• Home
  • Search
  • Snapshot whole-brain T1 relaxometry using steady-state prepared spiral multislice variable flip angle imaging.
  • Cite Icon3
  • https://doi.org/10.1002/mrm.26746Copy DOI Icon

Snapshot whole-brain T1 relaxometry using steady-state prepared spiral multislice variable flip angle imaging.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Variable flip angle (VFA) imaging is widely used for whole-brain T1 quantification. Because of the requirement to acquire at least two sets of MR images at different flip angles, VFA relaxometry is relatively slow. Here, whole-brain VFA T1 mapping at 1.5 T is accelerated by using efficient spiral non-Cartesian imaging METHODS: To quantify T1 in the human brain, radiofrequency spoiled gradient-echo imaging is performed at two optimized flip angles using an interleaved 2D multislice sequence with high spoiling efficiency. The acquisitions are accelerated by using a spiral trajectory with 10 interleaves combined with a dedicated magnetization preparation to ensure steady-state conditions in minimal time. The investigated MR scan protocol allowed the acquisition of whole-brain T1 maps at a clinically relevant resolution in only 40 s (0.7 s per slice) with high reproducibility. White and gray matter T1 peaks clearly could be delineated by calculation of whole-brain T1 histograms, and the delivered T1 values showed good agreement with the reference method in selected regions of interest. Due to the use of a fast spiral k-space trajectory, whole-brain VFA T1 mapping could be accelerated by an order of magnitude compared to conventional Cartesian sampling. Magn Reson Med 79:856-866, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

Similar Papers
  • Research Article
  • Citations110

Accuracy, repeatability, and interplatform reproducibility of T1 quantification methods used for DCE-MRI: Results from a multicenter phantom study.

  • Sep 14, 2017
  • Magnetic Resonance in Medicine
  • Octavia Bane +22
  • Research Article
  • Citations20

Accuracy, precision, and reproducibility of myocardial T1 mapping: A comparison of four T1 estimation algorithms for modified look-locker inversion recovery (MOLLI).

  • Dec 04, 2016
  • Magnetic Resonance in Medicine
  • Jiaxin Shao +4
  • Research Article
  • Citations172

Optimal radiofrequency and gradient spoiling for improved accuracy of T1 and B1 measurements using fast steady‐state techniques

  • May 21, 2010
  • Magnetic Resonance in Medicine
  • Vasily L Yarnykh
  • Research Article
  • Citations24

Selective in vivo bone imaging with long-T2 suppressed PETRA MRI.

  • Feb 24, 2016
  • Magnetic Resonance in Medicine
  • Cheng Li +4
  • Conference Article

Rapid 3D Whole-Brain High-Resolution T1 Quantification: Accelerating Standard Inversion Recovery with Stack-of-Spirals FLASH Acquisition

  • Sep 16, 2025
  • Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
  • Zhen Hu +2
  • Research Article
  • Citations2

Effects of T2 * on accuracy and precision of dynamic T1 measurements using the single reference variable flip angle method: a simulation study.

  • Feb 15, 2022
  • Medical Physics
  • Michael A Malmberg +2
  • Research Article
  • Citations11

Propagation of error from parameter constraints in quantitative MRI: Example application of multiple spin echo T2 mapping

  • Apr 20, 2017
  • Magnetic Resonance in Medicine
  • Christopher L Lankford +1
  • PDF
  • Research Article
  • Citations21

Creatine kinase rate constant in the human heart measured with 3D‐localization at 7 tesla

  • Aug 31, 2016
  • Magnetic Resonance in Medicine
  • William T Clarke +3
  • Research Article
  • Citations80

Accurate T1 mapping of short T2 tissues using a three-dimensional ultrashort echo time cones actual flip angle imaging-variable repetition time (3D UTE-Cones AFI-VTR) method.

  • Jan 03, 2018
  • Magnetic Resonance in Medicine
  • Ya‐Jun Ma +7
  • Research Article
  • Citations2

Comparative Study Between Variable Flip Angle and Modified Look-Locker Inversion Recovery for Evaluating Renal Interstitial Fibrosis.

  • Sep 16, 2024
  • Journal of magnetic resonance imaging : JMRI
  • Chenchen Hua +8
  • Research Article

Inter- and intra-rater reproducibility of quantitative T1 measurement using semiautomatic region of interest placement in myometrium

  • Jan 26, 2024
  • PLOS ONE
  • Sadahiro Nakagawa +8
  • Research Article
  • Citations31

In vivo quantitative whole-brain T1 rho MRI of multiple sclerosis.

  • May 30, 2015
  • Journal of Magnetic Resonance Imaging
  • Jay V Gonyea +7
  • Research Article
  • Citations19

Balanced SSFP transient imaging using variable flip angles for a predefined signal profile

  • Oct 26, 2010
  • Magnetic Resonance in Medicine
  • Pauline W Worters +1
  • Research Article
  • Citations4

Comparison of DCE-MRI parametric mapping using MP2RAGE and variable flip angle T1 mapping

  • Jul 06, 2020
  • Magnetic Resonance Imaging
  • Robert V Bergen +2
  • Research Article
  • Citations51

Simultaneous variable flip angle–actual flip angle imaging method for improved accuracy and precision of three‐dimensional T1 and B1 measurements

  • Dec 02, 2011
  • Magnetic Resonance in Medicine
  • Samuel A Hurley +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.