11 and Pt74W26 probes showed wear characteristics comparable to Si probe wear. The Pt74W26 probes outperformed the Pt89W11 probes. The feasibility of SPM measurements in (electrically conducting) contact and dynamic mode was demonstrated with the Pt and the PtW probes. As such, with a high hardness, good electrical conductivity and resistance to oxidation at elevated current densities, the Pt89W11 probes meet all requirements for a wear resistant electrically conducting SPM probe and offer an alternative to coated Si probes.
Read moreModeling scanning probe microscope lateral dynamics using the probe–surface interaction signal
In this paper, a novel scanning probe microscope (SPM) modeling technique is presented. The novelty of this technique is that it exploits the SPM's probe-surface interaction measurement capabilities [e.g., the topography signal in atomic force microscopy (AFM)] to determine the SPM's lateral positioning dynamics. SPM operation speed is limited due to mechanical vibrations induced by movement of the SPM nanopositioner. In order to facilitate high-speed SPM operation, the dynamics of the SPM can be modeled and used to design feedforward and feedback controllers that reduce nanopositioner vibrations. The proposed technique seeks to develop a transfer function model of the SPM dynamics using only the SPM probe-surface interaction signal obtained while scanning a calibration sample. The technique is presented in the context of an AFM example, errors associated with the method are analyzed, and the method is experimentally verified using a commercial AFM. Experimental modeling results show that the method is capable of modeling the dynamics of SPM systems.
Read moreZnO-Based nanostructures for gas sensing applications.
Metal oxide chemical sensors based on nanomaterials are gaining popularity and finding extensive use in automotive industries, process control and environmental monitoring. ZnO, a semiconducting metal oxide has attracted great interest over the years for its sensitivity to a variety of gases. Nanostructured sensing materials, such as thin films, nanowires, tetrapods, nanoflackes offer an inherently high surface area, reducing operating temperatures and increasing sensitivity to low concentrations of analytes. In this thesis, ZnO nanostructures have been tested as chemical sensors and a detailed study on the effect of different process parameters such as grain size, roughness, surface-to-volume ratio, depletion layer, temperature, gas concentration and material properties on gas sensitivity is presented. Initially, ZnO nanodevices were prepared with a variety of techniques, such as RF sputtering, electrodeposition, hydrothermal growth, chemical vapour deposition, thermal evaporation and controlled oxidation. The structural characterization of the nanodevices has been done by a FEI QUANTA 3D dual beam SEM/FIB machine and by a Dimension 3100 Atomic Force Microscope (AFM) (Digital Instruments) in tapping mode. X-ray diffraction (XRD) spectra were recorded on an AXS D8 diffractometer (Bruker) with a Cu Kα X-ray tube. The gas sensor substrate based on alumina consisted of Pt grid of 50nm thickness and golden contacts of 200nm thickness creating an alumina patterned substrate. The sensor deposition area was coated with ZnO nanostructures to form the sensing material. Sensing measurements are performed in a closed steel chamber where air and tested gases have been inserted. ZnO based nanostructures' response was measured in different concentrations of Ethanol, CO and NO2. Initially the role of grain size and roughness has been investigated in several thin film based nanodevices. Grain size is decreasing with increasing RF sputtering power and increasing by post-annealing treatment. Roughness instead is increasing with both the increasing of RF sputtering power and post-annealing treatment. High response was observed for those films with smaller grain size, while the roughness seems to influence very little the response of the sensor. For all thin films, the response is increasing with ii temperature and gas concentration. Recovery time and response time seem to follow a non-linear behavior with the above parameters. Extended studies have investigated the role of surface-to-volume ratio and depletion layer in the sensing performance. It has been observed that the increase of surface-to volume ratio has an important effect on the sensitivity, increasing, more than twice the response of such a device in respect to another that is based on a ZnO thin film. On the other hand, the dimensions of a nanostructure play the most crucial role in the depletion layer width in respect to the sensing properties. The diameter of a nanowire should be comparable with its depletion layer width. In this case the depletion layer has strong effect, which makes the sensor's response depend also on it. The sensing properties