Abstract

A sequential dual-energy subtraction technique for image-guided radiation therapy (IGRT) was developed. Here, we report on a computerized method for creating sequential soft-tissue images and the accuracy of tracking targets on the images obtained, in comparison to conventional fluoroscopic images. Two sets of sequential chest images during respiration of a normal subject were obtained with X-rays of different energy separately with a flat-panel detector (FPD). Sequential soft-tissue images were created from the two sets of sequential images consisting of real-time images and reference template images, respectively. The creation of sequential soft-tissue images consisted of three steps: one-to-one image correspondence of the two sequential images, image registration, and image subtraction in each frame. Motion tracking of lung vessels was then performed by the template-matching technique. For evaluation of the accuracy of motion tracking on the sequential soft-tissue images, the results were compared with those on the original sequential images. Sequential soft-tissue images provided more accurate tracking than the original images (P < 0.01). There was no significant error throughout all frames in the soft-tissue images, whereas the rib shadow introduced a tracking error in the original images. The maximum errors were 4.1 +/- 0.3 mm in the sequential soft-tissue images and 28.1 +/- 20.0 mm in the original images. In conclusion, sequential soft-tissue images were helpful for tracking of a target affected by respiratory motion. Dual-energy subtraction has the potential to improve the accuracy of IGRT without implanted markers.

Similar Papers
  • Research Article
  • Citations1383

Flat-panel cone-beam computed tomography for image-guided radiation therapy

  • Jul 17, 2002
  • International Journal of Radiation Oncology*Biology*Physics
  • David A Jaffray +3
  • Abstract
  • Citations1

Image Guided, Motion-free Patient Body Setup using 3D Volumetric Image Registration of Classified Stable Bony Landmarks

  • Aug 20, 2008
  • International Journal of Radiation Oncology*Biology*Physics
  • G Li +9
  • Conference Article
  • Citations6

&lt;title&gt;Determining a confidence factor for automatic target recognition based on image sequence quality&lt;/title&gt;

  • May 01, 1998
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Gregory J Power +1
  • Research Article
  • Citations18

Detectability of lung nodules using flat panel detector with dual energy subtraction by two shot method: Evaluation by ROC method

  • Mar 26, 2007
  • European Journal of Radiology
  • Hiroyuki Tagashira +4
  • Research Article
  • Citations25

Dynamic dual-energy chest radiography: a potential tool for lung tissue motion monitoring and kinetic study

  • Feb 01, 2011
  • Physics in Medicine & Biology
  • Tong Xu +3
  • Research Article
  • Citations4

Efficiency and reporting confidence analysis of sequential dual-energy subtraction for thoracic x-ray examinations

  • Sep 20, 2019
  • Qatar Medical Journal
  • Mehmet Can Gezer +3
  • Book Chapter
  • Citations27

A Novel Projection Based Approach for Medical Image Registration

  • Jan 01, 2006
  • Ali Khamene +4
  • Conference Article

Linear filtering of spatially invariant image sequences for feature separation under three types of image noise

  • Nov 07, 2002
  • R Olmstead +1
  • Research Article
  • Citations1

Simulation approach for the evaluation of tracking accuracy in radiotherapy: a preliminary study

  • Jul 22, 2012
  • Journal of Radiation Research
  • Rie Tanaka +3
  • Conference Article

Perceptual evaluation of JPEG compression for medical dynamic image sequences

  • Jan 01, 1992
  • James S Whiting +3
  • Conference Article
  • Citations22

6F-3 A Regularized Real-Time Motion Tracking Algorithm Using Dynamic Programming for Ultrasonic Strain Imaging

  • Jan 01, 2006
  • J Jiang +1
  • Research Article
  • Citations80

A technique for respiratory-gated radiotherapy treatment verification with an EPID in cine mode

  • Jul 28, 2005
  • Physics in Medicine & Biology
  • Ross I Berbeco +4
  • Conference Article
  • Citations1

Bone suppression technique for multidirectional dynamic chest radiography: a virtual imaging trial

  • Apr 07, 2023
  • Futa Goshima +4
  • Research Article
  • Citations29

Prospective Evaluation of Dual-Energy Imaging in Patients Undergoing Image Guided Radiation Therapy for Lung Cancer: Initial Clinical Results

  • Apr 18, 2014
  • International Journal of Radiation Oncology*Biology*Physics
  • Tracy Sherertz +7
  • Research Article
  • Citations59

The Use of Fractal Analysis and Photometry to Estimate the Accuracy of Bulbar Redness Grading Scales

  • Apr 01, 2008
  • Investigative Opthalmology &amp; Visual Science
  • Marc M Schulze +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.