Solid-state fluoroscopic imager for high-resolution angiography: parallel-cascaded linear systems analysis.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Cascaded linear systems based modeling techniques have been used in the past to predict important system parameters that have a direct impact on image quality. Such models are also useful in optimizing system parameters to improve image quality. In this work, detailed analysis of a solid-state fluoroscopic imaging system intended for high-resolution angiography is presented with the use of such a model. The imaging system analyzed through this model uses four 8 x 8 cm three-side buttable interlined charge-coupled devices (CCDs) specifically designed for high-resolution angiography and tiled in a seamless fashion to achieve a field of view (FOV) of 16 x 16 cm. Larger FOVs can be achieved by tiling more CCDs in a similar manner. The system employs a CsI:Tl scintillator coupled to the CCDs by straight (nontapering) fiberoptics and can potentially be operated in 78, 156, or 234 microm pixel pitch modes. The system parameters analyzed through this model include presampling modulation transfer function, noise power spectrum, and detective quantum efficiency (DQE). The results of the simulations performed indicate that DQE(0) in excess of 0.6 is achievable, with the imager operating at 156 microm pixel pitch, 30 frames/s, and employing a 450-microm-thick CsI:Tl scintillator, even at a low fluoroscopic exposure rate of 1 microR/frame. Further, at a nominal fluoroscopic exposure rate of 2.5 microR/frame there was no noticeable degradation of the DQE even at the 78 microm pixel pitch mode suggesting that it is feasible to perform high-resolution angiography hitherto unattainable in clinical practice.

Similar Papers
  • Research Article
  • Citations18

Theoretical analysis of high-resolution digital mammography

  • May 31, 2006
  • Physics in Medicine & Biology
  • Sankararaman Suryanarayanan +3
  • Conference Article
  • Citations3

A novel x-ray detector design with higher DQE and reduced aliasing: Theoretical analysis of x-ray reabsoprtion in detector converter material

  • Mar 22, 2016
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Tomi Nano +3
  • Conference Article
  • Citations49

DQE of direct and indirect digital radiography systems

  • Jun 28, 2001
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Ehsan Samei +3
  • Research Article
  • Citations2

Performance of Dual-Layer Flat-Panel Detectors.

  • Jul 28, 2025
  • Diagnostics (Basel, Switzerland)
  • Dong Sik Kim +1
  • PDF
  • Research Article
  • Citations56

Cascaded systems analysis of photon counting detectors.

  • Oct 01, 2014
  • Medical physics
  • J Xu +8
  • Conference Article
  • Citations2

<title>Compton scatter in frequency space: a theoretical study</title>

  • May 02, 2002
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Jingwu Yao +1
  • Research Article
  • Citations4

Use of local noise power spectrum and wavelet analysis in quantitative image quality assurance for EPIDs.

  • Aug 04, 2016
  • Medical Physics
  • Soyoung Lee +4
  • Research Article

SU‐E‐I‐62: Assessing Radiation Dose Reduction and CT Image Optimization Through the Measurement and Analysis of the Detector Quantum Efficiency (DQE) of CT Images Using Different Beam Hardening Filters

  • May 29, 2014
  • Medical Physics
  • J Collier +2
  • Research Article

Technical Note: Impact on detective quantum efficiency of edge angle determination method by International Electrotechnical Commission methodology for cardiac x-ray image detectors.

  • Jul 02, 2015
  • Medical physics
  • Amber J Gislason‐Lee +4
  • Research Article
  • Citations1

WE‐D‐I‐611‐03: Non‐Fourier Concepts in Image Quality

  • May 26, 2005
  • Medical Physics
  • K Myers +4
  • Conference Article
  • Citations2

<title>Assessment of objective image quality in digital radiography: noninvasive determination of the detective quantum efficiency</title>

  • Apr 11, 1996
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Karl-Friedrich Kamm +2
  • Research Article
  • Citations62

Effects of x-ray spectra on the DQE of a computed radiography system

  • Feb 01, 2001
  • Medical Physics
  • Kenneth A Fetterly +1
  • Research Article
  • Citations16

Digital x-ray imaging using amorphous selenium: reduction of aliasing.

  • Oct 28, 1998
  • Medical Physics
  • W G Ji +2
  • Research Article

Performance Characteristics of a CdTe-Based Digital Gamma Imaging System with a 75Se Radioisotope

  • Jun 01, 2008
  • Journal of Nuclear Science and Technology
  • H S Cho +6
  • Research Article
  • Citations213

A spatial‐frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems

  • Mar 01, 1994
  • Medical Physics
  • I A Cunningham +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.