• Home
  • Search
  • Sensitive-volume localization for in vivo NMR using heteronuclear spin-echo pulse sequences.
  • Cite Icon11
  • https://doi.org/10.1002/mrm.1910020314Copy DOI Icon

Sensitive-volume localization for in vivo NMR using heteronuclear spin-echo pulse sequences.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Heteronuclear spin-echo techniques, which require the application of an inversion pulse on the second heteronucleus, may be applied with inhomogeneous rf coils such as surface coils. There are important applications in vivo including the detection of 13C-labeled and 15N-labeled metabolites in the 1H NMR spectrum. Using a depth pulse scheme for the 1H spin-echo sequence, and particular single or composite 13C pulses, two sensitive volumes are generated by the 1H and the 13C rf coils and signal is only obtained from the region of overlap between the two sensitive volumes. This method of signal localization for in vivo applications can be extended to 1H homonuclear editing and selective polarization-transfer techniques. The off-resonance characteristics of several different composite pulses are explored.

Similar Papers
  • Research Article
  • Citations7

31P/ 1H WALTZ-4 broadband decoupling at 1.5 T: different versions of the composite pulse and consequences when using a surface coil

  • Sep 01, 1998
  • Magnetic Resonance Imaging
  • Stefan Widmaier +4
  • Research Article
  • Citations14

Scalable uniform construction of highly conditional quantum gates

  • Aug 16, 2011
  • Physical Review A
  • Svetoslav S Ivanov +1
  • Research Article
  • Citations28

Cylindrical meanderline radiofrequency coil for intravascular magnetic resonance studies of atherosclerotic plaque

  • Dec 22, 2004
  • Magnetic Resonance in Medicine
  • Christian T Farrar +2
  • Conference Article
  • Citations4

Comparison of Birdcage and Phase Array Coil Using FDTD for the B<inf>1</inf> Homogeneity in High Field MRI

  • Aug 01, 2007
  • J H Seo +3
  • Research Article
  • Citations8

Evaluation of Common RF Coil Setups for MR Imaging at Ultrahigh Magnetic Field: A Numerical Study.

  • Oct 26, 2011
  • ... International Symposium on Applied Sciences in Biomedical and Communication Technologies. International Symposium on Applied Sciences in Biomedical and Communication Technologies
  • Jonathan Lu +5
  • PDF
  • Research Article
  • Citations24

Local Multi-Channel RF Surface Coil versus Body RF Coil Transmission for Cardiac Magnetic Resonance at 3 Tesla: Which Configuration Is Winning the Game?

  • Sep 06, 2016
  • PLoS ONE
  • Oliver Weinberger +10
  • Research Article

SU‐FF‐I‐63: Evaluation of the Turn Variation of Spiral RF Surface Coils for MR Microscopic Imaging and Spectroscopy

  • Jun 01, 2006
  • Medical Physics
  • D Woo +2
  • Research Article
  • Citations23

Spin evolution in a radio frequency field studied through muon spin resonance

  • Nov 07, 2011
  • Journal of Magnetic Resonance
  • Nigel J Clayden +2
  • Conference Article

A CZV-PWM Technique for Three-Level Inverter Current Reconstruction with Neutral Current Sensor

  • Oct 13, 2022
  • Yongpeng Shen +3
  • Research Article
  • Citations24

Measurement of arterial input function of 17O water tracer in rat carotid artery by using a region-defined (REDE) implanted vascular RF coil.

  • Jul 01, 2003
  • Magnetic Resonance Materials in Physics, Biology and Medicine
  • Xiaoliang Zhang +5
  • Research Article
  • Citations41

Phase-modulated rotating-frame spectroscopic localization using an adiabatic plane-rotation pulse and a single surface coil

  • Apr 01, 1991
  • Journal of Magnetic Resonance (1969)
  • Kristy Hendrich +5
  • Supplementary Content
  • Citations1

Multi‐site feasibility and reproducibility study on UTE 3D phosphorous MRSI using novel rosette trajectory (PETALUTE)

  • Jul 22, 2025
  • Magnetic Resonance in Medicine
  • Seyma Alcicek +7
  • Research Article
  • Citations29

Special designed RF-antenna with integrated non-invasive carbon electrodes for simultaneous magnetic resonance imaging and electroencephalography acquisition at 7T

  • Sep 01, 2000
  • Magnetic Resonance Imaging
  • J Van Audekerkea +4
  • PDF
  • Research Article
  • Citations15

Feasibility and repeatability of localized 31P‐MRS four‐angle saturation transfer (FAST) of the human gastrocnemius muscle using a surface coil at 7 T

  • Dec 18, 2015
  • Nmr in Biomedicine
  • Marjeta Tušek Jelenc +5
  • Research Article
  • Citations13

In vivo P-31-MR-spectroscopy of focal hepatic lesions. Effectiveness of tumor detection in clinical practice and experimental studies of surface coil characteristics and localization technique.

  • Jan 01, 1995
  • Investigative Radiology
  • Gisbert Brinkmann +7
Cactus Communications logo