In this paper, we propose an improved method of In-core neutron flux estimation using Inconel Self Powered Neutron Detectors (SPNDs). The method proposed here is based upon multi-sensor based particle filter utilizing a number of uniformly distributed SPNDs along with the out-core ionization chambers which measure the overall flux. The proposed method estimates the neutron flux of large non-linear core volume involving stiff non-linearities with non-Gaussian uncertainties both in the process and sensor model. We propose an improved particle filtering based data fusion algorithm on multi-sensor network for flux estimation under nonlinear non-Gaussian environment. The nonlinear system in our study is a large core nuclear reactor measured through in-core Self Powered Neutron Detectors. Many critical applications such as reactor protection and control rely upon the neutron flux information and thus make the reliability of data an utmost important. The point kinetic model based on neutron transport theory conveniently explains the dynamics of nuclear reactor. The state equation in point kinetic model is stiff nonlinear set of equations. The neutron flux in the large core, loosely coupled reactor are sensed by multiple sensors measuring point fluxes located at various locations inside the reactor core. The flux values are coupled to each other through diffusion equation. The coupling facilitates redundancy in the information. The multiple independent information about the localized flux peaking can be fused together to enhance the estimation accuracy to a great extent. In our work, we establish, observation model for the neutron flux sensor used for large core flux measurement i.e. Self Powered Neutron Detectoric document.

Similar Papers
  • Conference Article
  • Citations1

Loss of Representativeness of the Fixed Incore Instrumentation of the EPR™ Reactor

  • Jul 07, 2014
  • Volume 1: Plant Operations, Maintenance, Engineering, Modifications, Life Cycle and Balance of Plant; Nuclear Fuel and Materials; Plant Systems, Structures and Components; Codes, Standards, Licensing and Regulatory Issues
  • Brice Jardiné +2
  • Research Article
  • Citations22

Fault detection and isolation for self powered neutron detectors based on Principal Component Analysis

  • Jun 02, 2015
  • Annals of Nuclear Energy
  • Xingjie Peng +2
  • Research Article
  • Citations23

Self powered neutron detectors as in-core detectors for Sodium-cooled Fast Reactors

  • Apr 07, 2017
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • V Verma +5
  • Research Article
  • Citations3

Precise Control of Neutron Irradiation Fluence in the Neutron Transmutation Doping Process at HANARO Using SPND and Zirconium Foils

  • Jun 01, 2016
  • IEEE Transactions on Nuclear Science
  • Myong-Seop Kim +1
  • Research Article
  • Citations10

Deconvolution-based real-time neutron flux reconstruction for Self-Powered Neutron Detector

  • Nov 20, 2017
  • Nuclear Engineering and Design
  • Qingmin Zhang +10
  • Research Article
  • Citations9

A Simple Iterative Method for Compensating the Response Delay of a Self-Powered Neutron Detector

  • May 08, 2017
  • Nuclear Science and Engineering
  • Qingmin Zhang +4
  • Research Article
  • Citations10

Current compensation for material consumption of cobalt self-powered neutron detector

  • Sep 21, 2019
  • Nuclear Engineering and Technology
  • Xinxin Liu +4
  • Research Article
  • Citations2

CONDITION MONITORING OF SELF-POWERED NEUTRON DETECTORS IN THE INCORE NUCLEAR INSTRUMENTATION SYSTEM UNDER TRANSIENTS

  • Mar 01, 2023
  • Kontrol'. Diagnostika
  • A M Pankin +2
  • Research Article

Reactor test of beryllium as self-powered neutron detector emitter for fast neutron flux measurement

  • Jan 01, 2025
  • EPJ Web of Conferences
  • Elsa Dupin +5
  • Book Chapter
  • Citations2

Self-Powered Neutron Detectors for Measuring Epithermal Neutron Flux

  • Jan 01, 1989
  • Mn Agu +1
  • Research Article
  • Citations6

Determination of control rod positions during fuel life-cycle using fixed in-core Self-Powered Neutron Detectors of Tehran Research Reactor

  • Mar 07, 2018
  • Nuclear Engineering and Design
  • M.S Terman +2
  • Research Article

Differential sensitivity of long self-powered neutron detectors

  • Feb 01, 1970
  • Nuclear Instruments and Methods
  • O Strindehag +1
  • Conference Article
  • Citations3

Benchmarking the NEM Real-Time Core Model for VVER-1000 Simulator Application: Asymmetric Core

  • Jun 26, 2016
  • Emiliya Georgieva +3
  • Research Article
  • Citations20

Self-Powered Detector Response to Thermal and Epithermal Neutron Flux

  • Apr 01, 1991
  • Nuclear Science and Engineering
  • M N Agu +1
  • Research Article
  • Citations6

Compton-emissive hafnium detector of neutrons for in-core monitoring

  • Sep 25, 2018
  • Nuclear Physics and Atomic Energy
  • A.L Ulybkin +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.