• Home
  • Search
  • Support vector machine for arrhythmia discrimination with TCI feature selection
  • Cite Icon2
  • https://doi.org/10.1109/iccsn.2011.6014230Copy DOI Icon

Support vector machine for arrhythmia discrimination with TCI feature selection

  • May 1, 2011
  • Chunyun Zhang +4 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Ventricular fibrillation (VF) is a malignant arrhythmia, which belongs to complex and nonlinear signals. To realize the detection of ventricular fibrillation, a new algorithm, which was based on the improved threshold crossing interval (TCI) algorithm and Support vector machine (SVM), was proposed in this paper. The SWM has great advantages in processing classification and pattern recognition. In this paper, 4-s-sliding-window technology and the improved TCI algorithm are applied to extract features of electrocardiogram (ECG). The improved TCI algorithm was implemented as follows: firstly, the average threshold crossing interval value of the middle 2s was calculated by using absolute threshold at each 4-s-sliding-window; secondly, the feature parameter (TCI value) was input to a pre-designed binary classification support vector machine; lastly, the classification was accomplished. For evaluating the reliability of the new algorithm, both MIT-BIH arrhythmia database and CU ventricular tachyarrhythmia database were used to test. By comparing the sensitivity, specificity, positive predictability and accuracy with other well known methods, the conclusion was made that this method is superior to other methods. This new algorithm is easier to implement and has greater advantages in real-time execution. These advantages make it more suitable in real time ECG monitoring and defibrillator.

Similar Papers
  • Conference Article
  • Citations5

Classification of energy tree species using support vector machines

  • Jun 01, 2014
  • Peter Burai +3
  • Research Article
  • Citations21

Implantable Defibrillators With Enhanced Detection Algorithms: Detection Performance and Safety Results from the PainFree SST Study

  • Mar 25, 2014
  • Pacing and Clinical Electrophysiology
  • Christian G Wollmann +7
  • PDF
  • Research Article
  • Citations50

Arrhythmia Evaluation in Wearable ECG Devices.

  • Oct 25, 2017
  • Sensors
  • Muammar Sadrawi +8
  • Research Article
  • Citations3

Support Vector Machine Algorithm for Real-Time Detection of VF Signals

  • Jan 01, 2011
  • Procedia Environmental Sciences
  • Chunyun Zhang +4
  • Research Article
  • Citations101

Improved Protein Secondary Structure Prediction Using Support Vector Machine With a New Encoding Scheme and an Advanced Tertiary Classifier

  • Dec 01, 2004
  • IEEE Transactions on Nanobioscience
  • H.-J Hu +3
  • Research Article
  • Citations41

Use of approximate entropy measurements to classify ventricular tachycardia and fibrillation

  • Jan 01, 1998
  • Journal of Electrocardiology
  • Stephanie A Caswell Schuckers
  • Conference Article
  • Citations1

Developing Support Vector Machine Prediction Capabilities of Uranium Enrichment Based on Gamma-Gamma Coincidence Signatures

  • Oct 01, 2017
  • Adam Drescher +2
  • PDF
  • Research Article
  • Citations7

Indoor versus outdoor scene recognition for navigation of a micro aerial vehicle using spatial color gist wavelet descriptors

  • Nov 26, 2019
  • Visual Computing for Industry, Biomedicine, and Art
  • Anitha Ganesan +1
  • Research Article
  • Citations22

Determining optimal bead central angle by applying machine learning to wire arc additive manufacturing (WAAM)

  • Dec 07, 2023
  • Heliyon
  • Dong-Ook Kim +2
  • PDF
  • Research Article
  • Citations79

Transfer Deep Learning Along With Binary Support Vector Machine for Abnormal Behavior Detection

  • Jan 01, 2020
  • IEEE Access
  • Ahlam Al-Dhamari +2
  • Conference Article
  • Citations1

Fusing binary support vector machines (SVM) into multiclass SVM

  • Nov 13, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Zilu Ying +2
  • Research Article
  • Citations21

Proposition of novel classification approach and features for improved real-time arrhythmia monitoring

  • Jun 08, 2016
  • Computers in Biology and Medicine
  • Yoon Jae Kim +3
  • Conference Article
  • Citations7

Multi-classification of cardiac diseases utilizing wavelet thresholding and support vector machine

  • Jan 01, 2019
  • AIP conference proceedings
  • Jianqing Li +2
  • Research Article
  • Citations19

An external automatic device to detect ventricular fibrillation.

  • May 01, 1986
  • European heart journal
  • C M Jack +5
  • Research Article
  • Citations38

Complexity measure and complexity rate information based detection of ventricular tachycardia and fibrillation.

  • Sep 01, 2000
  • Medical & Biological Engineering & Computing
  • H -X Zhang +2
Cactus Communications logo