Subcutaneous chronic implantable defibrillation systems in humans

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The recent introduction of subcutaneous implantable cardioverter defibrillator (S-ICD) has raised attention about the potential of this technology for clinical use in daily clinical practice. We review the methods and results of the four studies conducted in humans for approval of this innovative technology for daily practice. Two studies using a temporary S-ICD system (acute human studies) were conducted to search for an appropriate lead configuration and energy requirements. For this purpose, 4 S-ICD configurations were tested in 78 patients at the time of transvenous (TV)-ICD implantation. The optimal configuration was tested in 49 more patients to comparatively assess the subcutaneous defibrillation threshold (S-DFT) versus the standard TV-ICD. Long-term implants were evaluated in 55 patients using an implanted system (chronic human study). The acute humans studies led to an optimal S-ICD configuration comprising a parasternal electrode and left anterolateral thoracic pulse generator. Both configurations successfully terminated 98% of induced ventricular fibrillation (VF), but significantly higher energy levels were required with S-ICD than with TV-ICD systems (36.6 ± 19.8 J vs. 11.1 ± 8.5 J). In the chronic study, all 137 VF episodes induced at time of implant were detected with a 98% conversion rate. Two pocket infections and four lead revisions were required during 10 ± 1 months of follow-up. During this period, survival was 98%, and 12 spontaneous ventricular tachyarrhythmias were detected and treated by the device. These data show that the S-ICD systems here consistently detected and converted VF induced at time of implant as well as sustained ventricular tachyarrhythmias occurring during follow-up (248).

Similar Papers
  • Research Article
  • Citations1

Five year outcomes of the subcutaneous implantable cardioverter-defibrillator EFFORTLESS (evaluation of factors impacting clinical outcome and cost effectiveness of the S-ICD) registry

  • May 24, 2021
  • EP Europace
  • P Lambiase +12
  • Research Article

Innovations in cardiac device therapy in the era of advanced rhythm management: implantable defibrillators and conduction system pacing.

  • Jan 19, 2026
  • Heart (British Cardiac Society)
  • Margarida Pujol-Lopez +2
  • Research Article

Implantation of an S-ICD in a Patient with a DDD Pacemaker and Congenitally Corrected Transposition of the Great Arteries

  • Feb 01, 2021
  • Cardiovascular Innovations and Applications
  • Yu Zhang +4
  • Research Article

A new algorithm to reduce T-wave over-sensing based on phase space reconstruction in S-ICD system

  • Aug 26, 2021
  • Computers in Biology and Medicine
  • Hanjie Chen +4
  • Research Article

Abstract 13503: Efficacy of Subcutaneous Implantable Cardioverter Defibrillator Defibrillation Testing in Hypertrophic Cardiomyopathy Patients at High Risk of Sudden Cardiac Death

  • Nov 11, 2016
  • Circulation
  • Niccolo’ Maurizi +17
  • Conference Article
  • Citations1

Computer simulation of defibrillations using subcutaneous implantable cardioverter-defibrillators

  • Oct 01, 2014
  • Xin Zhu +2
  • Research Article

How the Subcutaneous Implantable Cardioverter Defibrillator Works

  • Apr 15, 2014
  • Cardiac Electrophysiology Clinics
  • Ian Crozier +3
  • Research Article
  • Citations21

How the S-ICD (subcutaneous implantable cardiac defibrillator) senses cardiac signals to minimize cardiac over-sensing and maximize rhythm discrimination

  • Aug 18, 2018
  • Journal of Electrocardiology
  • Amy Brisben
  • Research Article
  • Citations18

The Entirely Subcutaneous Defibrillator – A New Generation and Future Expectations

  • Jan 01, 2015
  • Arrhythmia & Electrophysiology Review
  • Hussam Ali +2
  • Research Article

Dosimetric feasibility of stereotactic arrhythmia radioablation for ventricular tachycardia in patients with a subcutaneous implantable cardioverter defibrillator

  • Jul 01, 2025
  • Physics and Imaging in Radiation Oncology
  • Lena Kaestner +17
  • Research Article

Left ventricular assist device in the presence of subcutaneous implantable cardioverter defibrillator: data from a multicenter experience

  • May 24, 2024
  • Europace
  • F Migliore +14
  • Research Article
  • Citations18

Long-term results of combined cardiac contractility modulation and subcutaneous defibrillator therapy in patients with heart failure and reduced ejection fraction.

  • Apr 01, 2018
  • Clinical Cardiology
  • Susanne Röger +10
  • Research Article

Early Failure of Subcutaneous ICD in a Patient With a Variant of Rapidly Progressive ARVC

  • Jul 01, 2025
  • JACC Case Reports
  • Alexandre Cinq-Mars +9
  • Research Article

Subcutaneous intracardiac defibrillator (s-icd): the better icd-alternative in athletes with arrhythmogenic risks?

  • Feb 01, 2022
  • Deutsche Zeitschrift für Sportmedizin/German Journal of Sports Medicine
  • Jb Dahm +1
  • Research Article
  • Citations3

Personalized subcutaneous implantable cardioverter-defibrillator sensing vectors generated by mathematical rotation increase device eligibility whilst preserving device performance

  • Jan 11, 2022
  • EP Europace
  • Benedict M Wiles +9
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.