Abstract

The subsynchronous resonance (SSR) is an important problem in the power system, and especially the series compensated transmission lines may cause SSR in the turbine generators, such that it leads to the electrical instability at subsynchronous frequencies and potential turbine-generator shaft failures. Taking the Vietnamese Vungang thermal plants as an example, a shaft failure of Vungang I thermal power unit has occurred on November 24, 2015, due to SSR. The main cause for this failure is a resonance caused by the series capacitors on the 500 kV grid. This paper analyzes the SSR based on the location of shaft cracks and turbine generator mode shape for Vungang I and II thermal power plants. On the basis of that, it develops a novel control strategy for each Flexible AC Transmission system (FACTS) device as the thyristor controlled series compensator (TCSC), static VAR compensator (SVC), and static synchronous compensator (STATCOM). Then they are comparable to one another in order to choose a feasible solution for mitigating the SSR. The effectiveness of the proposed control strategy is verified via time domain simulation of the Vietnamese 500/220 kV transmission system using EMTP-RV and PSS/E programs. The obtained results show that the proposed strategy for SVC can be applied to immediately solve the difficulties encountering in the Vietnamese power system.

Loading PDF

Similar Papers
  • Conference Article
  • Citations3

Review and Analysis of Techniques to Mitigate Sub Synchronous Resonance using FACTS Devices

  • May 05, 2022
  • G Ramya +4
  • Research Article

Mitigating Subsynchronous Resonance in Doubly Fed Wind Turbine Induction Generator Using FACTS Devices: A Comparative Case Study

  • Dec 24, 2024
  • International Journal of Robotics and Control Systems
  • Bui Thi Hoa Phuong +3
  • PDF
  • Research Article
  • Citations3

Mitigation of SSR with STATCOM using Subsynchronous Damping Controller on Series-Compensated Transmission Line

  • Dec 15, 2016
  • Indian Journal of Science and Technology
  • Natasha Singla +2
  • Conference Article
  • Citations11

Analysis of SSR Mitigation Using Gate Controlled Series Capacitors

  • Jun 16, 2005
  • F Jesus +3
  • Research Article
  • Citations15

Comparison of BBO, WIPSO & PSO Techniques for the Optimal Placement of FACTS Devices to Enhance System Security

  • Jan 01, 2016
  • Procedia Technology
  • K Kavitha +1
  • Book Chapter
  • Citations3

Improvement of system stability margins using coordination control of Static Var Compensator (SVC) and Thyristor Controlled Series Capacitor (TCSC)

  • Sep 11, 2012
  • Venu Yarlagadda +2
  • Research Article

A Peer Review on FACTS Controllers in Electrical Power Systems

  • Nov 20, 2025
  • International Journal of Innovative Science and Research Technology
  • D Chaithanya +5
  • Conference Article
  • Citations44

SSR analysis of a DFIG-based wind farm interfaced with a gate-controlled series capacitor

  • Mar 01, 2014
  • Hossein Ali Mohammadpour +2
  • Research Article
  • Citations31

Comparison of computational intelligence algorithms for loadability enhancement of restructured power system with FACTS devices

  • Feb 27, 2012
  • Swarm and Evolutionary Computation
  • S Nagalakshmi +1
  • Conference Article
  • Citations26

Mitigation of subsynchronous oscillations by 48-pulse VSC STATCOM using remote signal

  • Jun 01, 2009
  • A Salemnia +2
  • Conference Article
  • Citations1

Subsynchronous Resonance Mitigation in SMIB System Using GCSC and TCSC with Conventional and Fuzzy Logic Controllers

  • Jan 05, 2023
  • J Sreeranganayakulu +2
  • Research Article
  • Citations41

Basic aspects of applying SVC's to series-compensated AC transmission lines

  • Jul 01, 1990
  • IEEE Transactions on Power Delivery
  • E.V Larsen +4
  • Conference Article
  • Citations2

Remote signal STATCOM controller for mitigation of sub-synchronous resonance in series compensated type 3 wind farm

  • Aug 01, 2017
  • Gajanan V Gotmare +1
  • Conference Article
  • Citations16

A comparison between SVC and STATCOM in flicker mitigation of electric arc furnace using practical recorded data

  • Nov 01, 2015
  • Haidar Samet +1
  • Research Article
  • Citations27

State estimation of power systems containing facts controllers

  • Jan 08, 2011
  • Electric Power Systems Research
  • A Zamora-Cárdenas +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.