• Home
  • Search
  • Shuffled frog leaping algorithm‐based static synchronous compensator for transient stability improvement of a grid‐connected wind farm
  • Cite Icon55
  • https://doi.org/10.1049/iet-rpg.2013.0277Copy DOI Icon

Shuffled frog leaping algorithm‐based static synchronous compensator for transient stability improvement of a grid‐connected wind farm

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The shuffled frog leaping algorithm (SFLA) is presented, to optimally design multiple proportional–integral (PI) controllers of the static synchronous compensator (STATCOM) system with the purpose of improving the transient stability of a grid‐connected wind farm. The control strategy of the STATCOM system depends on a sinusoidal pulse width modulation voltage source converter, which is controlled by the cascaded PI control scheme. The response surface methodology is used to establish a second‐order fitted model of the transient voltage responses at the point of common coupling in terms of PI controllers’ parameters. For realistic responses, a three‐mass drive train model is used for the wind turbine generator system because of its great influence on the dynamic analyses. The SFLA code is built using MATLAB software. The effectiveness of optimised PI‐controlled STATCOM by the SFLA is then compared to that optimised by genetic algorithms technique taking into consideration symmetrical and unsymmetrical fault conditions. The proposed control scheme is applied to a real grid‐connected wind farm system at Hokkaido Island, Japan. The validity of the proposed system is verified by the simulation results, which are performed using PSCAD/EMTDC software environment. With the proposed SFLA‐based STATCOM, the transient stability of a grid‐connected wind farm can be enhanced.

Similar Papers
  • Research Article
  • Citations17

Dynamic compensation of real and reactive power in wind farms using STATCOM

  • Jul 25, 2016
  • Perspectives in Science
  • Shahzad Ahsan +1
  • Conference Article
  • Citations19

Control strategy study of STATCOM based on cascaded PWM H-bridge converter with delta configuration

  • Jun 01, 2012
  • Sixing Du +3
  • Research Article
  • Citations25

Coordinated Control of Reactive Power between STATCOMs and Wind Farms for PCC Voltage Regulation

  • Sep 20, 2013
  • Journal of Power Electronics
  • Thanh Hai Nguyen +3
  • Research Article
  • Citations19

A Comparison Study of Reactive Power Control Strategies in Wind Farms with SVC and STATCOM

  • Dec 01, 2018
  • International Journal of Electrical and Computer Engineering (IJECE)
  • Nazha Cherkaoui +4
  • Research Article
  • Citations9

Dynamic performance improvement of wind farms equipped with three SCIG generators using STATCOM

  • Dec 19, 2014
  • Journal of Energy in Southern Africa
  • Othman Hasnaoui +1
  • Conference Article
  • Citations14

Power quality and transient stability improvement of wind farm with fixed-speed induction generators using a STATCOM

  • Oct 01, 2010
  • Guizhen Tian +2
  • Conference Article
  • Citations16

Simplified Active and Reactive Power Control of Doubly Fed Induction Generator and the Simulation with STATCOM

  • Feb 01, 2009
  • Liu Chun +6
  • Conference Article
  • Citations5

Study on Different Modes of Reactive Power Compensation and Reactive Power Coordinated Control for Wind Farm

  • Jul 01, 2020
  • Chunsun Tian +5
  • Research Article
  • Citations13

Transient Stability Improvement of a FSIG Based Grid Connected wind Farm with the help of a SVC and aSTATCOM: A Comparison

  • Jan 01, 2012
  • International Journal of Computer and Electrical Engineering
  • Rajiv Singh +2
  • Research Article
  • Citations24

Small-signal instability and supplementary coordinated damping-control of LCC-HVDC system with STATCOM under weak AC grid conditions

  • Jul 13, 2018
  • International Journal of Electrical Power & Energy Systems
  • Chunyi Guo +2
  • Research Article
  • Citations4

STATCOM Parameters Optimization Using Multi-Objective LAPO for Enhancing the Stability of Combined Wind Farm

  • Dec 02, 2020
  • Electric Power Components and Systems
  • Ahmed Rashad +3
  • Research Article

Design of Multicarrier Pulse Width Modulation based Cascaded Multilevel Inverter for STATCOM using Bats Echolocation Controller

  • Jan 01, 2012
  • Automation and Autonomous Systems
  • G Kumaravel +1
  • Conference Article
  • Citations6

Image Watermarking Scheme Based on Shuffled Frog Leaping Algorithm

  • Dec 01, 2008
  • Ziqiang Wang +1
  • Conference Article
  • Citations2

Stability enhancement of a grid connected wind farm by using STATCOM

  • Nov 01, 2015
  • M R I Sheikh +2
  • Conference Article

Comparative analysis of 6, 12 and 48 pulse T-STATCOM

  • Nov 01, 2016
  • Swapnil D Mahajan +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.