To calculate the percentage depth dose of any irregular shape electron beam using modified lateral build-up-ratio method. Percentage depth dose (PDD) curves were measured using 6, 9, 12, and 15MeV electron beam energies for applicator cone sizes of 6×6, 10×10, 14×14, and 14×14cm2 . Circular cutouts for each cone were prepared from 2.0cm diameter to the maximum possible size for each cone. In addition, three irregular cutouts were prepared. The scanning was done using a water tank and two diodes - one for the signal and the other a stationary reference outside the tank. The water surface was determined by scanning the signal diode slowly from water to air and by noting the sharp change of the percentage depth dose curve at the water/air interface. The lateral build-up-ratio (LBR) for each circular cutout was calculated from the measured PDD curve using the open field of the 14×14 cm2 cone as the reference field. Using the LBR values and the radius of the circular cutouts, the corresponding lateral spread parameter (sigma) of the electron shower was calculated. Unlike the commonly accepted assumption that sigma is independent of cutout size, it is shown that the sigma value increases linearly with circular cutout size. Using this characteristic of sigma, the PDD curves of irregularly shaped cutouts were calculated. Finally, the calculated PDD curves were compared with measured PDD curves. In this research, it is shown that sigma increases with cutout size. For radius of circular cutout sizes up to the equilibrium range of the electron beam, the increase of sigma with the cutout size is linear. The percentage difference of the calculated PDD from the measured PDD for irregularly shaped cutouts was under 1.0%. Similar Result was obtained for four electron beam energies (6, 9, 12, and 15MeV).

Similar Papers
  • PDF
  • Research Article
  • Citations1

An iterative algorithm to estimate the energy spectrum of an electron beam from PDD curves

  • Jan 01, 2024
  • Journal of Physics: Conference Series
  • Enrico Nichelatti +3
  • PDF
  • Research Article
  • Citations4

Dosimetric Characteristics of 6 MV Medical Linac at BAEC

  • Jan 01, 2021
  • International Journal of Medical Physics, Clinical Engineering and Radiation Oncology
  • Sudeb Kumar Roy +6
  • Research Article

Film measurements of kilovoltage x-ray percentage depth doses for different energies and field sizes.

  • May 27, 2025
  • The British journal of radiology
  • Tze Yee Lim +4
  • Research Article

Electron spectra measurements in linear accelerators via neural network reconstruction from percentage depth dose (PDD) data.

  • Feb 01, 2026
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
  • Jorge Torres-Díaz +4
  • Research Article
  • Citations1

The Study of Field Equivalence Determined by the Modeled Percentage Depth Dose in Electron Beam Radiation Therapy.

  • Jan 01, 2021
  • BioMed Research International
  • You-Guo Ma +3
  • Abstract

Photon Activation Therapy using Robotic Delivery of Microindexed Beams of kV Radiation

  • Oct 03, 2009
  • International Journal of Radiation Oncology*Biology*Physics
  • M Carol
  • Research Article
  • Citations45

Derivation of electron and photon energy spectra from electron beamcentral axis depth dose curves

  • Apr 17, 2001
  • Physics in Medicine & Biology
  • Jun Deng +4
  • Research Article

Empirical modeling of the percent depth dose for megavoltage photon beams

  • Jan 06, 2022
  • PLoS ONE
  • Xiao-Jun Li +4
  • Abstract
  • Citations2

P100] Calculations of dosimetric parameters from depth dose curve of electron beams, using radiophotoluminescent and thermoluminescent dosimeters

  • Aug 01, 2018
  • Physica Medica
  • Abdel-Hai Benali +2
  • PDF
  • Research Article
  • Citations2

Evaluation of the water-equivalent characteristics of the SP34 plastic phantom for film dosimetry in a clinical linear accelerator.

  • Oct 23, 2023
  • PLoS ONE
  • Kyo-Tae Kim +6
  • Research Article
  • Citations36

Characterization of a microDiamond detector in high-dose-per-pulse electron beams for intra operative radiation therapy

  • Jul 07, 2015
  • Physica Medica
  • C Di Venanzio +9
  • Research Article
  • Citations23

Comprehensive quality assurance phantom for the small animal radiation research platform (SARRP)

  • May 08, 2015
  • Physica Medica
  • M Jermoumi +7
  • PDF
  • Research Article
  • Citations3

Attenuation measurements show that the presence of a TachoSil surgical patch will not compromise target irradiation in intra-operative electron radiation therapy or high-dose-rate brachytherapy

  • Jan 09, 2015
  • Radiation Oncology (London, England)
  • Sandra Sarmento +8
  • Research Article
  • Citations18

The influence of mammographic X-ray spectra on absorbed energy distribution in breast: Monte Carlo simulation studies

  • Jun 08, 2004
  • Radiation Measurements
  • H Delis +3
  • Research Article

Development and dosimetric evaluation of a modulated intraoperative radiotherapy (mIORT) system using the Zeiss intrabeam device

  • Mar 25, 2025
  • Physics in Medicine & Biology
  • Xavier Jones +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.