• Home
  • Search
  • Spectral computed tomography thermometry for thermal ablation: applicability and needle artifact reduction.
  • https://doi.org/10.1016/j.ejmp.2025.105093Copy DOI Icon

Spectral computed tomography thermometry for thermal ablation: applicability and needle artifact reduction.

  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

Effective thermal ablation of liver tumors requires precise monitoring of the ablation zone. Computed tomography (CT) thermometry can non-invasively monitor lethal temperatures but suffers from metal artifacts caused by ablation equipment. This study assesses spectral CT thermometry's applicability during microwave ablation, comparing the reproducibility, precision, and accuracy of attenuation-based versus physical density-based thermometry. Furthermore, it identifies optimal metal artifact reduction (MAR) methods: O-MAR, deep learning-MAR, spectral CT, and combinations thereof. Four gel phantoms embedded with temperature sensors underwent a 10- minute, 60W microwave ablation imaged by dual-layer spectral CT scanner in 23 scans over time. For each scan attenuation-based and physical density-based temperature maps were reconstructed. Attenuation-based and physical density-based thermometry models were tested for reproducibility over three repetitions; a fourth repetition focused on accuracy. MAR techniques were applied to one repetition to evaluate temperature precision in artifact-corrupted slices. The correlation between CT value and temperature was highly linear with an R-squared value exceeding 96%. Model parameters for attenuation-based and physical density-based thermometry were -0.38 HU/°C and 0.00039°C-1, with coefficients of variation of 2.3% and 6.7%, respectively. Physical density maps improved temperature precision in presence of needle artifacts by 73% compared to attenuation images. O-MAR improved temperature precision with 49% compared to no MAR. Attenuation-based thermometry yielded narrower Bland-Altman limits-of-agreement (-7.7°C to 5.3°C) than physical density-based thermometry. Spectral physical density-based CT thermometry at 150keV, utilized alongside O-MAR, enhances temperature precision in presence of metal artifacts and achieves reproducible temperature measurements with high accuracy.

Similar Papers
  • Conference Article
  • Citations5

Spectral CT metal artifact reduction with an optimization-based reconstruction algorithm

  • Mar 09, 2017
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Taly Gilat Schmidt +2
  • Research Article
  • Citations1

The Clinical Value of the MAR + Metal Artifact Reduction Algorithm for Postoperative Assessment of Lumbar Internal Fixation.

  • Jan 27, 2025
  • Journal of computer assisted tomography
  • Jiayi Fang +4
  • Research Article
  • Citations10

Metal artifact reduction using mono-energy images combined with metal artifact reduction software in spectral computed tomography: a study on phantoms.

  • Jul 01, 2020
  • Quantitative Imaging in Medicine and Surgery
  • Xiaoli Sun +4
  • Research Article
  • Citations37

Visual grading evaluation of commercially available metal artefact reduction techniques in hip prosthesis computed tomography.

  • Apr 28, 2016
  • The British journal of radiology
  • Karin M Andersson +8
  • Research Article
  • Citations7

Comparison of metal artifact reduction techniques in magnetic resonance imaging of carbon-reinforced PEEK and titanium spinal implants.

  • Jul 06, 2021
  • Acta Radiologica
  • Georg Osterhoff +6
  • Research Article
  • Citations85

An experimental survey of metal artefact reduction in computed tomography

  • May 01, 2013
  • Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics
  • Andre Mouton +4
  • Conference Article
  • Citations1

Metal Artifact Reduction by Using Dual-Energy Raw Data Constraint Learning

  • Oct 23, 2021
  • Fanning Kong +4
  • Research Article
  • Citations15

Metal artifact reduction techniques for single energy CT and dual-energy CT with various metal materials

  • Jul 01, 2019
  • BJR Open
  • Daisuke Kawahara +15
  • PDF
  • Research Article
  • Citations13

An additional tilted‐scan‐based CT metal‐artifact‐reduction method for radiation therapy planning

  • Dec 31, 2018
  • Journal of Applied Clinical Medical Physics
  • Changhwan Kim +7
  • Research Article

TU‐E‐141‐06: Estimation of Dose Distributions with the Dental Artifact Correction in Radiation Treatment Plans for Head‐And‐Neck Cancers

  • Jun 01, 2013
  • Medical Physics
  • M Lee +5
  • Research Article
  • Citations3

Improvement of CT Imaging with a Metal Artifact Reduction Technique for Radiation Treatment Planning-Fundamental Study of Structure Delineation and Dose Calculation

  • Jan 01, 2018
  • Nihon Hoshasen Gijutsu Gakkai zasshi
  • Takuya Nishitani +5
  • Research Article
  • Citations156

Metal artifacts in computed tomography for radiation therapy planning: dosimetric effects and impact of metal artifact reduction

  • Mar 21, 2017
  • Physics in Medicine & Biology
  • Drosoula Giantsoudi +7
  • Research Article
  • Citations167

Metal artifact reduction techniques in musculoskeletal CT-imaging

  • Aug 12, 2018
  • European Journal of Radiology
  • R.H.H Wellenberg +5
  • Research Article

Orthopaedic application of computed tomography metal artifact reduction

  • Apr 08, 2018
  • Chinese journal of experimental surgery
  • Kesong Zhang +5
  • PDF
  • Research Article
  • Citations14

Metal Artifact Reduction in Spectral X-ray CT Using Spectral Deep Learning

  • Mar 17, 2022
  • Journal of Imaging
  • Matteo Busi +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.