  • Soft-tissue lesion and microcalcification detectability in cone-beam breast CT: cascaded system analysis.
  • https://doi.org/10.1117/1.jmi.12.6.063501Copy DOI Icon

Soft-tissue lesion and microcalcification detectability in cone-beam breast CT: cascaded system analysis.

Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

We aim to investigate the performance of dedicated breast computed tomography (CT) for the detection of soft-tissue lesions and compare it to the detection of microcalcification clusters using cascaded systems analysis, with the intent of identifying which lesion type should be used for system optimization. Signal and noise were propagated through the imaging chain using a cascaded systems model to obtain the modulation transfer function and noise power spectrum. Two imaging tasks were considered: a soft-tissue mass lesion modeled as a disk of 4mm diameter and a cluster of microcalcifications modeled as calcium carbonate spheres of diameter. Detectability indices using three numerical observer models were obtained for various scintillator thicknesses and acquisition conditions at a fixed 4.5 mGy mean glandular dose. Detectability index trends are reversed between soft-tissue lesion and microcalcification cluster for the range of X-ray tube voltages and filtrations studied, indicating a potential need for compromise. However, for each of the 150 combinations studied (6kV settings Cu filter thicknesses CsI:Tl scintillator thicknesses) and for each of the three numerical observer models, the detectability index for soft-tissue lesions always exceeded the microcalcification cluster. When the lesion type is unknown, such as during breast cancer screening, it is more appropriate to optimize the system parameters for the task of detecting a microcalcification cluster, as the detectability index for the soft-tissue lesion exceeded that for the microcalcification cluster for all conditions investigated.

Similar Papers
  • Conference Article
  • Citations10

NEQ and task in dual-energy imaging: from cascaded systems analysis to human observer performance

  • Mar 06, 2008
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Samuel Richard +2
  • PDF
  • Research Article
  • Citations56

Cascaded systems analysis of photon counting detectors.

  • Oct 01, 2014
  • Medical physics
  • J Xu +8
  • Research Article
  • Citations77

Visibility of microcalcification in cone beam breast CT: effects of X-ray tube voltage and radiation dose.

  • Jun 26, 2007
  • Medical physics
  • Chao-Jen Lai +9
  • PDF
  • Research Article
  • Citations5

Profil clinique et évolutif des lésions de la peau et des parties molles chez les diabétiques en 2017 à la salle de pansement du Centre Marc Sankale de Dakar

  • Apr 29, 2019
  • The Pan African Medical Journal
  • Diallo Ibrahima Mané +7
  • Research Article
  • Citations9

Computer Aided Detection of Clustered Microcalcification: A Survey

  • Jan 10, 2019
  • Current Medical Imaging Formerly Current Medical Imaging Reviews
  • M.N Arun Kumar +2
  • Conference Article
  • Citations4

A relevance vector machine technique for the automatic detection of clustered microcalcifications (Honorable Mention Poster Award)

  • Apr 29, 2005
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Liyang Wei +2
  • Book Chapter
  • Citations12

Self-adversarial Learning for Detection of Clustered Microcalcifications in Mammograms

  • Jan 01, 2021
  • Xi Ouyang +8
  • PDF
  • Research Article
  • Citations5

Three-Dimensional Computer-Aided Detection of Microcalcification Clusters in Digital Breast Tomosynthesis

  • Jan 01, 2016
  • BioMed Research International
  • Ji-Wook Jeong +5
  • Research Article
  • Citations2

Theoretical Framework for the Dual-Energy Cone-Beam CT Noise-Power Spectrum, NEQ, and Tasked-Based Detectability Index.

  • Feb 23, 2012
  • Proceedings of SPIE--the International Society for Optical Engineering
  • G J Gang +4
  • Conference Article
  • Citations16

Automated detection of microcalcifications in mammograms through application of image pixel remapping and statistical filter

  • Jun 12, 1998
  • M Wilson +4
  • Research Article
  • Citations66

Analysis of methods for reducing false positives in the automated detection of clustered microcalcifications in mammograms.

  • Aug 01, 1998
  • Medical physics
  • Rufus H Nagel +3
  • Research Article
  • Citations128

Analysis of Fourier‐domain task‐based detectability index in tomosynthesis and cone‐beam CT in relation to human observer performance

  • Mar 08, 2011
  • Medical Physics
  • Grace J Gang +6
  • Research Article
  • Citations1

Intra- and inter-scanner CT variability and their impact on diagnostic tasks.

  • Apr 08, 2025
  • Proceedings of SPIE--the International Society for Optical Engineering
  • Isabel Montero +3
  • Conference Article
  • Citations5

3D task-based performance assessment metrics for optimization of performance and dose in breast tomosynthesis

  • Mar 03, 2011
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • S Richard +1
  • Research Article
  • Citations10

Evaluation and treatment of soft tissue lesions of the ankle and forefoot using the Cyriax approach: a case report.

  • Aug 01, 1982
  • Physical therapy
  • Russell M Woodman +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.