• Home
  • Search
  • SU‐GG‐J‐185: Towards in Vivo Dose Validation Using Real‐Time Physiologically Constrained Deformable Image Registration
  • https://doi.org/10.1118/1.2961734Copy DOI Icon

SU‐GG‐J‐185: Towards in Vivo Dose Validation Using Real‐Time Physiologically Constrained Deformable Image Registration

Show More
  • Abstract
  • Literature Map
  • Similar Papers
Abstract

Purpose: To develop an adaptive radiotherapy (ART) strategy based on in vivo dose verification using volumetric imaging, real‐time physiologically constrained deformable image registration (PC‐DIR) and high performance computation (HPC). Method and Materials: Comparison of delivered and planned dose distributions for patients undergoing radiation therapy, especially IMRT, can be used to estimate treatment outcome, and develop a successful ART strategy that accounts for patient positioning errors, organ deformation, physiological changes (i.e. tumor shrinkage, edema), and incorporating this back into the treatment planning. Using 4DCT imaging, we have developed a ART methodology based on 1) PC‐DIR for auto‐contouring; 2) automated internal target volume generation; 3) probability density function (PDF) for specific structures; and 4) graphics processor unit (GPU) based HPC for real‐time computation using NVIDIA 8800GTX. Results: Compared with the same algorithm without the PC constraint, PC‐DIR resulted in superior performance with up to 91% reduction in inverse consistency errors. The computer generated ITV yielded contours typically within 3mm of physician drawn contours, and also served as a check of physician drawn ITVs. The PDF was constructed for the ITV to determine the dose distribution based on spatial probability using time averaging over a respiratory cycle. GPU based registrations of 256×256×64 imaging volumes required 3.6 sec for 100 iterations, a 56X speedup compared with conventional CPU computing (i.e. dual core 2.4GHz CPU). Dose remapping and dose volume histogram computations were near real‐time (⩽3sec). Conclusion: We have developed key elements of a clinically implementable ART strategy, which include real‐time computations using GPU, and accurate and robust registrations based on PC‐DIR. These elements incorporate 4DCT imaging coupled with GPU based PC‐DIR and frequent conebeam CT (CBCT) verification. This methodology can exploit ongoing improvement in GPU hardware performance and CBCT image quality.

Similar Papers
  • Research Article

Cone-beam CT in an offline image guidance strategy: Margin and efficiency gains

  • Sep 01, 2004
  • International Journal of Radiation OncologyBiologyPhysics
  • D Lockman +3
  • PDF
  • Research Article

Pancreatic SABR using peritumoral fiducials, triggered imaging and breath-hold

  • Dec 21, 2023
  • Pathology and Oncology Research
  • Katalin Kisivan +11
  • Research Article
  • Citations2

SU-GG-T-20: GPU-Accelerated Auto-Segmentation for Online Adaptive Radiotherapy

  • Jun 01, 2010
  • Medical Physics
  • A Godley +3
  • Research Article
  • Citations27

An ex vivo study of automated motion artefact correction and the impact on cone beam CT image quality and interpretability.

  • Mar 22, 2018
  • Dentomaxillofacial Radiology
  • Rubens Spin-Neto +4
  • Research Article
  • Citations3

Advancing knowledge-based intensity modulated proton planning for adaptive treatment of high-risk prostate cancer

  • Oct 30, 2023
  • Medical Dosimetry
  • Casey L Johnson +8
  • Research Article
  • Citations6

Technical Note: Assessing the performance of monthly CBCT image quality QA.

  • Apr 24, 2019
  • Medical Physics
  • Ryan P Manger +3
  • Abstract
  • Citations8

A Leaning-Based Method to Improve Cone Beam CT Image Quality for Adaptive Radiation Therapy

  • Sep 23, 2017
  • International Journal of Radiation Oncology*Biology*Physics
  • X Yang +8
  • PDF
  • Research Article
  • Citations5

Image quality of 4D in-treatment CBCT acquired during lung SBRT using FFF beam: a phantom study

  • Sep 25, 2020
  • Radiation Oncology
  • Jihun Kim +5
  • Abstract
  • Citations1

Initial Experience Using Daily Artificial Intelligence-Assisted Adaptive Radiotherapy on Cone-Beam CT for Bladder Cancer

  • Oct 22, 2022
  • International Journal of Radiation Oncology*Biology*Physics
  • P.A Blumenfeld +8
  • Conference Article
  • Citations5

Performance Analysis of GPU Accelerators with Realizable Utilization of Computational Density

  • Jul 01, 2012
  • Justin W Richardson +2
  • Research Article

Patient With Post-operative Recurrent Pancreatic Cancer Treated With Cone Beam Computed Tomography-Guided Stereotactic Adaptive Radiotherapy: A Case Report

  • Dec 07, 2024
  • Cureus
  • Farnoush Forghani +5
  • Research Article
  • Citations24

Comparison of Cone Beam Computed Tomography and Multi Slice Computed Tomography Image Quality of Human Dried Mandible using 10 Anatomical Landmarks.

  • Jan 01, 2017
  • JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH
  • Samira Saati
  • Research Article
  • Citations26

Efficient methods for implementation of multi-level nonrigid mass-preserving image registration on GPUs and multi-threaded CPUs

  • Jan 06, 2016
  • Computer Methods and Programs in Biomedicine
  • Nathan D Ellingwood +3
  • Research Article

TU-AB-303-08: GPU-Based Software Platform for Efficient Image-Guided Adaptive Radiation Therapy

  • Jun 01, 2015
  • Medical Physics
  • S Park +7
  • Research Article
  • Citations28

Dosimetric Evaluation of Incorporating Patient Geometric Variations Into Adaptive Plan Optimization Through Probabilistic Treatment Planning in Head and Neck Cancers

  • Apr 05, 2018
  • International Journal of Radiation Oncology*Biology*Physics
  • Qiang Liu +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.