• Home
  • Search
  • Smart scanning for two: [18F]FDG dose optimization for pregnant patients using LAFOV PET/CT technology.
  • https://doi.org/10.1186/s40658-026-00855-7Copy DOI Icon

Smart scanning for two: [18F]FDG dose optimization for pregnant patients using LAFOV PET/CT technology.

Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

This study aimed to evaluate the image quality-dose trade-off in pregnant patients imaged with long-axial field-of-view [18F]FDG PET/CT and to identify the most predictive body composition metric for image quality to develop a pregnancy-tailored dosage model. Patients imaged with [18F]FDG PET/CT according to local pregnancy protocols were included in this study. Using raw PET data, images of various degrees of image quality were reconstructed. Acceptable image quality was identified using signal-to-noise ratio (SNR) in the liver and Likert scores. The minimum required scan statistics was modelled based on SNR and patient body composition. F-tests were used to find the best-fitting model parameter out of weight, weight-to-height-ratio, body-mass-index, and body surface area (BSA). Foetal dose was estimated with PET conversion factors and size-specific CT dose index values. Eleven patients were included in image quality analysis and dosage model optimization. SNR strongly correlated with Likert scores (R² = 0.80), with 10.72 SNR indicating acceptable image quality. BSA best predicted image quality (R² = 0.85), outperforming weight (R² = 0.78), weight-to-height ratio (R² = 0.63), and body mass index (R² = 0.38). The proposed dosage model reduces activity by 41-96% compared to current local pregnancy and adult protocols, resulting in estimated foetal radiation doses of 0.066 mGy (PET) and 0.31 mGy (CT). BSA accurately predicted [18F]FDG PET/CT image quality in pregnant patients. The proposed dosage regimen allows significant dose reduction and can be used as a foundation for the development of pregnancy dosage protocols.

Similar Papers
  • Research Article

Monte Carlo study on fetal dose assessment for carbon beam craniospinal irradiation during pregnancy.

  • Feb 27, 2026
  • Medical physics
  • Ji Won Choi +8
  • Research Article

Fetal Dose in CT Scans During Pregnancy

  • Apr 25, 2025
  • Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi
  • Ümit Kara
  • Research Article

SU-GG-I-83: Online Software for the Evaluation of Fetal Doses in Diagnostic Radiology

  • Jun 01, 2010
  • Medical Physics
  • P Costa +1
  • Discussion
  • Citations1

Reply

  • Dec 01, 2005
  • American Journal of Obstetrics and Gynecology
  • Nora M Doyle +1
  • Research Article
  • Citations4

Evaluation of Compressed SENSE on Image Quality and Reduction of MRI Acquisition Time: A Clinical Validation Study

  • Aug 28, 2023
  • Academic Radiology
  • Pohchoo Seow +13
  • Research Article
  • Citations82

Fetal dose estimates for radiotherapy of brain tumors during pregnancy

  • Jun 01, 1995
  • International Journal of Radiation Oncology*Biology*Physics
  • Penny K Sneed +4
  • Research Article
  • Citations4

Multi-band whole-body diffusion-weighted imaging with inversion recovery fat saturation: Effects of respiratory compensation

  • Jan 01, 2021
  • European Journal of Radiology Open
  • Solveig Kärk Abildtrup Larsen +2
  • Research Article

Identification of image quality degradation factors in abdominal free-breathing dynamic contrast-enhanced magnetic resonance imaging (MRI).

  • Sep 01, 2025
  • Clinical radiology
  • Y Noda +9
  • Research Article

MO-D-T-617-05: Fetal Doses Measurements for Helical Tomotherapy

  • May 26, 2005
  • Medical Physics
  • Divyakant Desai +3
  • Research Article
  • Citations10

Development and validation of the low-cost pregnant female physical phantom for fetal dosimetry in MV photon radiotherapy.

  • Dec 27, 2023
  • Journal of Applied Clinical Medical Physics
  • Vjekoslav Kopačin +8
  • Research Article

Computed tomography radiation dose optimization for the diagnosis of acute rib fractures in infants investigated for suspected physical abuse: An experimental animal study.

  • Nov 01, 2025
  • Child abuse & neglect
  • Nasser M Alzahrani +4
  • Dissertation

Impact of time-of-flight technology on PET/CT image quality and SUV quantitation

  • Jan 01, 2012
  • Yu-Ching Lau
  • PDF
  • Research Article
  • Citations22

A qualitative and quantitative analysis of radiation dose and image quality of computed tomography images using adaptive statistical iterative reconstruction

  • May 01, 2016
  • Journal of Applied Clinical Medical Physics
  • Fahad Ahmed Hussain +4
  • PDF
  • Research Article
  • Citations8

Fetal dose assessment in a pregnant patient with brain tumor: A comparative study of proton PBS and 3DCRT/VMAT radiation therapy techniques.

  • Jun 17, 2024
  • Journal of applied clinical medical physics
  • Robabeh Rahimi +11
  • PDF
  • Research Article

The analysis of the subjective image quality of a dental radiogram obtained with a digital and film detector

  • Nov 07, 2020
  • Radiološke tehnologije
  • Ermina Sadiković +5
Cactus Communications logo