of all fabricated structures have been compared to find the optimum sensor that could face the demands of automotive industries. All fabricated structures have been compared in different configurations to find out which one presents the best sensing performance. To that direction sensors based on thin film, tetrapods, nanowires, nanoflackes have been tested in same environmental conditions. Advanced nanostructures present better sensing properties. Sensing response of every advanced nanostructure presents more than double sensing response than every thin film-based nanostructure. Comparing the advanced nanostructures with each other, tetrapods based sensor has higher response and recovery time, while the sensitivity is slightly higher for the nanowires-based sensor. Theoretical studies have been performed by ab-initio simulations in NO2 environment. They have revealed that the sensing mechanism is driven almost exclusively by competitive adsorption between NO2 and atmospheric oxygen mediated by temperature change. The influence of the NO2 on the electronic properties of ZnO has been assessed and it is in accordance with the experiments. Our future work is the investigation of other materials for the development of sensing nanodevices targeting to develop more sensitive nanosensors in the same or lower cost. Additionally, the investigation of other growth techniques that could develop more complicated structures in low cost is another point of interest for the future
Read moreChemical identification at atomic resolution on Cu(110)-O surface using NC-AFM
Scanning probe microscope (SPM)(including atomic force microscope (AFM), scanning tunneling microscope (STM) and Kelvin force probe microscope (KPFM)), etc.), tips have a great influence on physical and chemical properties of the sample surface. In this research, we explore the relationship between tip and structure of sample surface using AFM on Cu(110)-O surface. We observed two different types of c(6×2) phase on which Cu shows bright spot when the tip apex is O-terminated; on the other hand, O atoms shows bright spot when the tip apex is Cu-terminated. We also obtained that the tip has a great influence on the resolution, imaging, etc. Thus, we gave an explanation for both phenomena. This technique can be used for the fingerprinting and the identification of the chemical species on sample surfaces. And it is very important for the development of SPM technique.
Read moreMechanisms of surface anodization produced by scanning probe microscopes
The direct modification of silicon and other semiconductor and metal surfaces by the process of anodization using the electric field from a scanning probe microscope in conjunction with the absorbed water from the atmosphere as the electrolyte is one promising method of accomplishing direct write lithography for the electron device fabrication using scanning probe microscopes. Both scanning tunneling microscopes and conductive-tip atomic force microscopes have been used for anodization with the work reported here primarily accomplished with a conductive-tip atomic force microscope. We have found that the terminating thickness of the scanning probe microscope induced oxide is governed by the diffusion limited electric field at the surface (which in this case is a function of the scanning probe microscope tip potential), with many similarities to liquid electrolyte anodization process. In particular, when using atmospheric water as the electrolyte on a silicon substrate and a conductive-tip atomic force microscope with a −7 to −10 V tip potential, the terminating electric field that is reached as the silicon dioxide thickness increases is to its final value of 80 Å is ∼1×107 V/cm. This is consistent with the diffusion limited electric field that is observed in many other anodization processes and the native oxidation of silicon (Mott–Cabrera process).
Read moreAtomic and magnetic force microscopy imaging of thin‐film recording heads
Investigations on the use of the scanning probe microscope (SPM) in the atomic force microscopy (AFM) mode for topography imaging and the magnetic force microscopy (MFM) mode for magnetic imaging are presented for a thin‐film recording head. Results showed that the SPM is suitable for imaging the surface profile of the recording head, determining the width of the pole gap region, and mapping the magnetic field patterns of the recording head excited under current bias conditions of different polarity. For the cobalt sputter‐coated tips used in MFM imaging, it was found that the magnetic field patterns obtained under different polarities of the current bias to the recording head were similar. This can be explained by the nature of the thin‐film MFM tip, in which the direction of the tip magnetic moment can follow the stray magnetic field of the sample as the current bias to the recording head reverses in direction.
