• Home
  • Search
  • Source Nuclide Density First-Order and Second-Order Sensitivities in Monte Carlo Codes
  • Open Access IconOpen Access
  • https://doi.org/10.1080/00295639.2022.2161279Copy DOI Icon

Source Nuclide Density First-Order and Second-Order Sensitivities in Monte Carlo Codes

Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

Application of perturbation capabilities for density sensitivities in Monte Carlo radiation transport codes has been limited because changing source nuclide densities or source material densities changes the intrinsic source, and in most Monte Carlo codes, the user-input source is independent of the user-input materials. The perturbation capability then has no way of accounting for changes in the intrinsic source. This paper derives the sensitivity of a response with respect to a source nuclide density in terms of a portion due to the transport operator and a portion due to the source rate density. The Monte Carlo perturbation method computes the portion due to the transport operator, and the portion due to the source rate density is computed in postprocessing using parameters from the precomputed intrinsic source calculation. This paper derives first- and second-order sensitivities. The equations require the response to be separated by contribution from each of the sources modeled. A test problem containing several (α,n) and spontaneous fission neutron sources verifies the method.

Similar Papers
  • Research Article
  • Citations29

Physical models, cross sections, and numerical approximations used inMCNPandGEANT4Monte Carlo codes for photon and electron absorbed fraction calculation

  • Oct 13, 2009
  • Medical Physics
  • Hélio Yoriyaz +5
  • Conference Article
  • Citations1

Parallelization of a radiation transport simulation code on the BBN TC2000 parallel computer

  • Oct 01, 1990
  • William Celmaster +1
  • Research Article
  • Citations3

FLUKAVAL – A validation framework for the FLUKA radiation transport Monte Carlo code

  • Jan 01, 2023
  • EPJ Web of Conferences
  • Markus Widorski +3
  • Research Article
  • Citations10

Photoneutron production in heavy water reactor fuel lattice from accelerator-driven bremsstrahlung

  • Jan 23, 2021
  • Annals of Nuclear Energy
  • Douglas A Fynan +4
  • Conference Article

Acceleration of a Monte Carlo radiation transport code

  • Jan 01, 1996
  • AIP conference proceedings
  • Reuben D Hochstedler +1
  • Conference Article
  • Citations4

On learning particle distributions in the 1D implicit Monte Carlo simulations of radiation transport

  • Aug 21, 2020
  • Anna Matsekh +3
  • Research Article
  • Citations23

Comparison of normal tissue dose calculation methods for epidemiological studies of radiotherapy patients

  • May 10, 2018
  • Journal of Radiological Protection
  • Matthew M Mille +4
  • Research Article
  • Citations2

Study of the response of a lithium yttrium borate scintillator based neutron rem counter by Monte Carlo radiation transport simulations

  • Sep 16, 2015
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • C Sunil +4
  • PDF
  • Research Article
  • Citations7

A new ground level neutron monitor for space weather assessment

  • Mar 26, 2024
  • Scientific Reports
  • Michael D Aspinall +9
  • Research Article
  • Citations1

EFFECT OF WINDOWS AND DOORS ON THE GAMMA SHIELDING FACTOR FOR TYPICAL HOUSES IN BRAZIL

  • Mar 01, 2007
  • Health Physics
  • I C P Salinas +2
  • Research Article
  • Citations64

Monte Carlo calculations of AAPM Task Group Report No. 43 dosimetry parameters for the MED3631-A/M125I source.

  • Apr 01, 2001
  • Medical Physics
  • Mark J Rivard
  • Abstract

64: DNA damage, protein expression and migration of melanoma cells irradiated with proton beam

  • Feb 01, 2014
  • Radiotherapy and Oncology
  • M Elas +11
  • Research Article
  • Citations18

Gxsview: Geometry and cross section viewer for calculating radiation transport

  • Feb 19, 2021
  • SoftwareX
  • Seiki Ohnishi
  • Single Report
  • Citations1

Cost-optimized Automated Variance Reduction for Highly Angle-dependent Radiation Transport Analyses [Dissertation

  • Mar 06, 2023
  • Joel Kulesza
  • Research Article
  • Citations7

Application of ADVANTG variance reduction parameters with MCNP6 at ESS

  • Jan 01, 2020
  • Journal of Neutron Research
  • Thomas M Miller +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.