• Home
  • Search
  • SuperFGD prototype time resolution studies
  • Open Access IconOpen Access
  • Cite Icon12
  • https://doi.org/10.1088/1748-0221/18/01/p01012Copy DOI Icon

SuperFGD prototype time resolution studies

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The SuperFGD detector will be a novel and important upgrade to the ND280 near detector for both the T2K and Hyper-Kamiokande projects. The main goal of the ND280 upgrade is to reduce systematic uncertainties associated with neutrino flux and cross-section modeling for future studies of neutrino oscillations using the T2K and Hyper-Kamiokande experiments. The upgraded ND280 detector will be able to perform a full exclusive reconstruction of the final state from neutrino-nucleus interactions, including measurements of low momentum protons, pions and for the first time, event-by event measurements of neutron kinematics. Precisely understanding the time resolution is critical for the neutron energy measurements and hence an important factor in reducing the systematic uncertainties. In this paper we present the results of time resolution measurements made with the SuperFGD prototype that consists of 9216 plastic scintillator cubes (cube size is 1 cm3) readout with 1728 wavelength-shifting (WLS) fibers along the three orthogonal directions. We used data from a muon beam exposure at CERN. A time resolution of 0.97 ns was obtained for one readout channel after implementing the time calibration with a correction for time-walk effects. The time resolution improves with increasing energy deposited in a scintillator cube, improving to 0.87 ns for large pulses. Averaging two readout channels for one scintillator cube further improves the time resolution to 0.68 ns implying that signals in different channels are not synchronous. In addition the contribution from the time sampling interval of 2.5 ns is averaged as well. Most importantly, averaging time values from N channels improves the time resolution by ∼ 1/√(N). For example, averaging the time from 2 scintillator cubes with 2 fibers each improves the time resolution to 0.47 ns which is much better than the intrinsic electronics time resolution of 0.72 ns in one channel due to the 2.5 ns sampling window. This indicates that a very good time resolution should be achievable for neutrons since neutron recoils typically interact with several scintillator cubes and in addition produce larger signal amplitudes than muons. Measurements performed with a laser and a wide-bandwidth oscilloscope in which the contribution from the electronics time sampling window was removed demonstrated that the time resolution obtained with the muon beam is not far from the theoretical limit. The intrinsic time resolution of a scintillator cube and one WLS fiber is about 0.67 ns for signals of 56 photo electrons which is typical for minimum ionizing particles.

Similar Papers
  • Research Article
  • Citations231

Single optical photon detection with a superconducting tunnel junction

  • May 01, 1996
  • Nature
  • A Peacock +11
  • Research Article
  • Citations281

Study of MRPC technology for BESIII endcap-TOF upgrade

  • Jul 03, 2017
  • Radiation Detection Technology and Methods
  • Xin Li +20
  • Research Article
  • Citations2

The FFIS spectrometer for determination of fission fragment mass distribution with the energy–velocity method

  • Aug 06, 2022
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • Chao Liu +7
  • Book Chapter
  • Citations2

Chapter 76 - Transient two-dimensional infrared spectroscopy-towards measuring ultrafast structural dynamics

  • Jan 01, 2004
  • Femtochemistry and Femtobiology
  • Jens Bredenbeck +2
  • Research Article
  • Citations13

Development of a Thin, Double-Sided Alpha/Beta Detector for Surface-Contamination Measurement

  • Apr 01, 2016
  • IEEE Transactions on Nuclear Science
  • Y Ifergan +13
  • Conference Article

Proof-of-principle of a new geometry for sampling calorimetry

  • Nov 01, 2014
  • G Dissertori +11
  • Research Article
  • Citations1

Selecting and designing the front-end amplifier for high-gain photomultiplier detectors with optimal timing performance

  • Oct 06, 2018
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • G Matarrese +4
  • Research Article
  • Citations113

Detector development for microPET II: a 1 μl resolution PET scanner for small animal imaging

  • Oct 05, 2001
  • Physics in Medicine & Biology
  • A Chatziioannou +3
  • Conference Article

Experimental and simulation results with the Depth-encoding Anger Detector

  • Oct 19, 2003
  • K.L Matthews +4
  • Conference Article
  • Citations4

The BC-704 scintillation screen with light readout by wavelength shifting fibers as a highly efficient neutron detector

  • Oct 01, 2011
  • J Iwanowska +5
  • Conference Article
  • Citations8

Capacitor based multiplexing circuit for silicon photomultiplier array readout

  • Nov 01, 2014
  • Xishan Sun +2
  • Conference Article
  • Citations16

CeBr3 for Time-of-Flight PET

  • Jan 01, 2006
  • Jarek Glodo +7
  • Single Report
  • Citations1

High-speed digitization readout of silicon photomultipliers for time of flight positron emission tomography

  • Feb 01, 2011
  • A Ronzhin +10
  • Research Article
  • Citations12

A fast coincidence preamplifier for solid state radiation detectors

  • Dec 01, 1963
  • Nuclear Instruments and Methods
  • H Wahl
  • Research Article

Prototype performance of novel muon telescope detector at STAR

  • Jun 01, 2011
  • Indian Journal of Physics
  • L Ruan +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.