Read morePolarization in Wide Bandgap Semiconductors and their Characterization by Scanning Probe Microscopy
In this chapter, we discuss recent developments in the characterization of polarization doped wide bandgap semiconductor (WBS) heterojunctions with an emphasis on characterization by scanning probe microscopy (SPM). Wide bandgap semiconductors, such as SiC and GaN, have a wide variety of applications in electronic and optoelectronic devices [1–6]. The operation of devices made from these materials is dominated by the polarization properties of III-N and SiC semiconductor crystals. For example, polarization doped 2 dimensional electron gas (2DEG) channels in undoped GaN/AlGaN and SiC polytypic heterojunctions have been fabricated with current densites in excess of 1A/mm. Other effects, such as surface charge instability stemming from polarization, offer interesting potentials and challenges.While some of these effects may be studied using more conventional techniques such as currentvoltage (IV) and capacitance-voltage (CV) techniques (described in sections 2 and 3), others require probes capable of investigation on the nanometer scale. Transmission electron microscopy (TEM) can be used to investigate such polarizationinduced phenomena with atomic resolution, but involves destructive and laborious sample preparation. SPM techniques offer powerful, non-destructive tools to effectively and conveniently probe electronic materials and devices. Since the discovery of scanning tunneling microscopy (STM) in 1981 by Binnig and Rohrer [7], the field of SPM has advanced to encompass a large number of variations including, (i) STM, (ii) Atomic force microscopy (AFM), (iii) Electrostatic force microscopy (EFM), (iv) Scanning capacitance microscopy (SCM), (v) Scanning conduction microscopy (SCM), (vi) Magnetic force microscopy (MFM), (vii) Piezoelectric force microscopy (PFM), and (vii) Near field scanning optical microscopy (NSOM). Of the above modes, the first five modes have been extensively used for semiconductor characterization [8–15]. For WBS characterization, especially III-N, AFM, EFM and SCM modes are the most important due to the strong polarization of III-N and SiC. In the latter half of this chapter, we focus on the characterization of III-N by EFM operated in
Read moreScanned Probe Microscopy (AFM, et al.): How to Choose and Use
Virtually everyone associated with a science or engineering discipline has some baseline knowledge of optical microscopy; and most attendees at this conference have a reasonable exposure to at least some form of electron microscopy. The many developments in instrumentation and application require the modern microscopist to continuously follow the literature to stay aware of the ongoing improvements and advances in these microscopies. While electron and optical microscopes have been around for many decades, the family of microscopes known as Scanned Probe Microscopy (SPM) are just entering their second decade; and are actually in there first decade of widespread use. The most commonly used forms of scanned probe microscopy are the force microscopes; commonly referred to as Atomic Force Microscopy (AFM). This includes a wide variety of microscopy modes that are generally made available as modifications of a basic AFM. Before describing the basic versions of AFM, the fundamentals of instrument design must be addressed.
Read moreDynamic Measurements with Scanning Probe Microscopy: Surface Studies Using Nanostructured Test Platforms of Metalloporphyrins, Nanoparticles and Amyloid Fibrils
A hybrid imaging mode for characterization of magnetic nanomaterials has been developed, using atomic force microscopy (AFM) combined with electromagnetic sample actuation. Instead of using a coated AFM probe as a magnetic sensor; our strategy is to use a nonmagnetic probe with contact mode AFM to characterize the vibration of magnetic and superparamagnetic nanomaterials responding to the flux of an AC electromagnetic field. We refer to the hybrid imaging mode as magnetic sample modulation (MSM-AFM). An oscillating magnetic field is produced by applying an AC current to a wire coil solenoid placed under the sample stage for tuning selected parameters of driving frequency and strength of the magnetic field. When the AC field is on, the AFM probe is scanned in contact with the sample to sense periodic changes in the force and motion of vibrating nanomaterials. With MSM, responses of both the amplitude and phase signal along with spatial maps of the topography channel can be collected simultaneously. A requirement for MSM is that the samples can be free to vibrate, yet remain attached to the surface. Particle lithography was used to prepare well-defined test platforms of ring structures of magnetic or superparamagnetic nanomaterials. Capillary filling of polydimethylsiloxane (PDMS) molds was applied to generate stripes of FeNi3 nanoparticles with microscale dimensions as test platforms. The MSM-AFM imaging mode was used successfully to characterize nanomaterials of FeNi3 nanoparticles, cobalt nanoparticles, octa-substituted porphyrin nanocrystals and ionic liquid nanoGUMBOS with dimensions ranging from 1 to 200 nm. Dynamic MSM-AFM measurements can be obtained by placing the tip on a vibrating nanoparticle and sweeping the frequency or field strength. Changes in frequency spectra and vibrational amplitude can be mapped for nanoparticles of different sizes, shapes and composition. The MSM-AFM imaging mode provides a useful tool for investigating changes in size dependent magnetic properties of materials at the nanoscale. Samples of designed amyloid proteins were characterized ex situ using scanning probe microscopy. The progressive growth and fibrillization of amyloid â over extended time intervals was visualized with high resolution using AFM.
Read more