• Home
  • Search
  • Set-up error validation with EPID images: Measurements vs Egs_cbct simulation.
  • Open Access IconOpen Access
  • Cite Icon2
  • https://doi.org/10.1016/j.rpor.2019.09.013Copy DOI Icon

Set-up error validation with EPID images: Measurements vs Egs_cbct simulation.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

In this study, the egs_cbct code's ability to replicate an electronic portal imaging device (EPID) is explored. We have investigated head and neck (H&N) setup verification on an Elekta Precise linear accelerator. It is equipped with an electronic portal imaging device (EPID) that can capture a set of projection images over different gantry angles. Cone-beam computed tomography (CBCT) images were reconstructed from projection images of two different setup scenarios. Projections of an Anthropomorphic Rando head phantom were also simulated by using the egs_cbct Monte Carlo code for comparison with the measured projections.Afterwards, CBCT images were reconstructed from this data. Image quality was evaluated against a metric defined as the image acquisition interval (IAI). It determines the number of projection images to be used for CBCT image reconstruction. From this results it was established that phantom shifts could be determined within 2 mm and rotations within one degree accuracy using only 20 projection images (IAI = 10 degrees). Similar results were obtained with the simulated data. In this study it is demonstrated that a head and neck setup can be verified using substantially fewer projection images. Bony landmarks and air cavities could still be observed in the reconstructed Rando head phantom. The egs_cbct code can be used as a tool to investigate setup errors without tedious measurements with an EPID system.

Similar Papers
  • Research Article

Study of image-guided radiotherapy for head and neck cancer based on on-line and off-line CBCT setup verification

  • Jun 25, 2009
  • Zhonghua fangshe yixue yu fanghu zazhi
  • Hongsheng Li +5
  • Research Article
  • Citations38

Detection accuracy of proximal caries by phosphor plate and cone-beam computerized tomography images scanned with different resolutions

  • Jul 30, 2011
  • Clinical Oral Investigations
  • Jun-Ge Cheng +5
  • Conference Article

Registration between MVCT reconstructed from EPID and kVCT

  • Jan 08, 2021
  • Miaomiao Lu +3
  • Research Article

TH‐C‐BRA‐03: GPU‐Based Cone Beam CT Reconstruction

  • Jun 01, 2010
  • Medical Physics
  • X Jia +7
  • Abstract

End of Treatment Cone-Beam CT Correlates with Post-Treatment Follow-up Imaging Response in Head and Neck Squamous Cell Carcinoma

  • Sep 01, 2019
  • International Journal of Radiation Oncology*Biology*Physics
  • W Sumner +4
  • Research Article

Correlation between cone beam computed tomography-guided scheme and setup errors in nasopharyngeal carcinoma

  • Aug 28, 2018
  • Cancer Research and Clinic
  • Yibiao Chen +7
  • Research Article

Clinical applicability of setup margins in radiotherapy based on non-gaussian approach: A multiple-site comparison

  • Dec 29, 2025
  • Asian Journal of Oncology
  • Kalyan Mondal +6
  • Research Article
  • Citations4

Dosimetric assessment of the exposure of radiotherapy patients due to cone-beam CT procedures.

  • Nov 03, 2018
  • Radiation and Environmental Biophysics
  • Mariana Baptista +6
  • Research Article
  • Citations3

Use of electronic portal imaging devices for electron treatment verification

  • Nov 18, 2015
  • Australasian Physical & Engineering Sciences in Medicine
  • T Kairn +3
  • Abstract

Dosimetric Variations Assessed with CBCT for Head and Neck Cancer Radiation Therapy

  • Oct 20, 2018
  • International Journal of Radiation Oncology*Biology*Physics
  • J Xue +5
  • Research Article

SU‐GG‐J‐42: Development of an EPID‐Based Machine and IMRT QA System

  • Jun 01, 2010
  • Medical Physics
  • X Chen +5
  • Research Article
  • Citations1

The planning target volume margins detected by cone-beam CT in head and neck cancer patients treated by image-guided intensity modulated radiotherapy

  • Jul 15, 2011
  • Chinese Journal of Radiation Oncology
  • Jun Liu +4
  • Research Article

Application of CT image registration in the radiotherapy of uterine cervical neoplasms based on 3D Slicer software

  • Aug 28, 2019
  • Cancer Research and Clinic
  • Jia-Bei Xie +5
  • Research Article

Patient dose evaluation for kilovoltage cone beam CT in image-guided radiotherapy

  • Sep 15, 2009
  • Chinese Journal of Radiation Oncology
  • Xiaoxin Liao +2
  • Research Article

Care redesign of pelvic radiotherapy using Design Thinking: An enhanced quality improvement initiative.

  • Oct 10, 2020
  • Journal of Clinical Oncology
  • Cho Hao Francis Ho +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.